Features

  • High hFE : hFE=160~320
  • Low collector saturation voltage : VCE(sat)=0.5V(MAX.)

Ordering Information

A b s o l u t e m a x i m u m r a t i n g s (Ta=25°C) Characteristic Symbol Ratings Unit Collector-Base voltage V CBO 45 V Collector-Emitter voltage V CEO 40 V Emitter-Base voltage V EBO 5 V IC 1 A(DC) Collector current ICP* 2 A(Pulse) PC 0.5 Collector power dissipation PC ** 1 W Junction temperature T J 150 °C Storage temperature T stg -55~150 °C * : Single pulse, tp= 300 ㎲ ** : When mounted on ceramic substrate(250 ㎟×0.8t) Type No. Marking Package Code STC201F C201 YWW SOT-89 C201: DEVICE CODE, YWW(Y : Year code, WW : Weekly code)

E l e c t r i c a l C h a r a c t e r i s t i c s (Ta=25°C) Characteristic Symbol Test Condition Min. Typ. Max. Unit Collector-Base breakdown voltage BV CBO IC=100μA, IE=0 45 - - V Collector-Emitter breakdown voltage BV CEO I C=1mA, IB=0 40 - - V Emitter-Base breakdown voltage BV EBO IE=10μA, IC=0 5 - - V Collector cut-off current I CBO V CB=45V, IE=0 - - 0.1 μA Emitter cut-off current I EBO V EB=5V, IC=0 - - 0.1 μA DC current gain hFE * VCE=1V, IC=100mA 160 - 320 - Collector-Emitter saturation voltage V CE(sat) I C=500mA, IB=50mA - - 0.5 V Transition frequency f T V CE=5V, IC=10mA - 150 - MHz Collector output capacitance C ob V CB=10V, IE=0, f=1MHz - 8 - pF * Note 1) hFE Rank : 160~320 only * Note 2) Pulse Tester : Pulse Width ≤300μs, Duty Cycle ≤2.0%

Electrical Characteristic Curves Fig. 2 I C - VBE Fig. 5 IC - VCE Fig. 1 P C - Ta Fig. 6 hFE - I C Fig. 3 V CE(sat) - IC F i g . 4 IC - VCE

Fig. 8 hFE - I C Fig. 9 Cob - V CB Fig. 11 Safe operating Area 2× 18 Fig. 7 hFE - I C F i g . 1 0 fT - IC

Outline Dimension(mm) ※Recommend PCB solder land [Unit: mm]

The AUK Corp. products are intended for the use as components in general electronic equipment (Office and co mmunication equipment, m easuring equipment, home appliance, etc.). Please make sure that you consult with us before you use these AUK Corp. products in equipments which require high quality and / or reliability, and in equipments which could have major impact to th e welfare of human life(atomi c energy control, airplane, spaceship, transportation, co mbustion control, all types of safety device, etc.). AUK Corp. cannot accept liability to any damage which may occur in case these AUK Corp. products were used in the mentioned equi pments without prior consultation with AUK Corp.. Specifications mentioned in this publication are subject to change without notice.