SPU26 MPSIND | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Description: Safety Approvals: Electrical Characteristics: Features: The SPU26 series of AC/DC switching mode power supplies provide 25 Watts of continuous output power. All supplies are UL 94V-1 min compliant. All models meet FCC Part-15 class B and CISPR-22 class B emission Limits and are nddesigned to comply with UL/c-UL(UL 60950-1:2 Edition), ndTUV/GS(EN 60950-1:2 Edition) and new CE requirements. All units are 100% burned in and tested. Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz Interchangeable Plug Optional Output Connector (See appendix) Single Output Energy Star 2.0, Efficiency level V Class II 2 year warranty 25W Interchangeable Wall Mount Switching Power Supplies For I.T.E. S E P CB Environmental : Toper Operating Temperature Tstg Storage Temperature 0 70 -40 Sym. Parameter Min. Typ. Max. UnitTest Conditions C C Hr Ho Storage Humidity 75 % %Operating Humidity Pd 95 0 Derate linearly from 100% load at 40 C to 50% load at 70 C Hrs MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F 0.1M Agree to apply for the PSE if order on hand Sym. Parameter Test Conditions Min. Typ. Max. Unit Vin Safety Approvals Input Voltage Range 100 240 VAC Operate Voltage Range 90 264 VAC fin Input Frequency 47 63 Hz Po Output Power Range Vin=90 to 264VAC 25 W Vo Output Voltage Range See rating chart V Io Output Current Range See rating chart A Iil Input Current (Low Line) Io=Full load, Vin=115VAC 0.55 A Iih Input Current (High Line) Io=Full load, Vin=230VAC 0.35 A Irl Low Line Inrush Current Io=Full load, 25c, Cool start, Vin=115VAC 25 50 A Irh High Line Inrush Current Io=Full load, 25c, Cool start, Vin=230VAC 50 100 A Eff Efficiency Io=Full Load, Vin=230VAC 77 82 85 % REG-i Line Regulation Io=Full Load 0.5 1 % REG-o Load Regulation Vin=230VAC 3 5 % OVP Over Voltage Protection Nil % OCP Over Current Protection Nil.But,Output protected to short circut conditions % Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC 4 mS Thold Hold-Up Time Io=Full Load, Vin=110VAC 12 mS Ts Start Up Time Io=Full Load, Vin=100VAC 2 3 S Vp-p Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC 0.5 1 % Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC 0.25 mA TC Temperature Coefficient All output -0.04 0.04 %/c Pno No-Load Power Consumption No load, Vin=240VAC 0 0.25 0.3 W
Safety Specifications: Mechanical Specifications : Note: 1. Dimensions are shown in mm. 2. Weight: 200gs approx. 3. Optional output connector: See page Appendix. Output Voltage And Current Rating Chart ( Single Output ) : Parameter Test Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 4242 VDC Sym. Vps Test Voltage=500VDC 50 M Vin=220VAC B CLASS Ris CISPR FCC Isolation Resistance EMI requirements for CISPR-22 Vin=110VAC B CLASSEMI requirements for FCC PART-15 SPU26-102~109 are required to use AWG#18×2C/4FT output cable. SPU26-110~111 are required to use AWG#20×2C/4FT output cable. The regulation and efficiency will be changed by modified output cable. 25W Interchangeable Wall Mount Switching Power Supplies For I.T.E. Model Number Output Voltage Max. Output Current Total Regulation Max. Output Watts SPU26-102 5 ~ 6 VDC 3.30 ~ 2.75 A 5% 16.5W SPU26-103 6 ~ 8 VDC 3.33 ~ 2.50 A 5% 20W SPU26-104 8 ~ 11 VDC 2.75 ~ 2.00 A 5% 22W SPU26-105 11 ~ 13 VDC 2.27 ~ 1.92 A 5% 25W SPU26-106 13 ~ 16 VDC 1.92 ~ 1.56 A 5% 25W SPU26-107 16 ~ 21 VDC 1.56 ~ 1.19 A 5% 25W SPU26-108 21 ~ 27 VDC 1.19 ~ 0.92 A 3% 25W SPU26-109 27 ~ 33 VDC 0.92 ~ 0.75 A 3% 25W SPU26-110 33 ~ 40 VDC 0.75 ~ 0.62 A 3% 25W SPU26-111 40 ~ 48 VDC 0.62 ~ 0.53 A 3% 25W