Datasheet sections

  • 1 Electrical ratings
  • 2 Electrical characteristics
  • 2.1 Electrical characteristics (curves)
  • 3 Test circuits
  • 4 Package mechanical data
  • 5 Packaging mechanical data
  • 6 Revision history

Features

Type V DSS RDS(on) max I D STD27N3LH5 30 V 0.019 Ω 27 A STP27N3LH5 30 V 0.020 Ω 27 A STU27N3LH5 30 V 0.020 Ω 27 A IPAK DPAK TO-220 1 sc08440 D (TAB or 2) G (1) S (3) Table 1. Device summary

1 Electrical ratings

Table 2. Absolute maximum ratings

  1. Pulse width limited by safe operating area

Table 3. Thermal resistance

2 Electrical characteristics

Table 4. Static Table 5. Dynamic

Table 6. Switching on/off (resistive load) Table 7. Source drain diode

  1. Pulsed: pulse duration = 300 µs, duty cycle 1.5 %

2.1 Electrical characteristics (curves)

Figure 2. Safe operating area for TO-220 Figure 3. Thermal impedance for TO-220 Figure 4. Safe operating area for DPAK, IPAK Figure 5. Thermal impedance for DPAK, IPAK Figure 6. Output characteristics Figure 7. Transfer characteristics

Figure 14. Source-drain diode forward

3 Test circuits

Figure 15. Switching times test circuit for Figure 16. Gate charge test circuit Figure 17. Test circuit for inductive load Figure 18. Unclamped inductive load test Figure 19. Unclamped inductive wavefor m Figure 20. Switching time waveform

Figure 21. Gate charge waveform

4 Package mechanical data

In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK is an ST trademark.

Table 8. DPAK (TO-252) mechanical data

Table 9. IPAK (TO-251) mechanical data

Figure 24. IPAK (TO-251) drawing

Table 10. TO-220 type A mechanical data

Figure 25. TO-220 type A drawing

5 Packaging mechanical data

Table 11. DPAK (TO-252) tape and reel mechanical data

6 Revision history