SCHOTTKY BARRIER RECTIFIER VOLTAGE RANGE 20 to 100 Volts CURRENT 3.0 Amperes MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. resistive or inductive load. SRL3100 THRU SRL320 MAXIMUM RATINGS (@ T A =25 O C unless otherwise noted) ELECTRICA L CHARACTERISTICS (@T A =25 O C unless otherwise noted) RATINGS Maxim um Recurrent Peak Reverse Voltage Maximum RMS Voltage Maxim um DC Blocking Voltage Maximum Average Forward Rectified Current at Derating Lead Temperature Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typica l Thermal Resistance (Note 1) Typica l Current Squared Time Typic al Junction Capacitance (Note 3) SYM BOL V RRM V DC I FSM C J T STG V RMS UNITS Volts Volts Volt s Amp s3.0 100 41.5 160 Amps A S C/W C Storage Temperature Range R ? JA I O pF Operating Temperature Range T J SRL320 125 -65 to + 150 C SRL330 SRL340 SRL350 SRL360 30 40 50 60 14 21 28 35 42 20 30 40 50 60 SRL380 SRL3100 SRL320 SRL330 SRL340 SRL350 SRL360 SRL380 SRL3100 80 100 80 100 56 70 NOTES : 1. Thermal Resistance : At 9.5mm lead lengths, PCB mounted. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. " ROHS compliant" CHARACTERISTICS Maximum Average Reverse Current at Rated DC Blocking Voltage V F SYMBOL I R A Maximum Instantaneous Forward Voltage at 3.0A DC Volts 0.5 100 A = 25 o C A = 100 o C .45 mA UNIT S .60 .72
FEATURES
- High reliability * Low switching loss * Low forward voltage drop * High current capability * High switching capability * Epoxy: Device has UL flammability classification 94V-O * Case: Molded plastic * Lead: MIL-STD-202E method 208C guaranteed * Mounting: position: Any MECHANICAL DATA I T 250 m Dimensions in inches and (millimeters) DO-15 1.0 (25.4 ) MIN. .230 (5.8 ) .300 (7. 6) 1.0 (25. 4) MIN. .140 (3.6 ) .104 (2. 6) DIA. .035 (0. 88) .027 (0. 68)DIA. 2021-06 REV:A
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) INSTANTANEOUS FORWARD VOLTAGE, (V) )Am( ,TNERRUC ESREVER SUOENATNATSNI LEAD TEMPERATURE, ( O 0.1 0.01 1.0 100 1000 )A( ,TNERRUC DRAWROF EGAREVA CJ )Fp( ,ECNATICAPAC NOITCNUJ , 0.5 1.0 1.5 2.0 2.5 3.0 20 40 60 80 100 120 140150100500 1.0 1.20.6 1.8 RATING AND CHARACTERISTICS CURVES ( SRL320 THRU SRL3100 ) FIG.1 TYPICAL FORWARD CURRENTFIG.1 TYPICAL FORWARD CURRENT DERA TING CURVE DERATING CURVE REVERSE VOLTAGE, (V) )A( ,TNERRUC DRAWROF SUOENATNATSNI 0.1 100 200 400 400.41 . 0 4 1 0 8 0 1 0 0 FIG.4 TYPICAL JUNCTION CAPACITANCE FIG.4 TYPICAL JUNCTION CAPACITANCE NUMBER OF CYCLES AT 60Hz )A( ,TNERRUC EGRUS DRAWROF KAEP 100 120 2 5 10 20 50 100 FIG.5 MAXIMUM NON-REPETITIVE FORWARDFIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT SURGE CURRENT Single Phase Half Wave 60Hz Inductive or Resistiv e Load 0.375" (9.5mm) Lead Length TA = 100 O C TA = 25 O C 8.3mS Single Half Sine-Wave JEDEC Method TJ = 25 O C Pulse width=300 μS 1% Duty Cycle SRL380 ~ SRL3100 SRL320 ~SRL340 SRL350~SRL360 023 RLS 043 RLS L3RS 0013 RLS TJ = 25 O C FIG.3 FIG.3 CHARACTERISTICS CHARACTERISTICS FIG.2 REVERSEFIG.2 REVERSE CHARACTERISTICS CHARACTERISTICS INSTANTANEOUS FORWARDMAXIMUMMAXIMUM MAXIMUMMAXIMUM
Year – code: (Y:Last digit of year & Month – code: (M:0~9,O,N,D)Part No.
PACKAGING OF DIODE AND BRIDGE RECTIFIERS AMMO PACK PACKAGE PACKING CODE REEL ( EA ) COMPONENT SPACE(mm) (mm) (mm) TAPE SPACE BOX SIZE CARTON SIZE(mm) CARTON ( EA ) GROSS WEIGHT (Kg) DO-15 -F 1,500 5.0 52 255*73*100 400*268*225 15,000 8.8 BULK PACK PACKAGE DO-15 EA PER BOX INNER BOX SIZE (mm) CARTON SIZE (mm) EA PER CARTON GROSS WEIGHT(Kg) 500 194*84*21 415*220*255 25,000 12.74 PACKING CODE REEL PACK PACKAGE GROSS WEIGHT(Kg) EA PER REEL COMPONENT SPACE TAPE SPACE (mm) CARTON SIZE (mm) (mm) EA PER CARTON REEL DIA DO-15 4,000 5.0 52 330 355*350*335 16,000 10.05-T PACKING CODE (mm) EA PER BOX 4,000 INNER
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi- lity for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" paramet- ers which may be included on RECTRON data sheets and/ or specifications ca- n and do vary in different applications and actual performance may vary over ti- me. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other rela- ted applications where a failure or malfunction of component or circuitry may di- rectly or indirectly cause injury or threaten a life without expressed written appr- oval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rect- ron Inc and its subsidiaries harmless against all claims, damages and expendit- ures. DISCLAIMER NOTICE