SPL-34-GB-BD-CDA SOURCE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Features

  • Compatible with IEEE 802.3ah, 1000Base-BX10
  • Simplex LC Connector
  • Digital Diagnostic SFF-8472 Compliant
  • SFP MSA SFF-8074i Compliant
  • 19dB Minimum Power Budget
  • 40km Minimum Reach
  • Commercial temperature available (-Cxx)
  • Industrial temperature available (-Txx)
  • Single 3.3V Supply
  • 1310nm DFB Laser
  • Telcordia GR-468 Compliant
  • Color code Bail Latch : Blue
  • RoHS compliant (lead free soldered) Parameter Symbol Min. Typ. Max. Unit Supply Voltage Vcc 3.135 3.3 3.465 V Total Current ICC - - 300 mA Power Supply Noise Rejection 100 - - mVp-p Operating Temperature (-CxA) Topr -5 - 70 ºC Operating Temperature (-TxA) Topr -40 - 85 ºC Storage Temperature Tstg -40 - 85 ºC Data Rate DR - 1250 - Mbps General Operation Parameter Symbol Min Typical Max Unit Optical Power Pop -5 -2.5 0 dBm Optical Crosstalk XT - -45 -40 dB Average Launch Power (Tx:Off) Poff - - -45 dBm Extinction Ratio ER 9 - - dB Eye Mask IEEE 802.3ah Compliant Optical Rise Time (20% to 80% values) tr - - 260 ps Optical Fall Time (20% to 80% values) tf - - 260 ps Mean Wavelength λ 1260 1310 1360 nm Spectral Width (20dB) ∆λ - - 1 nm Relative Intensity Noise RIN - - -120 dB/Hz Transmitter Reflectance - - - -12 dB Reflection Tolerance rp 12 - - dB Transmitter Specifications (Optical)

SFP Bi-Directional Transceiver SPL-34-GB-BD LUMINENTOIC.COM LUMNDS1579-Jun1407 Rev A.3 Parameter Symbol Min Typical Max Unit Input Differential Impedence Rin 80 100 120 Ω PECL Single-Ended Data Input Swing Vin, p-p 250 - 1200 mV TxFault_Fault Vfault 2 - Vcc V TxFault_Normal Vnormal Vee - Vee + 0.5 V TxDisable_Disable Vd 2 - Vcc V TxDisable_Enable Ven Vee - Vee + 0.8 V Transmitter Specifications (Electrical) Parameter Symbol Min Typical Max Unit Receiver Power Lowa Rsens,low - -26 -24 dBm Receiver Power Higha Rsens,high -3 - - dBm Damage Threshold for Receiver Pin, damage 0 - - dBm Wavelength λ 1480 - 1580 nm LOS Assert - -45 - - dBm LOS De-Assert - - - -24 dBm LOS Hysteresis - 0.5 - - dB Receiver Reflectance - - - -12 dB a) Measured at 10-12 BER, PRBS 27-1, 6dB ER Receiver Specifications (Optical) Parameter Symbol Min Typical Max Unit PECL Single-Ended Data Output Swing Vout,p-p 185 - 800 mV Data Output Rise Time tr - - 500 ps Data Output Fall Time tf - - 500 ps Receiver Specifications (Electrical) Parameter Symbol Min Typical Max Unit Tx Disable Negate Time t_on - - 1 ms Tx Disable Assert Time t_off - - 10 µs Time to Initialize, Including Reset of Tx Fault t_init - - 300 ms Tx Fault Assert Time t_fault - - 100 µs Tx Disable to Reset t_reset 10 - - µs LOS Assert Time t_loss_on - - 100 µs LOS De-Assert Time t_loss_off - - 100 µs Serial ID Clock Rate f_serial_clock - - 100 KHz RX_LOS Voltage (High) Rx_LOSH 2 - - V RX_LOS Voltage (Low) RX_LOSL - - 0.8 V LOS Output Voltage-Fault VLOS fault 2 - Vcc V LOS Output Voltage-Normal VLOS normal Vee - Vee + 0.5 V MOD_DEF (0:2)-High Vh 2 - Vcc V MOD_DEF (0:2)-Low VI Vee - Vee + 0.5 V Timing and Electrical

SFP Bi-Directional Transceiver SPL-34-GB-BD LUMINENTOIC.COM LUMNDS1579-Jun1407 Rev A.3 Parameter Range Accuracy Unit Calibration Bit Value Formula Temperature (-CDA) -5 to 70 ±3 ºC Internal 1/256 C Tc(C) = Tad(16 bit signed twos complement)/256 Temperature (-TDA) -40 to 85 ±3 ºC Internal 1/256 C Tc(C) = Tad(16 bit signed twos complement)/256 Voltage 0 to Vcc .1 V Internal 100µV V(Volts) = Vad(16 bit unsigned integer)*0.1 Bias Current 0 to 120 5 mA External - I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tx Power -5 to 0 ±3 dBm External - Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx Power -24 to -3 ±3 dBm External - Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4 Diagnostics Name of Field Discription of Field Address Hex ASCII Vendor Name SFP Vendor name (ASCII) 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C Vendor OUI IEEE vendor OUI code for LuminentOIC 37 00 38 06 39 B5 Vendor P/N Part number in ASCII, e.g. SPL-34-GB-BD-CDA 40 53 S 41 50 p 42 4C L 43 33 3 44 34 4 45 47 G 46 42 B 47 42 B 48 44 D 49 43 C 50 44 D 51 41 A EEPROM Serial ID

SFP Bi-Directional Transceiver SPL-34-GB-BD LUMINENTOIC.COM LUMNDS1579-Jun1407 Rev A.3 Pin Function Notes

1 VeeT TX GND

2 TX_FAULT Open Collector

3 TX_DISABLE Internally Pulled High

4 MOD_DEF2 Serial Data Input

5 MOD_DEF1 Serial Clock Input

6 MOD_DEF0 Internally Grounded

7 NC Not Connected

8 LOS Open Collector

9 VeeR RX Ground

10 VeeR RX Ground

11 VeeR RX Ground

12 RXD- RX Data Negative

13 RXD+ RX Data Positive

14 VeeR RX GND

15 VCCR RX Power

16 VCCT TX Power

17 VeeT TX GND

18 TXD+ TX Data Positive

19 TXD- TX Data Negative

20 VeeT TX GND

Pinout Definitions

SFP Bi-Directional Transceiver SPL-34-GB-BD LUMINENTOIC.COM LUMNDS1579-Jun1407 Rev A.3 Suggested Transceiver Interface Mechanicals Units in mm (inches)

SFP Bi-Directional Transceiver SPL-34-GB-BD LUMINENTOIC.COM LUMNDS1579-Jun1407 Rev A.3 Protocol IC SerDes Laser Driver Receiver Amplifier LuminentOIC SFP Vcc 10F 0.1F .01F VCCT 10K TX_DISABLE TX_FAULT TD + TD - VEET .01F .01F 100 VCCR 10F 0.1F .01F .01F 100 EEPROM MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 RD + RD - RX_LOS TX_DISABLE TX_FAULT RX_LOS R1R1R1 R VEER Vcc R1=4.7K to 10K Suggested Transceiver Interface

IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at Luminent’s sole and absolute discretion. Luminent warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and Luminent makes no representa- tions or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. Luminent customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify Luminent for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that Luminent is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © Luminent, Inc. 2003 All rights reserved Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. SFP Bi-Directional Transceiver SPL-34-GB-BD Rev A.3 Warnings: Legal Notes:

Ordering Information

SPL - 34 - GB - BD - Temperarure Diagnostic Revision

  • Wavelength 34 = Tx 1310nm/Rx 1490nm
  • Data Rate GB = Gigabit Ethernet
  • D = Digital Diagnostic (SFF-8472) N = No Digital Diagnostic
  • Revision A = RoHS compliant (lead free soldered)
  • Standard BD = 1000BASE-BX10, 40km
  • Operating Temperarure C = Commercial temperature (-5 t o 70ºC) T = Industrial temperature (-40 to 85ºC) Available Options:ɹ SPL-34-GB-BD-CDA SPL-34-GB-BD-CNA Part Numbering Definition:
  • SPL = LC connector ɹ SPL-34-GB-BD-TDA SPL-34-GB-BD-TNA