021 3 B U -SB 1 31 45 Page 1 of 4 D ata Sheet 21 6 3 w w w .cooperbussm ann.com /Surge SURGE PROTECTION M ADE SIM PLE ™ FOR COM M ERCIAL & I NDUSTRIAL APPLICATIONS SURGE POD™ HEAVY DUTY SPD FOR UL 1449 3 rd Edition Listed Loadside and Lineside Protection 2-1/16” 2-1/16” 1-11/16” 1-11/16” 4-1/8” 3-3/16” 4-1/16” 3-3/8” 7/8” 1-1/16” Dia. NEM A 4 X Rated Heavy Duty Type 1 UL Listed SPD

Description

The C ooper Bussm ann SurgePO D ™ HEAVY D U TY is a Type 1 U L L isted 1449 3 rd Edition surge protective device suitable for installation on both the loadside or lineside of the service entrance overcurrent protective device. Available in voltage and system specific versions to m atch electrical system and equipm ent requirem ents. The SurgePO D HEAVY D U TY delivers optim um surge protection using advanced patent pending SurgePO D ™ m odule featuring therm al disconnect technology that elim inates the need for additional overcurrent protection. Parallel connection to the electrical system perm its the SurgePO D HEAVY D U TY SPD to be installed on any am pacity panel.

  • Type 1 U L 1449 3 rd Edition L isted SPD s are easily selected and installed on the loadside or lineside of the service entrance overcurrent protective device
  • Patented C ooper Bussm ann SurgePO D m odule technology elim inates the need for additional fusing
  • Voltage specific m odels precisely m atch and protect electrical system s and equipm ent up to 600Vac
  • C om pact U V resistant N EM A 4X for indoor or outdoor

applications

  • easy ID ™ L ED status indicator provides surge protection status at a glance D im ensions - in SPH50SP1120SN SPH50SP124 0SN SPH50SP134 7SN SPH50SP2120SNG SPH50SP224 0SNG SPH50SP234 7SNG SPH50SP224 0PN SPH50SP24 80PN SPH50SP324 0PNG SPH50SP34 80PNG SPH50SP324 0DLG SPH50SP34 80DLG SPH50SP4 24 0HLG SPH50SP4 4 80HLG SPH50SP3208W YG SPH50SP34 80W YG SPH50SP36 00W YG SPH50SP4 208W YNG SPH50SP4 4 80W YNG SPH50SP4 6 00W YNG easy ID ™ L ED Status Indicator Type 1 SPD Part Num ber System SPH 50S PX XXX XXX SPH = Product Series Surge Protection Heavy D uty Surge Rating 5 0S = 5 0kA m ax discharge current No of W ires/Poles P1 = 1 P2 = 2 P3 = 3 P4 = 4 Rated System Voltage 12 0, 2 08, 2 40, 347 , 480, 600Vac System SN = Single-Phase 2 W ire, 2 C onnection Points SN G = Single-Phase 2 W ire + G , 3 C onnection Points PN = Split-Phase 3 W ire , 3 C onnection Points PN G = Split-Phase 3 W ire + G , 4 C onnection Points D L G = Three-Phase D elta 3 W ire + G , 4 C onnection Points HL G = Three-Phase Highleg D elta 4 W ire + G , 5 C onnection Points W YG = Three-Phase W ye 3 W ire, 4 C onnection Points W YN G = Three-Phase W ye 3 W ire + G , 5 C onnection Points SPD Type 2

021 3 B U -SB 1 31 45 Page 2 of 4 D ata Sheet 21 6 3 SurgePO D ™ H EAVY D U TY Technical Inform ation N om inal M ax. C ontinuous System O perating AC C onnection C atalog N um ber Voltage Voltage (M C O V) (V C ) System Type Points SPH5 0SP112 0SN 12 0V 15 0V Single-Phase 2 W ire 2 SPH5 0SP12 40SN 2 40V 32 0V Single-Phase 2 W ire 2 SPH5 0SP1347 SN 347 V 42 0V Single-Phase 2 W ire 2 SPH5 0SP2 12 0SN G 12 0V 15 0V Single-Phase 2 W ire + G 3 SPH5 0SP2 2 40SN G 2 40V 32 0V Single-Phase 2 W ire + G 3 SPH5 0SP2 347 SN G 347 V 42 0V Single-Phase 2 W ire + G 3 SPH5 0SP2 2 40PN 12 0/2 40V 15 0V Split-Phase 3 W ire 3 SPH5 0SP2 480PN 2 40/480V 32 0V Split-Phase 3 W ire 3 SPH5 0SP32 40PN G 12 0/2 40V 15 0V Split-Phase 3 W ire + G 4 SPH5 0SP3480PN G 2 40/480V 32 0V Split-Phase 3 W ire + G 4 SPH5 0SP32 40D L G 2 40V 32 0V Three-Phase D elta 3 W ire + G 4 SPH5 0SP3480D L G 480V 5 5 0V Three-Phase D elta 3 W ire + G 4 SPH5 0SP42 40HL G 12 0/2 40V 15 0/32 0V Three-Phase Highleg D elta 4 W ire + G 5 SPH5 0SP4480HL G 2 40/480V 32 0/5 5 0V Three-Phase Highleg D elta 4 W ire + G 5 SPH5 0SP32 08W YG 2 08V 15 0V Three-Phase W ye 3 W ire + G 4 SPH5 0SP3480W YG 480V 32 0V Three-Phase W ye 3 W ire + G 4 SPH5 0SP3600W YG 600V 42 0V Three-Phase W ye 3 W ire + G 4 SPH5 0SP42 08W YN G 2 08Y/12 0V 15 0V Three-Phase W ye 4 W ire + G 5 SPH5 0SP4480W YN G 480Y/2 7 7 V 32 0V Three-Phase W ye 4 W ire + G 5 SPH5 0SP4600W YN G 600Y/347 V 42 0V Three-Phase W ye 4 W ire + G 5 Specifications (for all SurgePO D H D units) Values Short C ircuit C urrent Rating (SC C R) 2 00kA N om inal D ischarge C urrent (8x2 0µs) I n 2 0kA M ax. D ischarge C urrent (8x2 0µs) I m ax 5 0kA Response Tim e t A <2 5 ns Frequency 5 0/60Hz O perating State/Fault Indication Bi-C olor L ED - G reen (good) / Red (replace) C onductor L ength / G uage 18 inches, 10 AW G Stranded Tinned C opper M ounting C hase N ipple / Bracket* Enclosure / Flam m ability Ratings N EM A 4X - U L 94-5 VA D egree of Protection (Installed State) IP2 0 (finger-safe) SPD Install L ocation Indoor/O utdoor C ircuit L ocation L ineside or L oadside of service entrance overcurrent protective device Standard U L 1449 3 rd Edition Type 1 L isted SPD A gency Inform ation cU L us, C SA , RoHS C om pliant Product W arranty 5 Years* O perating Tem perature -40˚C to +85 ˚C M axim um O perating A ltitude 16,000FT * C ustom er-supplied bracket. 6 00V W ye versions not C SA C ertified. * See C ooper B ussm ann SPD Lim ited W arranty Statem ent (3A1 502) for details at w w w .cooperbussm ann.com / Surge . SurgePO D ™ H EAVY D U TY Technical Inform ation † 6 00V W ye versions are not C SA C ertified.

021 3 B U -SB 1 31 45 Page 3 of 4 D ata Sheet 21 6 3 R ated System M C O V Voltage Protection R atings (VPR s) C atalog N um ber Voltage (V o) (V C ) L-N L-L L-G N -G SPH5 0SP112 0SN 12 0V 15 0V 7 00 —— — SPH5 0SP12 40SN 2 40V 32 0V 12 00 —— — SPH5 0SP1347 SN 347 V 42 0V 15 00 —— — SPH5 0SP2 12 0SN G 12 0V 15 0V 7 00 — 12 00 7 00 SPH5 0SP2 2 40SN G 2 40V 32 0V 12 00 — 2 5 00 12 00 SPH5 0SP2 347 SN G 347 V 42 0V 15 00 — 2 5 00 15 00 SPH5 0SP2 2 40PN 12 0V/2 40V 15 0V 7 00 12 00 —— SPH5 0SP2 480PN 2 40V/480V 32 0V 12 00 2 5 00 —— SPH5 0SP32 40PN G 12 0V/2 40V 15 0V 7 00 12 00 12 00 7 00 SPH5 0SP3480PN G 2 40V/480V 32 0V 12 00 2 5 00 2 5 00 12 00 SPH5 0SP32 40D L G 2 40V 32 0V — 2 5 00 12 00 — SPH5 0SP3480D L G 480V 5 5 0V — 3000 1800 — SPH5 0SP42 40HL G 12 0/2 40V 15 0V/32 0V 7 00/12 00 12 00/2 5 00 12 00/2 5 00 7 00/12 00 SPH5 0SP4480HL G 2 40/480V 32 0V/5 5 0V 12 00/1800 2 5 00/3000 2 5 00/3000 12 00/1800 SPH5 0SP32 08W YG 2 08V 15 0V — 12 00 7 00 — SPH5 0SP3480W YG 480V 32 0V — 2 5 00 12 00 — SPH5 0SP3600W YG 600V 42 0V — 2 5 00 15 00 — SPH5 0SP42 08W YN G 2 08Y/12 0V 15 0V 7 00 12 00 12 00 7 00 SPH5 0SP4480W YN G 480Y/2 7 7 V 32 0V 12 00 2 5 00 2 5 00 12 00 SPH5 0SP4600W YN G 600Y/347 V 42 0V 15 00 2 5 00 2 5 00 15 00 Voltage Protection R atings (VPR s) easy ID ™ LED Status Indicator The easy ID ™ L ED status indicator w ill illum inate w hen the unit is properly installed and the system or equipm ent being protected is energized. The follow ing L ED color/status indicates: G R EEN LED = G ood The circuit is energized and protected . R ED LED = R eplace The circuit is energized and unprotected . The unit needs replacing. LED is O ut / U nlit:

  • T he circuit is m ost likely deenergized
  • The unit’s leads are disconnected
  • The unit is dam aged Authorized personnel should follow all prescribed lockout/tagout and safety procedures in troubleshooting the cause for the above conditions. O pening SurgePO D HEAVY D U TY enclosure w ill void U L listing and w arranty. Tighten locknut to 20.3 Lb-In (2.3N•m) For NEMA 4X installation, install appropriate customer supplied gasket between SurgePOD™ HEAVY DUTY SPD and enclosure wall. M ounting SurgePO D HEAVY D U TY is a panel m ount device. It m ay also be m ounted using a custom er supplied bracket or directly onto a fem ale threaded conduit fitting. † 6 00V W ye versions are not C SA C ertified.

02 13 BU -SB13145 Page 4 of 4 D ata Sheet 2 163 © 2 013 C oop er Bussm ann w w w .coop erb ussm ann.com The only controlled copy of this D ata Sheet is the electronic read-only version located on the C ooper B ussm ann N etw ork D rive. All other copies of this docum ent are by definition uncontrolled. This bulletin is intended to clearly present com prehensive product data and provide technical inform ation that w ill help the end user w ith design applications. C ooper B ussm ann reserves the right, w ithout notice, to change design or construction of any products and to discontinue or lim it distribution of any products. C ooper B ussm ann also reserves the right to change or update, w ithout notice, any technical inform ation contained in this bulletin. O nce a product has been selected, it should be tested by the user in all possible applications. W iring Connections Black Black White L1 (Black) L2 (Black) N (White) 240V (L-N ) / 48 0V (L1 -L2) Single Phase (Split) C enter Tap SPH50SP224 0PN, SPH50SP24 80PN Black Black Green White Orange L3 (Black) L2 (Orange) Highleg L1 (Black) N (White) GND (Green)

4 W ire H ighleg D elta + G round

SPH50SP4 24 0HLG, SPH50SP4 4 80HLG L (Black) N (White) Black White 1 20, 240, 347V (L-N )

2 W ire

1 20, 240, 347V (L-N )

2 W ire + G round

SPH50SP1120SN, SPH50SP124 0SN, SPH50SP134 7SN L (Black) N (White) GND (Green) Black Green White SPH50SP2120SNG, SPH50SP224 0SNG, SPH50SP234 7SNG Black Black Black Green White GND (Green) L2 (Black) N (White) L3 (Black) L1 (Black) SPH50SP4 208W YNG, SPH50SP4 4 80W YNG, SPH50SP4 6 00W YNG 1 20V (L-N ) / 208 V (L-L),

4 W ire W ye + G round

L1 (Black) L2 (Black) L3 (Black) GND (Green) SPH50SP324 0DLG, SPH50SP34 80DLG Black Black Black Green 240, 48 0V (L-L)

3 W ire D elta + G round

L1 (Black) L3 (Black) L2 (Black) GND (Green) SPH50SP3208W YG, SPH50SP34 80W YG, SPH50SP36 00W YG 208 , 48 0, 6 00V (L-L)

3 W ire W ye + G round

L1 (Black) L2 (Black) N (White) GND (Green) 240V (L-N ) / 48 0V (L1 -L2) Single Phase (Split) C enter Tap + G round SPH50SP324 0PNG, SPH50SP34 80PNG M ust be installed w ithin 1 0 feet (3m ) of a bonded neutral-ground connection per IEEE C 6 2.41 -1 991 For installations at or less than 1 0 feet (3m ) from the transform er. For installation w hen located greater than 1 0 feet (3m ) of a bonded neutral-ground connection. For installation w hen located greater than 1 0 feet (3m ) of a bonded neutral-ground connection. Single-Phase Tw o-Pole w ith Neutral Tw o-Pole w ith Neutral + Ground W ye + Ground W ye w ith Neutral + Ground Delta + Ground Highleg Delta Single-Phase + Ground