Features

  • Standard “hockey puck” package.
  • Enhanced noise immunity (designed to meet level 3 requirements of European EMC Directive).
  • LED indicator.
  • Floating terminal design.
  • Low cost snubberless triac outputs.
  • 10A & 25A rms versions.
  • AC & DC input versions.
  • 4000V rms isolation. Input Specifications Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. SSRT -240A10 SSRT -240A25 SSRT -240D10 SSRT -240D25 Parameter Control Voltage Range V Must Release Voltage V (Min.) Input Current (Max.) AC Input/AC Output 90 - 280VAC 10VAC 90VAC 8.5mA 3 - 32VDC 3VDC 1VDC 14mA DC Input/AC Output Must Operate Voltage V (Max.) IN IN(OP) IN(REL) SSRT series “Hockey Puck” Solid State Relay With Snubberless T riac Output

P&B Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Operating Diagrams ZERO VOLTAGE CIRCUIT EQUIVALENT CIRCUIT ONLY CONSTANT CURRENT DC INPUT OUTPUT ZERO VOLTAGE CIRCUIT EQUIVALENT CIRCUIT ONLY AC INPUT OUTPUT+ Outline Dimensions 1.750 (44.45) .785 (19.94) .250 (6.35) 1.100 (27.94).470 (11.9) 2.250 (57.15) 1.850 (47.0) 1.700 (43.18) 1.000 (25.4) .875 (22.23) .870 (22.1) LED INDICATOR Output Specification (@ 25°C, unless otherwise specified) Electrical Characteristics (Thermal Derating Curves) *See Derating Curves Parameter Conditions Units Load Voltage Range V Repetitive Blocking Voltage (Min.) Thermal Resistance, Junction to Case (R ) (Max.) I t Rating A Sec. V rms ° C/W V/µs ms msTurn-Off Time (Max.) I = Max. θ Turn-On Time (Max.) L L 24 - 280 0.5 - 1.0 SSRT-240A10 & SSRT-240D10 SSRT-240A25 & SSRT-240D25 Single Cycle Surge Current (Min.) Load Current Range I * Leakage Current (Off-State) (Max.) Static dv/dt (Off-State) (Min.) Load Power Factor Rating L t = 8.3 ms 2 f = 60 Hz. f = 60 Hz. I = Max.L f = 60 Hz. V = Nom. (120 or 240 V rms) V peak A rms A peak mA rms On-State Voltage Drop (Max.) V peak 500 8.3 for DC input types, 20 for AC input types 100 250 .1 - 10 .1 - 25 - 600 8.3 for DC input types, 30 for AC input types 41 240 L 2.2 1.7j-c Resistive 1.5 1.3 Heatsink Recommendations

  • We recommend that solid state relay modules be mounted to a heatsink sufficient to maintain the module ’s base temperature at less than 85°C under worst case ambient temperature and load conditions.
  • The heatsink mounting surface should be a smooth (30-40 micro-inch finish), flat (30-40 micro-inch flatness across mating area ), un-painted surface which is clean and free of oxidation.
  • An even coating of thermal compound (Dow Corning DC340 or equivalent) should be applied to both the heatsink and module mounti ng surfaces and spread to a uniform depth of .002” to eliminate all air pockets.
  • The module should be mounted to the heatsink using two#10 screws. 10A Units 25A Units