Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical para- meters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays Safety Relay SR4 D/M I 4 pole safety relay with either
2 NO+2 NC or 3 NO+1 NC contacts
I Forcibly guided contacts according to EN 50205 I Rated current 8 A I Very small outlines I RoHS compliant (Directive 2002/95/EC) as per product date code 0407
Applications
Emergency shut-off, machine control, elevator and escalator control, light barrier control F0244-A Approvals VREG.-Nr. 40005334, ZE214024, T968/EL 230.00/03 Technical data of approved types on request Contact data Contact configuration 3 N/O contacts and 1 N/C contact or
2 N/O contacts and 2 N/C contacts
Contact set single contact, forcibly guided type A according to EN 50205 Type of interruption micro disconnection Rated current 8 A Rated voltage / max.switching voltage AC 240/400 VAC Maximum breaking capacity AC 2000 VA Utilization class (AC-15) acc. IEC 60947-5-1 NO contact I e 3A/U e 250 VAC (inrush 30 A) NC contact I e 1 . 5A/U e 250 VAC (inrush 15 A) Contact material AgSnO 2 Minimum contact load 10 mA / 5 V Contact resistance w 100 mOhm / 1 A / 24 VDC w 20 Ohm / 10 mA / 5 VDC Mechanical endurance 10x10 6 cycles Rated frequency of operation with / without load 6 min -1 / 150 min-1 Coil data Rated coil voltage range DC coil 5...110 VDC Coil power DC coil appr. 800 mW Operative range 2 Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 005 5 3.8 0.5 31 +10% 806 006 6 4.5 0.6 45 +10% 800 009 9 6.8 0.9 101 +10% 802 012 12 9.0 1.2 180 +10% 800 015 15 11.3 1.5 281 +10% 801 018 18 13.5 1.8 405 +10% 800 021 21 15.8 2.1 551 +10% 800 024 24 18.0 2.4 720 +10% 800 036 36 27.0 3.6 1620 +10% 800 040 40 30.0 4.0 2000 +10% 800 048 48 36.0 4.8 2880 +10% 800 060 60 45.0 6.0 4500 +10% 800 085 85 63.8 8.5 9031 +10% 800 110 110 82.5 11.0 15125 +10% 800 All figures are given for coil without preenergization, at ambient temperature +23°C
Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical para- meters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays Safety Relay SR4 D/M (Continued) Product key SR4 4 Type Contact configuration D 2 NO + 2 NC contacts M 3 NO + 1 NC contacts Contact material
4 AgSnO2
Coil code = rated coil voltage (e.g. 024=24 VDC) Other types on request PCB layout / terminal assignment Bottom view on solder pins Dimensions
2 NO and 2 NC contacts
3 NO and 1 NC contacts
Other coil voltages on request Insulation Insulation resistance coil-contact circuit > 100x10 6 Ohm Dielectric strength coil-contact circuit 4000 V rms open contact circuit 1500 V rms adjacent contact circuits 2500 V rms Clearance / creepage coil-contact circuit W 10 / 10 mm adjacent contact circuits W 3 / 3.5 mm adjacent contact circuits (UL840) W 1.3 / 3.5 mm Material group of insulation parts W IIIa Tracking index of relay base CTI 250 Insulation to IEC 60664-1 Type of insulation coil-contact circuit reinforced open contact circuit functional adjacent contact circuits basic Rated insulation voltage 250 V Pollution degree 2 Rated voltage system 230/400 V Overvoltage category III Insulation to EN 50178 Type of insulation coil-contact circuit reinforced adjacent contact circuits basic Other data RoHS - Directive 2002/95/EC compliant as per product date code 0407 Ambient temperature range -25...+70°C Vibration resistance (function) NO / NC contact > 10 / 2 g, 10....200 Hz Shock resistance (function) NO / NC contact > 10 / 2 g, 11 ms half sine Category of protection RT III 1) Resistance to soldering heat 260°C / 5 s Relay weight 16 g Packaging unit 10 pcs 1) please contact technical support for washing parameters
Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical para- meters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays Safety Relay SR4 D/M (Continued) Product key Type Contact configuration Contact material Coil Part number SR4D4005 4 pole 2 NO + 2 NC AgSnO 2 5 VDC 7-1415054-1 SR4D4006 safety relay contacts 6 VDC 8-1415054-1 SR4D4009 9 VDC 9-1415054-1 SR4D4012 12 VDC 0-1415055-1 SR4D4018 18 VDC 1-1415055-1 SR4D4021 21 VDC 2-1415055-1 SR4D4024 24 VDC 3-1415055-1 SR4D4036 36 VDC 4-1415055-1 SR4D4040 40 VDC 5-1415055-1 SR4D4048 48 VDC 6-1415055-1 SR4D4060 60 VDC 7-1415055-1 SR4D4085 85 VDC 8-1415055-1 SR4D4110 110 VDC 9-1415055-1 SR4M4005 3 NO + 1 NC 5 VDC 5-1415053-1 SR4M4006 contacts 6 VDC 6-1415053-1 SR4M4009 9 VDC 7-1415053-1 SR4M4012 12 VDC 8-1415053-1 SR4M4018 18 VDC 9-1415053-1 SR4M4021 21 VDC 0-1415054-1 SR4M4024 24 VDC 4-1415053-1 SR4M4036 36 VDC 1-1415054-1 SR4M4040 40 VDC 2-1415054-1 SR4M4048 48 VDC 3-1415054-1 SR4M4060 60 VDC 4-1415054-1 SR4M4085 85 VDC 5-1415054-1 SR4M4110 110 VDC 6-1415054-1