65 WATTS

FEATURES: OPEN FRAME CHASSIS/COVER SAFETY SPECIFICATIONS General Protection Class: I Overvoltage Category: II Pollution Degree: 2 Underwriters Laboratories File E137708 UL 60950-1 2nd Edition, 2007 CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition CB Reports/Certificates (including all National and Group Deviations) IEC 62368-1:2014 2ND Edition TUV SUD America EN 62368-1:2014 2ND Edition Low Voltage Directive RoHS Directive (Recast) (2014/35/EU of February 2014) (2015/863/EU of March 2015) Electrical Equipment (Safety) Regulations 2016 SI No. 1101 Restriction of the Use of Certain Hazardous Substances in EEE Regulations 2012 SI No. 3032 + 2019 SI No.492 MODEL LISTING MODEL NO. OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 SRW-65-4001 +5V/5A -5V/3A +12V/2A -12V/2A SRW-65-4002 +5V/5A +12V/1A +12V/2A -12V/2A SRW-65-4003 +5V/5A +24V/1A +12V/2A -12V/2A SRW-65-4004 +5V/5A -5V/3A +15V/2A -15V/2A SRW-65-4005 +5V/5A +24V/1A +12V/2A -5V/2A SRW-65-4006 +5V/5A +24V/1A +15V/2A -15V/2A SRW-65-4007 +5V/5A +26V/1A +15V/2A -15V/2A SRW-65-4008 +5V/5A +24V/1A +12V/2A -12V/2A SRW-65-4009 5V/7.5A +48V/.25A +15V/1A -15V/1A SRW-65-4104 +5V/4A 5V/.25A +15V/2.5A 24V/.50A SRW-65-3001 +5V/5A +12V/3A -12V/1A SRW-65-3002 +5V/7A +12V/2A -12V/2A SRW-65-3003 +5V/7A +15V/2A -15V/2A SRW-65-3004 +5V/5A -5V/4A +12V/2A SRW-65-2002 +5V/7A +12V/3A SRW-65-2003 +12V/3A -12V/2.5A SRW-65-2004 +15V/2.5A -15V/2A SRW-65-2005 +5V/7A +24V/1.5A SRW-65-2008 +6V/5A -6V/5A SRW-65-1001 +5V/13A SRW-65-1002 +12V/5.4A SRW-65-1003 +15V/4.3A SRW-65-1004 +24V/2.7A SRW-65-1005 +18V/3.6A SRW-65-1006 +24V/3.33A SRW-65-1104 +24V/3.33A SRW-65-1105 +21V/3.1A OUTPUT SPECIFICATIONS Total Output Power at 50°C 65W Output Voltage Centering Output 1:  1.0% (All outputs at 50% load) Output 2:  5.0% Output 3:  5.0% Output 4:  5.0% Output Voltage Adjust Range Output 1: 95 - 105% Load Regulation Output 1: 1.0% (10-100% load change) Output 2: 5.0% (20-80% load change) Output 3: 5.0% (20-80% load change) Output 4: 5.0% (20-80% load change) Source Regulation Outputs 1 – 4: 0.5% Cross Regulation Output 2: 5.0% (Output 1 load Output 3: 5.0% varied 50-100%) Output 4: 5.0% Output Noise Outputs 1 - 4: 1.0% Turn on Overshoot None Transient Response Outputs 1 – 4 Voltage Deviation 5.0% Recovery Time 2 mS Load Change 50% to 100% Output Overvoltage Protection (optional) Output 1: 110% to 150% Output Overpower Protection Outputs 1-4: 110% Min. Outputs cycle on/off, auto recovery Hold Up Time 16 mS min., 65W, 120V Input Start Up Time 1 Second INPUT SPECIFICATIONS Source Voltage 85 – 264 Volts AC Frequency Range 47 – 63 Hz Source Current True RMS Peak Inrush 1.5A at 85V Input 40 A Efficiency .72-.80 (Varies by model) ENVIRONMENTAL SPECIFICATIONS Ambient Operating 0 C to + 50 C Temperature Range Derating: See Power Rating Chart Ambient Storage Temp. Range - 40 C to + 85 C Temperature Coefficient Outputs 1 – 4: 0.02% /C Conducted Emissions EN 55022 Class B Altitude 3,000m ASL – Operating 12192m ASL - Storage GENERAL SPECIFICATIONS Dielectric Strength(7) Reinforced Insulation 4242 VDC, Primary to Secondary, 1 Sec. Basic Insulation 2121 VDC, Primary to Ground, 1 Sec. Operational Insulation 500 VDC, Secondary to Ground, 1 Sec. Power Fail Signal (optional) Logic low with input power failure, 2mS minimum prior to output 1 dropping 1% Mean-Time Between Failures 150,000 Hours min., MIL-HDBK-217F, 25° C, GB Weight 0.80 Lbs. Open Frame 1.65 Lbs. Chassis and Cover NOTES Consult factory for alternate output configurations. Consult factory for positive, negative or floating outputs. Refer to Applications Information for complete output power ratings. All specifications are maximum at 25 C, 65W unless otherwise stated, may vary by model and are subject to change without notice. TUV only: SRW-65-2008

ORDERING INFORMATION

Other output configurations available (consult factory) Please specify the following optional features when ordering: CH - Chassis TS - Terminal Strip CO - Cover PF - Power Fail I/O - Isolated outputs OVP - Overvoltage protection

  • RoHS Compliant
  • Universal 85-264 VAC Input
  • Compact 4.0” x 6.0” x 1.1” Size
  • 2 Year Warranty
  • Fits 1U Applications
  • One to Four Outputs
  • EN 60950-1 ITE Certification
  • Class B Emissions per EN 55022
  • Optional Chassis and Cover INTEGRATED POWER DESIGNS 300 Stewart Road ■ Wilkes-Barre, PA 18706 ■ Phone: (570) 824-4666 ■ Fax: (570) 824-4843 ■ Email: sales@ipdpower.com ■ Web: www.ipdpower.com

                   SRW-65 SERIES MECHANICAL SPECIFICATIONS APPLICATIONS INFORMATION 1. Each output can deliver its rated load but total output power must not exceed 65 watts. 2. Semiconductor case temperatures must not exceed 110°C. 3. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air to develop. 4. This product is intended for use as a professionally installed component within information technology. 5. A minimum load of 20% is required on output one to insure proper regulation of remaining outputs. 6. Peak to peak output ripple and noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. 7. This product was type tested and safety certified using the dielectric strength test voltages listed in Table 5B of UL 60950-1. In consideration of Clause 5.2.2, care must be taken to insure that the voltage applied to a reinforced insulation does not overstress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC equivalent test voltages be used when performing a production-line dielectric strength test of the assembled end product. Please consult factory for further information. 8. This power supply has been safety approved and final tested usinmg a DC dielectric strength. Please consult factory before performing an AC dielectric strength test. 9. Maximum screw penetration into mounting holes is .250 inches. MAXIMUM OUTPUT POWER VS. AMBIENT TEMPERATURE CONNECTOR SPECIFICATIONS TB1/G AC Input .156 friction lock header mates with Molex 09-50-3051 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal. TB2 DC Output .156 friction lock header mates with Molex 09-50-3101 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal. PF Optional power fail signal. G Optional power fail signal return. RECOMMENDED AIR FLOW DIRECTION 1 – Optimum 2 – Good 3 – Fair 0 10 20 30 40 50 60 70 Ambient Temperature (C) Output Power (Watts) INTEGRATED POWER DESIGNS 300 Stewart Road ■ Wilkes-Barre, PA 18706 ■ Phone: (570) 824-4666 ■ Fax: (570) 824-4843 ■ Email: sales@ipdpower.com ■ Web: www.ipdpower.com REV.I 10/7/2022