SPU40 MPSIND | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
40W Desk Top Switching Power Supplies For I.T.E. Wide Input Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C14 Input Inlet Single output Optional Output Connector (See appendix) Over Voltage Protection (Crowbar Design) Splash proof Class I CEC and Energy Star compliance Approved as Limited Power Source (LPS). 2 year warranty Safety Approvals : Electrical Characteristics: Description: Features: Environmental : Hr Relative Humidity Operating Temperature at 25 C, Calculated per MIL-HDBK-217F 0.1M Hrs Toper Operating Temperature Tstg MTBF Storage Temperature Pd 0 70 85 -40 Sym. Parameter Min. Typ. Max. Unit Derate linearly from 100% load at 40 C to 50% load at 70 C Test Conditions C C The SPU40 series of AC/DC switching mode power supplies provide 40 Watts of continuous output power and is well- suited for a variety of applications. All supplies are UL 94V-1 min compliant. All models meet FCC Part-15 class B and CISPR-22 class B emission Limits and are designed to comply with UL/c-UL(UL 60950-1), TUV/GS(EN 60950-1) and new CE requirements. All units are 100% burned in and tested. CB S E P Sym. Parameter Test Conditions Min. Typ. Max. Unit Vin Input Voltage Operating Voltage 90 264 VAC fin Input Frequency 47 63 Hz Po Output Power Range Vin=90 to 264VAC 0 40 W Vo Output Voltage Range See rating chart V Io Output Current Range See rating chart A Iil Input Current (Low Line) Io=Full load, Vin=115VAC 1 A Iih Input Current (High Line) Io=Full load, Vin=230VAC 0.5 A Irl Low Line Inrush Current Io=Full load, 25c, Cool start, Vin=115VAC 20 25 A Irh High Line Inrush Current Io=Full load, 25c, Cool start, Vin=230VAC 42 50 A Eff Efficiency Io=Full Load, Vin=230VAC 78 83 90 % REG-i Line Regulation Io=Full Load 0.5 1 % REG-o Load Regulation Vin=230VAC 3 7 % OVP Over Voltage Protection 112 132 % OCP Over Current Protection 110 150 % Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC 4 mS Thold Hold-Up Time Io=Full Load, Vin=110VAC 12 mS Ts Start Up Time Io=Full Load, Vin=100VAC 0.3 0.5 S Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC 0.5 1 % Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC 0.5 0.75 mA TC Temperature Coefficient All output -0.04 0.04 %/c Pno No-Load Power Consumption No load, Vin=240VAC 0.3 0.5 W Agree to apply for the PSE if order on hand
Note: 1. Dimensions are shown in mm. 2. Weight: 275gs approx. 3. Optional output connector: See page Appendix. Safety Specifications: Output Voltage And Current Rating Chart ( Single Output ) : Parameter Test Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 4242 VDC Primary to ground 2121 Test Voltage=500VDC 50 M Vin=220VAC B CLASS Sym. Vps Vpg Ris CISPR FCC Isolation Resistance EMI requirements for CISPR-22 Vin=110VAC VDC B CLASS Dielectric Withstanding Voltage for Primary to Ground EMI requirements for FCC PART-15 40W Desk Top Switching Power Supplies For I.T.E. Mechanical Specifications : Model. 102~105 shall use “AWG#16,4FT long “ to meet the requirement of CEC. Model. 106~111 shall use “AWG#18,4FT long “ to meet the requirement of CEC. The regulation will be changed by modified output cable. Model Number Output Voltage Output Current Total Regulation Maximum Output Power SPU40-102 5 ~ 06 VDC 5.00 ~ 4.16 A 5% 25W SPU40-103 6 ~ 08 VDC 5.00 ~ 3.75 A 5% 30W SPU40-104 8 ~ 11 VDC 4.37 ~ 3.18 A 4% 35W SPU40-105 11 ~ 13 VDC 3.63 ~ 3.07 A 3% 40W SPU40-106 13 ~ 16 VDC 3.07 ~ 2.50 A 3% 40W SPU40-107 16 ~ 21 VDC 2.50 ~ 1.90 A 3% 40W SPU40-108 21 ~ 27 VDC 1.90 ~ 1.48 A 2% 40W SPU40-109 27 ~ 33 VDC 1.48 ~ 1.21 A 2% 40W SPU40-110 33 ~ 40 VDC 1.21 ~ 1.00 A 2% 40W SPU40-111 40 ~ 50 VDC 1.00 ~ 0.80 A 2% 40W Mark " " means " PSE approval "* The model had been approved by CEC level IV number of 102~104 . The model had been approved by CEC level V number of 105~111 .