30.0 AMP SCHOTTKY BARRIER RECTIFIERS
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. TYPE NUMBER Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current
FEATURES
Peak Forward Surge Current, 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Maximum Instantaneous Forward Voltage per Leg at 15A Maximum DC Reverse Current TA=25 C at Rated DC Blocking Voltage TA=125 C * High efficiencty operation and Low power loss * Low stored charge majority carrier conduction * High reliability * High forward surge capability * Circuit figure: Common Cathode * Mounting torque: 5 in-lbs maximum * Lead: Lead solderable per MIL-STD-202, method 208 guranteed * Polarity: As Marked * Terminals: Puretin plated SRP3040CT THRU SRP30200CT VOLTAGE RANGE 40 to 200 Volts CURRENT
30.0 Amperes
Dimensions in inches and (millimeters) +PIN 1 PIN 3 PIN 2 CASE TO-247 30.0 200 0.1 V V A A V mA mA UNITS V40 45 60 100 150 200 SRP SRP SRP SRP SRP SRP 3040CT 3045CT 3060CT 30100CT 30150CT 30200CT See FIG.1 0.70 0.80 0.85 0.95 3.4+0 .2- 28 32 42 70 105 140 40 45 60 100 150 200 Typical Thermal Resistance R JA (Note 1) NOTES: 1. Thermal Resistance Junction to Ambient. Operating Storage Temperature Range TSTG Temperature Range TJ -55 +150 -55 +150 C C C/W .102(2.6) .086(2.2) .642(16.3) .618(15.7) .200(5.1) .173(4.4) .858(21.8) .819(20.8) .091(2.3) .070(1.8) .799(20.3) .756(19.2) .130(3.3) .110(2.8) .055(1.4) .040(1.0) .225(5.70) .204(5.20) .264(6.7) .216(5.5) .030(0.75) .017(0.45)
RATING AND CHARACTERISTIC CURVES (SRP3040CT THRU SRP30200CT) FIG.4-MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PEAK FORWARD SURGE CURRENT,(A) 120 200 160 FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE AVERAGE FORWARD CURRENT,(A) NUMBER OF CYCLES AT 60Hz 1 10 5 50 100 Tj=25 C 8.3ms Single Half Sine Wave JEDEC method 0.1 1.0
100 INSTANTANEOUS FORWARD CURRENT,(A)
FORWARD VOLTAGE,(V) Tj=25 C FIG.2-TYPICAL FORWARD CHARACTERISTICS FIG.3 - TYPICAL REVERSE CHARACTERISTICS 1.0 10REVERSE LEAKAGE CURRENT, (mA) PERCENTAGE RATED PEAK REVERSE VOLTAGE 0 20 40 60 80 100 120 140 .01 Tj=25 C Tj=100 C CASE TEMPERATURE,( C) 0 20 40 60 80 100 120 140 160 180 200 Pulse Width 300us 1% Duty Cycle .001 SRP3040CT-SRP30100CT SRP30150CT-SRP30200CT SRP30 40C T-S RP304 5CT SRP 306 0CT -SR P30 100 CT SRP30150CT-S RP30200CT 100