40 WATTS

FEATURES: CHASSIS/COVER OPEN FRAME SAFETY SPECIFICATIONS Underwriters Laboratories File E137708/E140259 UL 62368-1:2014, 2nd Edition CAN/CSA-C22.2 No. 62368-1-14 AAMI/ANSI ES60601-1:2005/(R) 2012 CAN/CSA-C22.2 No. 60601-1:2014 CB Reports/Certificates (including all National and Group Deviations) IEC 62368-1:2014, 2nd Edition IEC 60601-1:2005/A1:2012 TUV SUD America EN 62368-1:2014, 2nd Edition EN 60601-1:2006/A1:2013 Low Voltage Directive (2014/35/EU of February 2014) RoHS Directive (Recast) (2015/863/EU of March 2015) Electrical Equipment (Safety) Regulations 2016 SI No. 1101 Restriction of the Use of Certain Hazardous Substances in EEE Regulations 2012 SI No. 3032 + 2019 SI No.492 MODEL LISTING MODEL NO. OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 SRP-40A-4001 +3.3V/5A +5V/3A +12V/0.7A -12V/0.7A SRP-40A-4002 +5V/5A +3.3V/3A +12V/0.7A -12V/0.7A SRP-40A-4003 +5V/5A -5V/3A +12V/0.7A -12V/0.7A SRP-40A-4004 +5V/5A -5V/3A +15V/0.7A -15V/0.7A SRP-40A-3001 +5V/5A +12V/2A -12V/0.7A SRP-40A-3002 +5V/5A +15V/2A -15V/0.7A SRP-40A-2001 +5V/5A +24V/1.5A SRP-40A-2002 +5V/5A +12V/3A SRP-40A-2003 +5V/5A -5V/4A SRP-40A-2004 +12V/3A -12V/3A SRP-40A-2005 +15V/2.5A -15V/2A SRP-40A-2006 +30V/1.2A -15V/0.7A SRP-40A-2007 +3.3V/5A +5V/0.7A SRP-40A-2008 +6V/5A +9V/1A SRP-40A-2009 +30V/0.5A -30V/0.5A SRP-40A-1001 3.3V/10A SRP-40A-1002 5V/8A SRP-40A-1003 12V/3.33A SRP-40A-1004 15V/2.67A SRP-40A-1005 24V/1.67A SRP-40A-1006 48V/0.83A SRP-40A-1007 9V/4.45A SRP-40A-1008 12V/3.33A

ORDERING INFORMATION

Consult factory for alternate output configurations. Consult factory for positive, negative or floating Output 2. Specify DC Input when ordering SRP-40A-3003 only. Please specify the following optional features when ordering: CH – Chassis I/O – Isolated Outputs CO – Cover TS – Terminal Strip SRP-40A OUTPUT SPECIFICATIONS Total Output Power at 50°C(1) (See Derating Chart) 40W (33W, 1001) Output Voltage Centering Output 1:  0.25% (All outputs Output 2:  5.0% at 50% load) Output 3:  3.0% Output 4:  3.0% Output Voltage Adjust Range Output 1: 95 - 105% Load Regulation Output 1: 0.5% (10-100% load change) Output 2: 5.0% (30-100% load change) (2003,4002) 7.0% (30-100% load change) Output 3: 0.5% (10-100% load change) Output 4: 0.5% (10-100% load change) Source Regulation Outputs 1 – 4: 0.5% Cross Regulation Output 2: 5.0% (Output 1 Output 3: 0.5% varied 50-100%) Output 4: 0.5% Output Noise Outputs 1 - 4: 1.0% Turn on Overshoot None Transient Response Outputs 1 – 4 Voltage Deviation 5.0% Recovery Time 2 ms Load Change 50% to 100% Output Overvoltage Protection Output 1: 110% to 150% Output Overcurrent Protection Outputs 3 & 4: 110% Min. Output Overpower Protection Outputs 1 & 2: 110% Min. Outputs cycle on/off, auto recovery Hold Up Time 10 ms min., 40 W Output, 120V Input Start Up Time 1 Second INPUT SPECIFICATIONS Protection Class I Source Voltage 85 – 264 Volts AC Frequency Range 47 – 63 Hz Source Current True RMS Peak Inrush 1A at 85V Input 30 A Efficiency 0.66 - 0.80 (Varies by model) ENVIRONMENTAL SPECIFICATIONS Ambient Operating 0 C to + 70 C Temperature Range Derating: See Power Rating Chart Ambient Storage Temp. Range - 40 C to + 85 C Temperature Coefficient Outputs 1 – 4: 0.02% /C Altitude 3,000m ASL – Operating – Medical 60601-1 5,000m ASL – Operating – ITE/AV – 62368-1 12,192m ASL – Non-Operating GENERAL SPECIFICATIONS Means of Protection Primary to Secondary 2MOPP (Means of Patient Protection) Primary to Ground 1MOPP (Means of Patient Protection) Secondary to Ground Operational Insulation(Consult factory for 1MOPP) Dielectric Strength(8, 9) Reinforced Insulation 5656 VDC, Primary to Secondary Basic Insulation 2121 VDC, Primary to Ground Operational Insulation 707 VDC, Secondary to Ground Leakage Current Earth Leakage <300µA NC, <1000µA SFC Touch Current <100µA NC, <500µA SFC Mean-Time Between Failures 100,000 Hours min., MIL-HDBK-217F, 25° C, GB Weight 0.49 Lbs. Open Frame 0.85 Lbs. Chassis and Cover EMC SPECIFICATIONS (IEC 60601-1-2:2014, 4TH ED./IEC 61000-6-2:2005) Electrostatic Discharge EN 61000-4-2 8KV contact / 15KV air discharge A Radiated Electromagnetic Field EN 61000-4-3 80MHz-2.7GHz, 10V/m, 80% AM A Electrical Fast Transients/Bursts EN 61000-4-4 2 KV, 5KHz/100KHz A Surge Immunity EN 61000-4-5 2 KV line to earth / 1 KV line to line A Conducted Immunity EN 61000-4-6 0.15 to 80MHz, 10V, 80% AM A Magnetic Field Immunity EN 61000-4-8 30A/m, 60 Hz. A Voltage Dips EN 61000-4-11 0% UT, 0.5 cycles, 0-315° 100/240V A/A 0% UT, 1 cycles, 0° 100/240V A/A 40% UT, 10/12 cycles, 0° 100/240V B/A 70% UT, 25/30 cycles, 0° 100/240V B/A Voltage Interruptions EN 61000-4-11 0% UT, 300 cycles, 0° 100/240V B/B Radiated Emissions EN 55011/32 Class B Conducted Emissions EN 55011/32 Class B Harmonic Current Emissions EN 61000-3-2 Class A Voltage Fluctuations/Flicker EN 61000-3-3 Compliant All specifications are maximum at 25°C/40W unless otherwise stated, may vary by model and are subject to change without notice.

  • Compact 2.5" x 4.25" x 1.2" Size
  • 2 Year Warranty
  • Universal 85-264V Input
  • One to Four Outputs
  • 0-70°C Operating Temperature
  • IEC 60601-1 3rd ed. Medical Cert.
  • IEC 62368-1 2nd ed. Certification
  • IEC 60601-1-2 4th ed. EMC
  • Class B Emissions per EN55011/32
  • RoHS Compliant
  • Optional Chassis/Cover INTEGRATED POWER DESIGNS 300 Stewart Road ■ Wilkes-Barre, PA 18706 ■ Phone: (570) 824-4666 ■ Fax: (570) 824-4843 ■ Email: sales@ipdpower.com ■ Web: www.ipdpower.com

Output Power (Watts) Ambient Temperature (C) O P E N F R A M E O P T I O N A L C H A S S I S & C O V E R SRP-40A SERIES MECHANICAL SPECIFICATIONS APPLICATIONS INFORMATION 1. Each output can deliver its rated current but Total Output Power must not exceed 40W (33W, 1001). 2. Generally, adequate cooling is provided when semiconductor case temperatures do not exceed 70°C rise and transformer temperature does not exceed 60°C rise at any specified ambient temperature. 3. Sufficient area must be provided around power supply to allow natural movement of air to develop in convection-cooled applications. 4. This product is intended for use as a professionally-installed component within information technology, industrial, and medical equipment and is not intended for stand-alone operation. 5. A minimum load of 10% is required on Output 1 to ensure proper regulation of remaining outputs. 6. This product includes only one fuse in the input circuit. In consideration of Clause 8.11.5 of IEC 60601-1:2005, a second fuse may be required in neutral conductor of the end product. 7. Peak-to-Peak Output Ripple and Noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip (tip-and-barrel method, 20 MHz bandwidth. 8. This product was type-tested and safety-certified using the dielectric strength test voltages listed in Table 6 of IEC 60601-1:2005. In consideration of Clause 8.8.3, care must be taken to insure that the voltage applied to a reinforced insulation does not overstress different types and levels of insulation. Primary and secondary to ground capacitors may need to be disconnected prior to performing a dielectric strength test on the power supply or the end product. It is highly recommended that the DC test voltages listed in DVB.1, Annex DVB of UL 60601-1 1st Edition are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information. 9. This power supply has been safety-approved and final-tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric strength test. 10. Remote-Sense terminals may be used to compensate for cable losses up to 250mV, depending on model. The use of a twisted pair, decoupling capacitors, and an appropriately-rated low-impedance capacitor connected across the load will increase noise immunity. 11. Maximum screw penetration into bottom chassis mounting holes is 0.100 inches. Maximum screw penetration into side chassis mounting holes is 0.250 inches. 12. To comply with emissions specifications, all four mounting hole pads must be electrically connected to a common metal chassis. Chassis/Cover option is recommended. Refer to Operating Instructions for additional information. 13. Common RF shielding precautions may need to be taken to assure emissions compliance. Refer to Operating Instructions for additional information. 14. Maximum Ambient Temperature is reduced to 40°C with optional Chassis and Cover. See chart below. MAXIMUM OUTPUT POWER vs. AMBIENT TEMPERATURE CONNECTOR SPECIFICATIONS P1 AC Input 0.156 friction lock header mates with Tyco 640250-3 or equivalent crimp terminal housing with Tyco 3-640706-1 or equivalent crimp terminal. P3 DC Output (Single) 0.156 friction lock header mates with Tyco 770849-6 or equivalent crimp terminal housing with Tyco 3-640707-1 or equivalent crimp terminal. P3 DC Output (Multiple) 0.156 friction lock header mates with Tyco 770849-8 or equivalent crimp terminal housing with Tyco 3-640707-1 or equivalent crimp terminal. P4,P5 Sense 0.100 friction lock header mates with Molex 22-01-2027 or equivalent crimp terminal housing with Molex 08-50-0114 or equivalent crimp terminal. G Ground 0.187 quick disconnect terminal. INTEGRATED POWER DESIGNS 300 Stewart Road ■ Wilkes-Barre, PA 18706 ■ Phone: (570) 824-4666 ■ Fax: (570) 824-4843 ■ Email: sales@ipdpower.com ■ Web: www.ipdpower.com REV. Z 10/7/2022