SSRK TEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Features

  • Narrow (22.5mm), DIN mount design with integral heatsink.
  • Choice of 10, 20 or 30A rms inverse-parallel connected SCR output.
  • 24-240VAC and 48-660VAC output types.
  • 3 - 32VDC, 4 - 32VDC or 90 - 280Vrms input control.
  • 4000V rms optical isolation.
  • Green LED input status indicator.
  • Finger-safe (IP20) screw clamp terminals for load and control.
  • Ground terminal. Parameter Conditions AC Control Units DC Control Units

240 V 600V

Control Voltage Range VIN @25°C 90 - 280 Vrms 3 -32 VDC 4 -32 VDC Must Operate Voltage VIN(OP) (Min.) @25°C 90 Vrms 3 VDC 4 VDC Must release Voltage VIN(REL) (Min.) @25°C 10 Vrms 1 VDC 1 VDC Input Current Range(Typ.) @25°C 7.5mA @ 120 Vrms, 16mA @ 240 Vrms 18mA @ 5Vdc 9.5 - 30 mA File E29244 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. 10-30A DIN Mount Solid State Relay With Paired SCR Output, Integral Heatsink Typical Part Number > SSRK –600 A 1. Basic Series: SSRK = Slim Solid State Relay with Integral Heatsink for DIN Rail Mounting 2. Line Voltage: 240 = 24 - 240 VAC 600 = 48 - 660 VAC 3. Input Type & Voltage: A = 90 - 280 VAC D = 3 - 32VDC for 240V / 4 - 32VDC for 600V

Ordering Information

02-2018, Rev. 0218 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. Potter & Brumfield

Output Specifications (@ +25˚C unless otherwise specified) Parameter Conditions Nom. Line Voltage Units 10A Rated Units 20A Rated Units 30A Rated Units Load Voltage VL f = 47 - 63Hz

240 V model V rms 24 - 240 24 - 240 24 - 240

600 V model V rms 48 - 660 48 - 660 48 - 660

Repetitive Blocking Voltage (Min.)

240 V model V peak 600 600 600

600 V model V peak 1200 1200 1200

Load Current IL* 240 V & 600 V model A rms 0.15 - 10 0.15 - 20 0.15 - 30 Single Cycle Surge Current (Min.)

240 V model A peak 83 300 800

600 V model A peak 300 300 800

Leakage Current (Off-State) (Max.) f = 60Hz. - VL = 600Vrms 240 V & 600 V model mA rms 5 5 5 On-State Voltage Drop (Max.) IL=Max. 240 V model V peak 1.8 1.8 1.8 600 V model V peak 1.6 1.6 1.8 Static dv / dt (Off-State) (Min.) VL=Max.

240 V model V/μs 200 300 500

600 V model V/μs 300 300 500

Turn-On Time (Max.) f = 60Hz.

240 V & 600 V model ms 10 for DC Input Models, 40 for AC Input Models

Turn-Off Time (Max.) 240 V & 600 V model ms 10 for DC Input Models, 80 for AC Input Models I²t Rating (Max.) t = 8.3 ms

240 V model A²s 41 510 3745

600 V model A²s 510 510 3745

Electrical Characteristics (Thermal Derating Curves) * See Derating curve SCR Output Modules Outline Dimensions Solid State Relay SSRK Series (Continued) 02-2018, Rev. 0218 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. Potter & Brumfield