Technical content

Sym. Parameter Test Conditions Min. Typ. Max. Unit Vin Input Voltage Operating Voltage 90 264 VAC Fin Input Frequency 47 63 Hz Wo Output Power Range Vin=90 to 264VAC 0 60 W Vo Output Voltage Range See rating chart V Io Output Current Range See rating chart A Iil Input Current (Low Line) Io=Full load, Vin=115VAC 1.6 A Iih Input Current (High Line) Io=Full load, Vin=230VAC 1.0 A Irl Low Line Inrush Current Io=Full load, 25°c, Cool start, Vin=115VAC 12 15 A Irh High Line Inrush Current Io=Full load, 25°c, Cool start, Vin=230VAC 26 30 A Eff Efficiency Io=Full Load, Vin=230VAC 70 83 88 % REG-i Line Regulation Io=Full Load 0.5 1 % REG-o Load Regulation Vin=230VAC 3 7 % OVP Over Voltage Protection 112 132 % OCP Over Current Protection 110 150 % Ttr Transient Response Io=Full Load to Half Load, Vin=100VAC 4 mS Thold Hold-Up Time Io=Full Load, Vin=110VAC 16 mS Ts Start Up Time Io=Full Load, Vin=100VAC 0.3 1 2 S Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC 1 2 % Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC 0.5 0.75 mA Tc Temperature Coefficient All output -0.04 0.04 %/°c SPU60 SERIES 60W Desk Top Switching Power Supplies For I.T.E. (Small Size) Wide Input Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C14 Input Inlet Single output Output Voltage Available From 3 VDC Thru 50 VDC Optional Output Connector (See appendix) Input Surge Current, Over Voltage and Over Load protection Splash proof Class I Insulation Two Years Warranty Safety Approvals : Electrical Characteristics: CB Description: Features: CC USUS S&E Environmental : Hr Relative Humidity 5 95 % Toper Operating Temperature Tstg Storage Temperature Pd 0 70 85 -40 Sym. Parameter Min. Typ. Max. Unit Derate linearly from 100% load at 40 C to 50% load at 70 C Te st Conditions C C The SPU60 series of AC/DC switching mode power supplies provide 60 Watts of continuous output power. All supplies are UL 94V-1 min compliant, include IEC-320-C14 input for worldwide applications. All models meet FCC Part-15 class B and CISPR-22 class B emission Limits and are designed to comply with UL/c-UL(UL 1950), ITS/GS(EN 60950) and new CE requirements. All units are 100% burned in and tested.

Model Number Output Voltage Output Current Total Regulation Maximum Output Power SPU60-101 03 ~ 05 VDC 6.60 ~ 4.00 A 7% 20W SPU60-102 05 ~ 06 VDC 6.00 ~ 5.00 A 5% 30W SPU60-103 06 ~ 08 VDC 5.83 ~ 4.37 A 5% 35W SPU60-104 08 ~ 11 VDC 5.00 ~ 3.63 A 5% 40W SPU60-105 11 ~ 13 VDC 4.54 ~ 3.84 A 5% 50W SPU60-105-1 11 ~ 13 VDC 5.45 ~ 4.61 A 5% 60W SPU60-106 13 ~ 16 VDC 4.23 ~ 3.43 A 5% 55W SPU60-107 16 ~ 21 VDC 3.75 ~ 2.85 A 5% 60W SPU60-108 21 ~ 27 VDC 2.85 ~ 2.22 A 5% 60W SPU60-109 27 ~ 33 VDC 2.22 ~ 1.81 A 5% 60W SPU60-110 33 ~ 40 VDC 1.81 ~ 1.50 A 3% 60W SPU60-111 40 ~ 50 VDC 1.50 ~ 1.20 A 3% 60W SPU60 SERIES Mechanical Specifications : Note: 1. Dimensions are shown in mm. 2. Weight: 340gs approx. 3. Optional output connector: See page Appendix. Safety Specifications: Output Voltage And Current Rating Chart ( Single Output ) : Parameter Te st Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 4242 VDC Primary to ground 2121 Test Voltage=500VDC 50 M Vin=220VAC B CLASS Sym. Vps Vpg Ri CISPR FCC Isolation Resistance EMI requirements for CISPR-22 Vin=110VAC VDC B CLASS Dielectric Withstanding Voltage for Primary to Ground EMI requirements for FCC PART-15 60W Desk Top Switching Power Supplies For I.T.E. (Small Size) MODEL SPU60-105-1 have only approved UL/c-UL,ITS/GS,CE