SPL-53-FE-BX-CDA SOURCE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Features

  • Compliant with OC3/STM-1, IEEE 802.3ah, 100BASE-BX10
  • Simplex LC Connector
  • Digital Diagnostic SFF-8472 Compliant
  • SFP MSA SFF-8074i Compliant
  • 14dB Minimum Power Budget
  • 20km Typical Reach
  • Commercial temperature available (-Cxx)
  • Industrial temperature available (-Txx)
  • Single 3.3V Supply
  • 1530 nm FP Laser
  • Telocordia GR-468 Compliant
  • Color code Bail Latch : Yellow
  • RoHS compliant Parameter Symbol Min. Typ. Max. Unit Supply Voltage Vcc 3.135 3.3 3.465 V Total Current ICC - - 300 mA Power Supply Noise Rejection 100 - - mVp-p Operating Temerature (-Cxx) Topr -5 - 70 ºC Operating Temerature (-Txx) Topr -40 - 85 ºC Storage Temperature Tstg -40 - 85 ºC Data Rate DR 10 - 155 Mbps General Operation Parameter Symbol Min Typical Max Unit Optical power Pop -14 -11 -8 dBm Optical crosstalk XT - -45 -40 dB Average Launch power of off Tx Poff - - -45 dBm Extinction Ratio ER 6.6 - - dB Eye Mask IEEE 802.3 and SONET/SDH Compliant Optical Rise time (20% to 80% values) tr - - 2 ns Optical Fall time (20% to 80% values) tf - - 2 ns Mean Wavelength λ 1480 1530 1580 nm Maximum RMS Width (σ) σ - - 4.6 nm Relative Intensity Noise RIN - - -120 dB/Hz Optical Return Loss Tolerance ORLT - - 12 dB Transmitter Specifications (Optical)

SFP Bi-Directional Transceiver SPL-53-FE-BX Rev A.5 Parameter Symbol Min Typical Max Unit Input Differential Impedence Rin 80 100 120 Ω PECL Single Ended data input swing Vin, p-p 250 - 1200 mV TxFault_Fault Vfault 2 - Vcc V TxFault_Normal Vnormal Vee - Vee + 0.5 V TxDisable_Disable Vd 2 - Vcc V TxDisable_Enable Ven Vee - Vee + 0.8 V Transmitter Specifications (Electrical) Parameter Symbol Min Typical Max Unit Receiver Power Lowa Rsens,low - -30 -28.2 dBm Receiver Power High Rsens,high -8 - - dBm Damage Threshold for Receiver Pin, damage 4 - - dBm Wavelength λ 1260 - 1360 nm LOS Assert - -45 - - dBm LOS De-assert - - - -28.2 dBm LOS hysteresis - 0.5 - - dB a) at 10-12 BER, PRBS 27-1 Receiver Specifications (Optical) Parameter Symbol Min Typical Max Unit PECL Single ended data output swing Vout,p-p 185 - 1000 mV Data output rise time tr - - 2 ns Data output fall time tf - - 2 ns Receiver Specifications (Electrical) Parameter Symbol Min Typical Max Unit Tx Disable Negate time t_on - - 25 ms Tx Disable assert time t_off - - 10 µs Time to initialize, including reset of Tx fault t_init - - 300 ms Tx fault Assert time t_fault - - 100 µs Tx Disable to reset t_reset 10 - - µs LOS Assert time t_loss_on - - 300 µs LOS De-Assert time t_loss_off - - 100 µs Serial ID Clock Rate f_serial_clock - - 100 KHz RX_LOS Voltage (high) Rx_LOSH 2 - - V RX_LOS Voltage (low) RX_LOSL - - 0.8 V LOS output voltage-Fault VLOS fault 2 - Vcc V LOS output voltage-Normal VLOS normal Vee - Vee + 0.5 V MOD_DEF (0:2)-High Vh 2 - Vcc V MOD_DEF (0:2)-Low VI Vee - Vee + 0.5 V Timing and Electrical

SFP Bi-Directional Transceiver SPL-53-FE-BX Rev A.5 Parameter Range Accuracy Unit Calibration Bit Value Formula Temperature (-TDA) -40 to 85 ±3 ºC External 1/256 C Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset Temperature (-CDA) -5 to 70 ±3 ºC External 1/256 C Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset Voltage 0 to Vcc 0.1 V External 100µV V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset Bias Current 0 to 120 5 mA External - I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tx Power -14 to -8 ±3 dB dBm External - Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx Power -28.2 to -8 ±3 dB dBm External - Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4 Digital Diagnostics (-xDA Versions only) Pin Function Notes

1 VeeT TX GND

2 TX_FAULT Open Collector

3 TX_DISABLE Internally Pulled High

4 MOD_DEF2 Serial Data Input

5 MOD_DEF1 Serial Clock Input

6 MOD_DEF0 Internally Grounded

7 NC Not Connected

8 LOS Open Collector

9 VeeR RX Ground

10 VeeR RX Ground

11 VeeR RX Ground

12 RXD- RX Data Negative

13 RXD+ RX Data Positive

14 VeeR RX GND

15 VCCR RX Power

16 VCCT TX Power

17 VeeT TX GND

18 TXD+ TX Data Positive

19 TXD- TX Data Negative

20 VeeT TX GND

Pinout Definitions

SFP Bi-Directional Transceiver SPL-53-FE-BX Rev A.5 Name of Field Discription of Field Address Hex ASCII Vendor Name SFP Vendor name (ASCII) 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C Vendor OUI IEEE vendor OUI code for Luminent Inc. 37 00 38 06 39 B5 Vendor P/N Part number in ASCII, e.g. SPL-53-FE-BX-TDA 40 53 S 41 50 P 42 4C L 43 35 5 44 33 3 45 46 F 46 45 E 47 42 B 48 58 X 49 54 T 50 44 D 51 41 A EEPROM Serial ID

SFP Bi-Directional Transceiver SPL-53-FE-BX Rev A.5 LC Connector Mechanicals Units in mm (inches)

SFP Bi-Directional Transceiver SPL-53-FE-BX Rev A.5 Suggested Transceiver Interface Protocol IC SerDes Laser Driver Receiver Amplifier LuminentOIC SFP Vcc 10F 0.1F .01F VCCT 10K TX_DISABLE TX_FAULT TD + TD - VEET .01F .01F 100 VCCR 10F 0.1F .01F .01F 100 EEPROM MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 RD + RD - RX_LOS TX_DISABLE TX_FAULT RX_LOS R1R1R1 R VEER Vcc R1=4.7K to 10K

SFP Bi-Directional Transceiver SPL-53-FE-BX IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu- ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Warnings: Legal Notes: LUMNDS628-Aug0407 Rev A.5

Ordering Information

S P L - 5 3 - F E - B X - Temperature Diagnostic Revision

  • Wavelength 53 = Tx 1530nm/Rx 1310nm
  • Data Rate FE = Fast Ethernet (100Mbps)
  • D = Digital Diagnostic (SFF-8472) N = No Digital Diagnostic
  • Design Revision A = RoHS compliant
  • Standard BX = 100BASE-BX10
  • Operating Temperature C = Commercial temperature (-5 to 70ºC) T = Industrial temperature (-40 to 85ºC) Available Options:ɹ SPL-53-FE-BX-CDA SPL-53-FE-BX-TDA SPL-53-FE-BX-CNA SPL-53-FE-BX-TNA Part numbering Definition:
  • SPL = LC connector