The Slimline Power System provides advanced controller features in a compact, cost-efficient footprint. The SPS shelf is 1.75” high, 10.3” deep and mounts in 19-inch or 23-inch wide frames, with three power slots for rectifiers and distribution. The Pulsar Edge controller has Ethernet connectivity to facilitate remote network management to monitor and control rectifiers, batteries, and distribution. SPS is a reliable DC power solution where system height and depth are restricted. Shelf Options The Slimline Power System product line provides several shelf options equipped with Ethernet, alarm inputs/outputs, and 1-Wire™ connection for battery voltage and temperature monitoring. The rectifier-only shelf holds up to three 1000 Watt rectifier modules. Shelves can be deployed in parallel to increase output capacity. Other shelf configurations hold up to two 1000 Watt rectifier modules and include an integrated distribution module with circuit breakers, GMT fuse positions, and low-voltage battery disconnect circuit. SPS TE Rectifier This hardened rectifier is a single phase, hot pluggable, fan cooled rectifier that provides up to 1000 Watts of high availability DC power. The constant output power characteristics, extended temperature range, universal AC input, and compact size are key attributes that make this rectifier the right choice for your power needs. Pulsar Edge Controller SPS features the Pulsar Edge controller delivering large system intelligence in a small system form factor. Ethernet connectivity with SNMP facilitates remote network management. Benefits Reliability – Simplified deployment – Proven field performance – Hardened for extreme environments Intelligence – Industry leading controller features – Ethernet interface for remote access – Centralized network management Investment Protection – Engineered to reduce installation time – Versatile configurations – Efficient operation On Time Delivery – Standard building blocks – 4 - 6 week availability – 24/7 technical support

  • Customer premise power for converged networks
  • Large plant features in a small plant package
  • 3000 Watts / 60 Amps single shelf capacity in 1RU
  • 10.3 inches (264mm) depth is ideal where space is restricted
  • 95% Efficiency Slimline Power System 48V DC Outside Plant and Customer Premise Solution Total Efficiency The GE Total Efficiency™ (TE) architecture reduces energy loss and lowers cooling costs by 50-70%. TE products will prioritize sustainable energy sources like solar, wind, water and fuel cells over traditional utility grid or diesel generator sources – and they will intelligently respond to smart grid information to reduce consumption during peak demand periods. Active Rectifier Management (ARM) and Battery Charging Optimization (BCO) features increase efficiency on current and legacy power infrastructures. The Total Efficiency architecture addresses issues end- to-end based on our proven experience and expertise in batteries, power distribution, DC energy systems, AC-DC power supplies, and DC-DC board mounted power to deliver a solution that is more safe, reliable and energy efficient than competitive alternatives. Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13

Applications

The SPS TE rectifiers are single phase, hot-pluggable, fan cooled rectifiers that provide highly reliable DC power. As cost-effective rectifiers that occupy just 1RU, its shallow depth is an ideal power solution for space critical applications. The constant output power characteristics as well as the extended temperature range, universal AC input voltage range and compact size are key attributes that make this rectifier the right choice for your power needs. These rectifiers are applicable for indoor and outdoor environments especially where equipment depth and height are restricted. The SPS TE rectifiers communicate digitally to the Pulsar Edge controller family over a RS485 bus to add extensive monitoring and alarm management facilities. Its flexible and sophisticated feature set makes this front-end supply an excellent choice for power in a variety of application spaces.

  • Telecommunications networks
  • Digital subscriber line (DSL)
  • Indoor/outdoor wireless
  • Routers/switches
  • Fiber in the loop
  • Transmission
  • Data networks
  • PBX
  • Extended temperature range
  • Redundant fan cooling
  • Front panel LED indicators
  • 1U height, minimized depth
  • Universal AC input
  • Analog load sharing
  • Hot pluggable
  • RoHS compliant Input EP0500UTEZ EP1000UTEZ EP1600UTEZ Voltage Range - Low-Line - High-Line 90-175Vac (500W) 176-264Vac (500W) 90-175Vac (1000W) 176-264Vac (1000W) 90-175Vac (1200W) 176-264Vac (1600W) Input Current 6.25-4.5A @ 90-120Vac 2.55A @ 230Vac 12.5-9.3A @ 90-120Vac 5.1A @ 230Vac 15-12A @ 90-120Vac 7.5A @ 230Vac Input Frequency 45 – 65Hz 45 – 65Hz 45 – 65Hz Inrush Transient 25 Apk 25 Apk 25 Apk Power Factor ~1.0 ~1.0 ~1.0 Efficiency 95% 95% 95% Total Harmonic Distortion <5% <5% <5% Holdup Time >10 ms full power >10 ms full power >10 ms full power Output Voltage Adjust Range 42-58Vdc 42-58Vdc 42-58Vdc Voltage Nominal 52.0V 52.0V 52.0V Rated Output Current - Low Line - High Line 10Adc max 10Adc max 20Adc max 20Adc max 24Adc max 32Adc max Rated Output Power - Low Line - High Line

500 Watts

1000 Watts

1200 Watts

1600 Watts

Psophometric Noise <5 mV max <5 mV max <5 mV max Ripple <200 mVpkpk <200 mVpkpk <200 mVpkpk Overvoltage Protection 59.5Vdc 59.5Vdc 59.5Vdc Control and Monitoring Visual Status Indicators Run, Alarm and Fault LEDs Serial Interface Half duplex RS485 (GP Protocol) Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 TEChnICAl SPECIFICATIOnS - RECTIFIERS

Operating Temperature -40°C to +75°C (-40°F to 167°F) Storage Temperature -40°C to +85°C (-40°F to 185°F) Power Derating > +50°C 2% per degree Celcius Humidity < 95% non-condensing Altitude 4000M max Audible Noise < 55dBA Safety and Standards Compliance NEBs Evaluated by independent NRTL test lab to Telcordia GR63 & GR 1089, Issue 4 Safety CE mark to Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/E UL 60950-1, Recognized CSA C22.2 No. 60950-1-03 Certified VDE0805:2001 12 (EN 609501) Licensed RoHS Compliant to RoHS EU Directive 2002/95/EC EMC CISPR22 (EN55022) Class B and FCC-CFR, Part 15, sub-part B Class B with shelf; GR1089 Class A ESD EN61000-4-2, Level 4 Mechanical Length (inch/mm) 8.11 / 206.0 Width (inch/mm) 4.98 / 126.5 Height (inch/mm) 1.64 / 41.6 Weight (lb/Kg) 3.08 / 1.4 Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 Outline Drawing TEChnICAl SPECIFICATIOnS - RECTIFIERS

The SPS Pulsar Edge controller delivers large system intelligence in a small system form factor. This family of controllers functions as network interface cards (NIC) and as a full-featured battery plant controller. Its thin modular plug-in form factor minimizes shelf space consumption allowing maximum power module and distribution capabilities. The controller is utilized in bulk power applications in data centers and enterprise applications. Ethernet connectivity with SNMP facilitates remote network management. Access through its front-accessible RS232 or USB port and aided by the EasyView2 graphical enables full user interface locally. Optional 1U display version allows convenient access to all controller functions without requiring external cable connections. The display also features alarm context sensitive backlighting for at-a-glance system status. As a battery plant controller, it provides a complete set of features to monitor and control rectifiers, batteries, and distribution. A flexible set of configurable inputs allow the Pulsar Edge controller to monitor a wide variety of system equipment and incorporate appropriate state information enabling a centralized point of management. The controller utilizes standard network management protocols allowing for advanced network supervision. GE Galaxy Manager™ software is the centralized visibility and control component of a comprehensive power management system designed to meet engineering, operations and maintenance needs. The Galaxy Manager client-server architecture enables remote access to system controllers across the power network.

  • Telecommunications networks
  • Digital subscriber line (DSL)
  • Indoor/outdoor wireless
  • Routers/switches
  • Fiber in the loop
  • Transmission
  • Data networks
  • PBX Remote Access and Features
  • Integrated 10/100Base-T Ethernet Network - TCP/IP - SNMP V2c for management - SMTP for email - Telnet for command line interface - DHCP for plug-n-play - FTP for rapid backup and upgrades - HTTP for standard web pages and browsers - Compatible with Galaxy Manager and other management packages - Shielded RJ-45 interface referenced to chassis ground
  • Password protected security levels: User, Super-User, Administrator for all access
  • Ground-referenced RS232 system port
  • ANSI T1.317 command-line interface
  • Modem access support - Remote via external modem - Callback security
  • EasyView2, Windows-based GUI software for local terminal or Modem access
  • Optional 1U display with alarm indicating backlight feature Standard System Features
  • Monitor and control of more than 40 connected devices - Maximum of 32 rectifiers - Maximum of 6 distribution control cards - Robust RS485 system bus
  • Standard and user defined alarms - Alarm test - Assignable alarm severity: Critical, Major, Minor, Warning, and record-only
  • Rectifier management features - Automatic rectifier restart - Adaptive Rectifier Management (energy efficiency) - Remote rectifier (on/off) - Reserve Operation - Automatic rectifier sequence control - N + X redundancy check
  • Multiple Low Voltage Load and Low Voltage Battery Disconnect thresholds (4)
  • Configuration, statistics, and history - All stored in non-volatile memory - Remote/local backup and restore of configuration data
  • Industry standard defaults - Customer specific configurations available
  • Remote/ local software upgrade
  • Basic, busy hour, and trend statistics
  • Detailed event history
  • User defined events and derived channels Standard Battery Management Features
  • Float/boost mode control - Manual boost - Manual timed boost locally, T1.317, and remotely initiated - Auto boost terminated by time or current
  • Battery discharge testing - Manual (local/remote) - Periodic - Plant Battery Test (PBT) input driven - Configurable threshold or 20% algorithm - Graphical discharge data - Rectifiers on-line during test
  • Slope thermal compensation - High temperature - Low temperature - Step temperature - STC Enable/Disable, low temperature Enable/Disable - Configurable mV/°C slopes
  • State of charge indication
  • High temperature disconnect setting
  • Reserve-time prediction
  • Recharge current limit
  • Emergency Power-Off input Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 TEChnICAl SPECIFICATIOnS - COnTROllER

Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 Integrated Monitoring Inputs/Outputs

  • System plant voltage (accuracy ±0.5%, resolution 0.01V)
  • One system shunt (accuracy ±1% full scale, resolution 1A) - Battery or load - Mounted in the return side of DC bus
  • Up to 15 binary inputs - Six inputs close/open to battery - 9 input close/open to return (number is dependent upon number of output alarms) - User assignable
  • Up to 5 user assignable Form-C output alarms (50VDC @.3A)
  • 1-Wire™ bus devices - Up to 16 temperature probes (QS873) - Up to 6 mid-string monitors (ES771) Galaxy Manager Compatible
  • Centralized web server and database with multiple user access to live or managed data with drill down to problem details
  • Monitor and control of more than 40 connected devices
  • Management information from polling or alarms received from alarm traps from multiple sites are available on one screen via the inter/ intranet
  • Trend user selected data over time
  • Automatic or manual report generation
  • Standard engineering tools like reserve time calculators and cable voltage drop analyzer General Operating Voltage ±24 Vdc, ±48 Vdc (Range: ±18 to ±60 Vdc) Input Power Less than 7W Operating Temperature Range -40°C to +70°C (-40°F to 167°F) Operating Relative Humidity 0 - 95% (non-condensing) Storage Temperature Range -40°C to +85°C (-40°F to 185°F) Display 8-line by 40-character backlit LCD EMC FCC/EN55022 Class A, CISPR22 Level A Agency Certifications Electrostatic Discharge EN 61000-4-2 level 4 Radiated Emissions FCC, Class A; EN 55022, Class A Safety UL Listed Component as Part of CPL or SPS Power System TEChnICAl SPECIFICATIOnS - COnTROllER

48V DC Outside Plant and Customer Premise Solution

Features

The Slimline Power System power shelf provides advanced controller features in a compact, cost-efficient footprint. The SPS shelf is 1.75” high, 10.3” deep and mounts in 19-inch or 23-inch wide frames, with three power slots for rectifiers and distribution. The Pulsar Edge controller has Ethernet connectivity to facilitate remote network management to monitor and control rectifiers, batteries, and distribution. SPS is a reliable DC power solution where system height and depth are restricted. The SPS product line provides several shelf options equipped with Ethernet, alarm inputs/outputs, and 1-Wire™ connection for battery voltage and temperature monitoring. The rectifier-only shelf holds up to three 1000 Watt rectifier modules. Shelves can be deployed in parallel to increase output capacity. Other shelf configurations hold up to two

1000 Watt rectifier modules and include an integrated distribution

module with circuit breakers, GMT fuse positions, and low-voltage battery disconnect circuit.

  • SPS rectifiers produce 42Vdc to 58Vdc output; up to 1000W high line
  • Universal AC input: 90-290VAC
  • AC input options: IEC-320 C13 or C19 style cords per rectifier or per shelf
  • DC output bus is rated for 60A with two-hole lug landings for

2 AWG wire

  • Temperature hardened harsh environments. (-40°C to +75°C)
  • Compact size: 1U (1.75”) high, 10.3” deep
  • Adjustable mounting ears for either flush front or 5- inch set back position
  • Two rectifier only shelves may be connected together for larger power requirements
  • Plug-N-Play SPS841A controller with Web based interface available with or without display. Non display version has DB9 craft port and remote LAN access. Display version has USB craft port and remote LAN access.
  • Distribution options include one or two 30A battery breakers, up to 10 GMT load fuses and Low Voltage Battery Disconnect (LVBD) Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 ORDERInG InFORMATIOn – SlIMlInE P OwER Sy STEM Ordering Information – Slimline Power System

Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 Shelf Options Rear View list 1 Rear View list 1 A DC DC AC ACACAC 1-Wire LAN 1-Wire LAN Control/Alarms Control/Alarms list 1 and 1A Power Shelf

  • DC output buses are M6 studs on 5/8” centers for up to 2gage cable pair, plastic cover provides touch proof protection
  • AC input is single IEC-320 C19 style cord for List 1 or three C13 style cords for List 1A
  • 1-Wire port for battery voltage and temperature monitoring, LAN port and alarm output connector
  • Connector for LVD, shunt and fuse alarm monitoring of external distribution panel ORDERInG InFORMATIOn – SlIMlInE P OwER Sy STEM Shelf line Drawing - J2007003

Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 Shelf Options - continued Front View list 2D and 2AD Front View list 4 and 4A Rear View list 2D Rear View list 2AD Rear View list 4 Rear View list 4A Controller Slot Controller Slot Slot 2 Slot 2 Slot 1 Slot 1 AC AC AC AC Breaker Breakers GMTs GMTs 1-Wire LAN 1-Wire LAN 1-Wire LAN 1-Wire LAN Terminal Blocks Control/Alarms Control/Alarms Control/Alarms Control/Alarms list 2D and 2AD Power Shelf with Distribution

  • Full front access for battery and load connections
  • 30A battery breaker with terminal block input for 8 gage wire, LVBD
  • 6 GMT fuses with terminal block output for 12 gage wire, 15A max fuse size
  • AC input is single IEC-320 C13 style cord for List 2D or two C13 style cords for List 2AD
  • 1-Wire port for battery voltage and temperature monitoring, LAN port and alarm input and output connectors
  • List 2D and 2AD Power Shelves also available without LVBD list 4 and 4A Power Shelf with Distribution
  • Full rear access to all connections
  • Two 30A battery breakers with terminal block inputs for 8 gage wire, LVBD
  • 10 GMT fuses with terminal block output for 12 gage wire, 15A max fuse size
  • AC input is single IEC-320 C13 style cord for List 4 or two C13 style cords for List 4A
  • 1-Wire port for battery voltage and temperature monitoring, LAN port, alarm input and output connectors
  • List 4 and 4A Power Shelves also available without LVBD ORDERInG InFORMATIOn – SlIMlInE P OwER Sy STEM Temperature Measurement Temperature/Voltage Measurement Temperature/Voltage probes are needed for battery monitoring. They are connected to each battery or battery string to provide slope thermal compensation, temperature alarms and voltage imbalance alarms. Battery Monitoring +-+ USE COUPLER 555052-1 AND G-STYLE CABLE TO DAISY CHAIN B-STYLE CABLE UP TO 150 FEET TO CONTROLLER - -+ + - 48V battery string #1 +-+- -+ + - 48V battery string #2 +-+- -+ + - 48V battery string #3 C CCB TRIM BROWN VOLTAGE SENSE WIRE ON B AND C-STYLE CABLES MAX 16 PROBES +-+ To Controller To Next ES771 - -+ + - 48V battery string #1 +-+- -+ + - 48V battery string #2 +-+- -+ + - 48V battery string #3 ES771 Voltage Module 108958422 CC G G D USE COUPLER 555052-1 TO DAISY CHAIN G-STYLE CABLES UP TO 150 FEET VOLTAGE SENSE WIRE

Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 Communication Signals

  • J1 provides alarm outputs and inputs based on the controller installed (see table below). Inputs are “Dry”, no voltage, contact Closures or Opens to a common return on pin 6. Outputs are relay contacts. Both input and output alarms are customer defined on the controller’s web pages.
  • J2 provides alarm inputs (see table below). Alarm inputs are contact Closures or Opens to the non-grounded side of the dc bus [-48V]. Pins 6, 7, 8 provide -48V for these alarm inputs.
  • J3 battery thermal probe (QS873A) or battery mid-string voltage monitor (ES771) with battery thermal probe.
  • J4 shelf to shelf communication connection (List1, 1A)
  • J5 LAN/Ethernet.
  • J7 provides distribution control for shelves with external distribution (List 1, 1A). See table below. All Shelves List 1 and 1A Shelves J1 AlARM COnnECTOR Pin Signals for SPS841A_3C3R Signals for SPS841A_0I5R

1 ALM1 Input Alarm Relay 3 Rtn

2 ALM2 Input Alarm Relay 2 Rtn

3 Alarm Relay 1 Rtn Alarm Relay 1 Rtn

4 Power Minor Rtn Power Minor Rtn

5 Power Major Rtn Power Major Rtn

6 ALM1, 2, 6C RTNS Alarm Relay 3

7 ALM6 Input Alarm Relay 2

8 Alarm Relay 1 Alarm Relay 1

9 Power Minor Power Minor

10 Power Major Power Major

1 FAJ

2 Coil Rtn

3 LVD_NC

4 LVD_NO

5 Shunt-

7 Coil1

8 Coil2

9 LVD Status Rtn

10 Shunt+

1 ALM6 Input

2 —

3 ALM3 Input

4 ALM4 Input

5 ALM5 Input

  • SPS841A plugs into shelf. USB craft port (display) or DB9 craft port (non-display) is on the front of the unit. Alarm inputs and outputs, and Ethernet connection are located on the back of the shelf.
  • Web based interface for local (Craft Port) and remote (LAN) access
  • Ethernet Interface – TCP/IP, FTP, Telnet, HTTP, SMTP support
  • Alarm inputs and outputs are configurable with options for either 3 output alarm relays (SPS841A_3C3R controller) or 5 output alarm relays (SPS841A_015R_D controller).
  • Advanced battery management ORDERInG InFORMATIOn – SlIMlInE P OwER Sy STEM

+-+ USE COUPLER 555052-1 AND G-STYLE CABLE TO DAISY CHAIN B-STYLE CABLE UP TO 150 FEET TO CONTROLLER - -+ + - 48V battery string #1 +-+- -+ + - 48V battery string #2 +-+- -+ + - 48V battery string #3 C CCB TRIM BROWN VOLTAGE SENSE WIRE ON B AND C-STYLE CABLES MAX 16 PROBES +-+ To Controller To Next ES771 - -+ + - 48V battery string #1 +-+- -+ + - 48V battery string #2 +-+- -+ + - 48V battery string #3 ES771 Voltage Module 108958422 CC G G D USE COUPLER 555052-1 TO DAISY CHAIN G-STYLE CABLES UP TO 150 FEET VOLTAGE SENSE WIRE Page 10 Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 Alarm and Communication Cables 5’ Alarm (J1) or distribution (J7) cable CC848890153 15’ Alarm (J1) or distribution (J7) cable CC848865980 50’ Alarm (J1) or distribution (J7) cable CC848817651 5’ Alarm input cable (J2) CC848890203 15’ Alarm input cable (J2) CC848853614 50’ Alarm input cable (J2) CC848890211 Shelf to shelf communication cable (J4) (List 1, 1A only) CC848847780 Battery Box and Accessories Battery box with rack/shelf mounting brackets (3U for 12Ah batteries) CC848903187 Battery box with rack/shelf mounting brackets (6U for 40Ah batteries) CC848870832 IR-40 Battery 408538854 IR-40 cable, 3 1/2 ft., 10ga Wireset, Battery Harness Shelf to Battery Cabinet CC848885715 ES12-12 Battery CC408638183 ES12-12 breaker wireset CC848873546 50A breaker disconnect CC109153202 Wall mount bracket CC848864504 Battery Management Accessories A: QS873A Thermal Probe CC109142980 B: 10’ probe to controller wireset CC848817024 B: 20’ probe to controller wireset CC109157434 C: 1’ probe to probe wireset CC848822560 C: 5’ probe to probe wireset 848719803 C: 10’ probe to probe wireset CC848822321 ES771A Voltage Monitor Card 108958422 D: 2 ½ ‘ ES771A to probe wireset CC848791517 D: 6’ ES771A to probe wireset CC848797290 D: 10’ ES771A to probe wireset 848719829 G: 4’ ES771A to ES771A or controller wireset CC848791500 G: 10’ ES771A to ES771A or controller wireset 848652947 Controller SPS841A_3C3R CC109142238 SPS841A_015R_D with Display CC109156898 Slot Filler (List 1, 1A only) CC848868554 Shelf Options Shelves with 3 rectifier slots, controller slot List 1 Rectifier Only CC109148136 List 1A Rectifier Only CC109146503 Shelves with 2 rectifier slots,1 slot for distribution, controller slot List 2D Rectifier/Distribution CC109165890 List 2AD Rectifier/Distribution CC109165916 List 4 Rectifier/Distribution CC109146511 List 4A Rectifier/Distribution CC109151544 Rectifier EP0500-UTEZ 500W 150027894 EP1000-UTEZ 1000W CC109165602 EP1600-UTEZ 1600W CC109165610 Slot Filler CC848883297 Mounting Brackets 19” to 23” frame mount bracket CC848844803 AC Input, DC Output Cables (105˚C Wire) C13 plug with 5-15P plug, 14AWG, 10’ CC848776105 C13 plug with L6-20P plug, 14AWG, 10’ CC848820317 C13 plug, unterminated, 14AWG, 10’ 847861192 C13 AC Cord Retaining Clamp CC848885698 C19 plug, with 5-15P plug, 12AWG, 8’ CC848850792 C19 plug, with L6-20P plug, 12AWG, 8’ (List

1 Only)

C19 plug, unterminated, 12AWG, 8’ (List 1) CC848847368 C19 AC Cord Retaining Clamp CC848887158 DC output cable 2 AWG, 10’ (List 1, 1A only) 848748987 ORDERInG InFORMATIOn – SlIMlInE P OwER Sy STEM

Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 Mechanical Height 1.71inches (43.4mm) Width (with mounting ears) 19 inches (483mm) Depth 10.37 inches (264mm) Weight (without rectifiers) 6lbs/2.7kg Environmental Operating Temperature Range -40°C to +75°C Operating Relative Humidity 0 - 95% (non-condensing) Storage Temperature Range -40°C to +85°C Agency Certifications CSA Canada/CSA C22.2; cCSAus EMI/EMC FCC Part 15, Class A; EN 55022, Class A (emission); EN 55024 (immunity); EN 55024, levels 3 (CI & RI) and level 4 (ESD) CE CE mark meets Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC NEBs Level 3 certified Shelf Specifications ORDERInG InFORMATIOn – SlIMlInE P OwER Sy STEM

Slimline Power System Brochure © 2013 General Electric Company. All rights reserved.04/13 Contact Us For more information, call us toll free at +1 877 546 3243, or +1 972 244 9288 and visit us on the web at www.gecriticalpower.com ORDERInG InFORMATIOn – SlIMlInE P OwER Sy STEM Management Visibility Galaxy Manager™ software is the centralized visibility and control component of a comprehensive power management system designed to meet engineering, operations and maintenance needs. The Galaxy Manager client-server architecture enables remote access to system controllers across the power network.

  • Dashboard display with one-click access to management information database
  • Trend analysis
  • Scheduled or on demand reports
  • Fault, configuration, asset, and performance management Training GE offers on-site and classroom training options based on certification curriculum. Technical training can be tailored to individual customer needs. Training enables customers and partners to more effectively manage and support the power infrastructure. We have built our training program on practical learning objectives that are relevant to specific technologies or infrastructure design objectives. Service & Support GE field service and support personnel are trusted advisors to our customers – always available to answer questions and help with any project, large or small. Our certified professional services team consists of experts in every aspect of power conversion with the resources and experience to handle large turnkey projects along with custom approaches to complex challenges. Proven systems engineering and installation best practices are designed to safely deliver results that exceed our customers’ expectations. warranty GE is committed to providing quality products and solutions. We have developed a comprehensive warranty that protects you and provides a simple way to get your products repaired or replaced as soon as possible. For full warranty terms and conditions please go to www.gecriticalpower.com.