Features
- DIN mount design with integral heatsink.
- Choice of 45, 55 or 65A rms inverse-parallel connected SCR output.
- 48 - 660VAC output.
- 4 -32VDC or 90 - 140Vrms input control.
- 4,000V rms optical isolation.
- Green LED input status indicator.
- Finger-safe (IP20) screw clamp terminals for load and control.
- Ground terminal. Input Specifications Parameter Conditions Control Voltage Range V Must Release Voltage V (Min.) Input Current (Max.) 4.0 - 32 VDC
4.0 VDC
1.0 VDC
Must Operate Voltage V (Min.) IN IN IN(OP) IN(REL) DC Control Units 90 - 140 Vrms
90 Vrms
10 Vrms
@ 25°C Reverse Voltage V (Max.) 32 VDC—@ 25°C @ 25°C @ 25°C @ 25°C Input Current (Typ.) 14 mA @ 5 VDC15 mA @ 120 Vrms@ 25°C Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. SSRM-600A45 SSRM-600A55 SSRM-600A65 SSRM-600D45 SSRM-600D55 SSRM-600D65 File E29244 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to confirm the product meets the requirements for a given application. SSRM series 45-65A DIN Mount Solid State Relay With Paired SCR Output, Integral Heatsink
SSRM Series Solid State Relays Dimensions are in inches over (millimeters) unless otherwise specified. Dimensions are shown for reference purposes only. Specifications and availability subject to change. South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 3.0 (76.2) 2.5 (63.5) 3.0 (76.2) 3.5 (88.9) 4.3 (109.2) (22.9) 1.75 (44.5) 0.75 (19.1) 1.0 (25.4) OUTPUT INPUT IN PUT STATU S MOUNTING HOLE 0.17 (4.3) DIA. BLACK ANODIZED ALUMINUM HEATSINK MOUNTING SLOT Outline Dimensions Electrical Characteristics (Thermal Derating Curves) *See Thermal Derating Curves. Parameter Conditions Units 45A Rated Units 65A Rated Units Load Voltage Range V Repetitive Blocking Voltage (Min.) I t Rating (Max.) A Sec. V rms V/µs ms ms Turn-Off Time (Max.) I = Max. Turn-On Time (Max.) L L 48 - 660 Single Cycle Surge Current (Min.) Load Current Range I * Leakage Current (Off-State) (Max.) Static dv/dt (Off-State) (Min.) Load Power Factor Rating (Min.) L t = 8.3 ms 2 f = 60 Hz. f = 47 - 63 Hz. f = 60 Hz. I = Max.L f = 60 Hz. V = 600Vrms V peak A rms A peak mA rms On-State Voltage Drop (Max.) V peak 1,200 0.25 - 65.0 ±1200 6,000 1.0 1.7 500 L 0.5 55A Rated Units 48 - 660 1,000 0.25 - 55.0 ±1200 4,150 1.0 1.7 500 0.5 48 - 660 8.3 for DC Input Models, 10.0 for AC Input Models 8.3 for DC Input Models, 40.0 for AC Input Models 625 0.15 - 45.0 ±1200 1,620 1.0 Thermal Resistance Junction to Case R (Max.) °C/W 0.28 0.310.63 1.7 500 0.5 V = Max.L θ J–C Output Specifications (@ 25° C, unless otherwise specified) Ambient Temperature (ºC) Output Current (Arms) 45 A Ambient Temperature (ºC) Output Current (Arms) 55 A Ambient Temperature (ºC) Output Current (Arms) 65 A 50 60 70 8020 30 4010 50 60 70 8020 30 4010 50 60 70 8020 30 4010 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this document, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult Tyco Electronics for the latest dimensions and design specifications. Recommended Torque Range for Terminal Screws: Control: 5 - 6 in lb (0.6 - 0.7 Nm). Output: 10 - 15 in lb (1 .1 - 1 .7 Nm). Catalog 8-1773454-5 Issued 4-09 www.tycoelectronics.com © 2009 by Tyco Electronics Corporation. All Rights Reserved. TE logo and Tyco Electronics are trademarks.