Features
- High collector-emitter voltage : VCEO=-300V
- Complementary pair with STC42N
Ordering Information
Type NO. Marking Package Code STA92N STA92 T0-92N O u t l i n e D i m e n s i o n s u n i t : mm SSeemmiiccoonndduuccttoorr PIN Connections 1. Emitter 2. Base 3. Collector 3.09~3.29 0.40 Max. 1.27 Typ. 4.20~4.40 0.52 Max. 2.25 Max. 13.50~14.50 4.20~4.40 2.14 Typ. 0.90 Max.
3.55 Typ
A b s o l u t e M a x i m u m R a t i n g s (Ta=25°C) Characteristic Symbol Rating Unit Collector-base voltage V CBO -300 V Collector-emitter voltage V CEO -300 V Emitter-base voltage V EBO -6 V Collector current I C -500 mA Collector power dissipation P C 400 mW Junction temperature T J 150 °C Storage temperature range T stg -55~150 °C E l e c t r i c a l C h a r a c t e r i s t i c s (Ta=25°C) Characteristic Symbol Test Condition Min. Typ. Max. Unit Collector-emitter breakdown voltage BV CEO I C=-1mA, IB=0 -300 - - V Collector cut-off current I CBO V CB=-300V, IE=0 - - -0.1 µA Emitter cut-off current I EBO V EB=-6V, IC=0 - - -0.1 µA DC current gain hFE * VCE=-10V, IC=-30mA 40 - - - Collector-emitter saturation voltage VCE(sat) * IC=-20mA, IB=-2mA - - -0.5 V Base-emitter saturation voltage VBE(sat) * IC=-20mA, IB=-2mA - - -0.9 V Base-emitter voltage V BE V CE=-10V, IC=-30mA - -0.7 -0.9 V Transition frequency f T V CE=-20V, IC=-10mA - 80 - MHz Collector output capacitance C ob V CB=-20V, IE=0, f=1MHz - 3 - pF * : Pulse Tester : Pulse Width≤300 ㎲, Duty Cycle≤2.0% STA92N
Electrical Characteristic Curves Fig. 2 V CE(sat),VBE(sat) - IC Fig. 4 C ob - VCB Fig. 1 h FE - IC Fig. 3 f T - IC The AUK Corp. products are intended for the use as components in general electronic equipment (Office and communication equipment, measuring equipment, home appliance, etc.). Please make sure that you consult with us before you use these AUK Corp. products in equipments which require high quality and / or reliability, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, transportation, combustion control, all types of safety device, etc.). AUK Corp. cannot accept liability to any damage which may occur in case these AUK Corp. products were used in the mentioned equipments without prior consultation with AUK Corp.. Specifications mentioned in this publication are subject to change without notice.