15A (2C), 10A (4C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY .866 a 1.969 mm inch a 25.6 1.008 36.8 1.449

FEATURES

  • High Vibration/Shock Resistance Vibration resistance: 18 G, amplitude 3 mm (10 to 55 Hz) Shock resistance: 40 G (11 ms)
  • Latching types available
  • High Sensitivity in Small Size 150 mW pick-up, 300 mW nominal operating power
  • Wide Switching Range From 1 mA to 15 A (2C) and 10 A (4C) SPECIFICATIONS Contacts Coil (polarized) at 20 C 68 F Characteristics (at 25 C 77 F 50% Relative humidity) Remarks * Specifications will vary with foreign standards certification ratings. Measurement at same location as "Initial breakdown voltage" section Detection current: 10 mA Excluding contact bounce time Half-wave pulse of sine wave: 11ms; detection time: 10 µ s Half-wave pulse of sine wave: 6ms Detection time: 10 µ s Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61). Arrangement

2 Form C, 4 Form C

Initial contact resistance, max. (By voltage drop 6 V DC 1 A) 30 m Ω Initial contact pressure 2C: Approx. 0.392 N (40 g 1.41 oz ) 4C: Approx. 0.196 N (20 g 0.71 oz ) Contact material Stationary contact: Gold flashed silver alloy Movable contact: Silver alloy Rating (resistive load) Nominal switching capacity 2C: 15 A 250 V AC

10 A 30 V DC

4C: 10 A 250 V AC Max. switching power 2C: 3,750 VA, 300 W 4C: 2,500 VA, 300 W Max. switching voltage 2C, 4C: 250 V AC, 30 V DC Max. switching current 2C: 15 A (AC) 10 A (DC), 4C: 10 A Expected life (min. operations) Mechanical (at 180 cpm) Electrical (at 20 cpm) (resistive load)

15 A 250 V AC

10 A 250 V AC

Minimum set and reset power 150 mW Nominal set and reset power 300 mW Max. operating speed (at rated load) 20 cpm Initial insulation resistance* 1,000 M Ω at 500 V DC Initial breakdown voltage* Between open contacts 1,500 Vrms Between contact sets 3,000 Vrms Between contact and coil 3,000 Vrms Operate time* (at nominal voltage) Max. 30 ms (Approx. 25 ms) Release time(without diode)* (at nominal voltage) Max. 20 ms (Approx. 15 ms) Temperature rise (at nominal voltage) Max. 40 C with nominal coil voltage and at nominal switching capacity Shock resistance Functional* Min. 392 m/s {40 G} Destructive* Min. 980 m/s {100 G} Vibration resistance Functional* 176.4 m/s {18 G}, 10 to 55 Hz at double amplitude of 3 mm Destructive 176.4 m/s {18 G}, 10 to 55 Hz at double amplitude of 3 mm Conditions for operation, transport and storage* (Not freezing and condens- ing at low temperature) Ambient temp. –50 C to +60 C –58 F to +140 F Humidity 5 to 85% R.H. Unit weight 2C: 50 g 1.76 oz ; 4C: 65 g 2.29 oz TYPICAL APPLICATIONS NC machines, remote control panels, sophisticated business equipment.

ORDERING INFORMATION

2: 2 Form C 4: 4 Form C Nil: Single side stable L2: 2 coil latching DC 3, 5, 6, 12, 24, 48 V DC24V SP Ex. (Notes) 1. PC board terminal types available as option. Please consult us for details. 2. 2 Form C: Carton: 20 pcs., Case: 200 pcs. 4 Form C: Carton: 10 pcs., Case: 100 pcs. 3. UL/CSA, TÜV approved type is standard.

TYPES AND COIL DATA (at 20 C 68 Single side stable 2-coil latching Part No. Nominal voltage, V DC Pick-up voltage, V DC (max.) Drop-out voltage, V DC (min.) Nominal operating current, mA Coil resis- tance, Ω 10%) 20 C Inductance, H (at 120 Hz) Nominal operating power, mW Maximum allowable voltage, V DC (40

2 Form C

4 Form C

2.1 0.3 100.0 Approx. 0.05 300 4.5 SP2-DC5V SP4-DC5V 3.5 0.5 60.2 0.1 300 7.5 SP2-DC6V SP4-DC6V 4.2 0.6 50.0 120 0.2 300 SP2-DC12V SP4-DC12V 8.4 1.2 25.0 480 0.7 300 SP2-DC24V SP4-DC24V 16.8 2.4 12.5 1,920 3.0 300 SP2-DC48V SP4-DC48V 33.6 4.8 6.2 7,700 11.2 300 Part No. Nominal voltage, V DC Set and reset voltage, V DC (max.) Nominal operating current, mA Coil resistance, Ω 10%) Inductance, H (at 120 Hz) Nominal operating power, mW Maximum allowable voltage, V DC (40 2.1 100.0 Approx. 0.03 Approx. 0.03 300 4.5 SP2-L2-DC5V SP4-L2-DC5V 3.5 60.2 0.07 0.07 300 7.5 SP2-L2-DC6V SP4-L2-DC6V 4.2 50.0 120 120 0.1 0.1 300 SP2-L2-DC12V SP4-L2-DC12V 8.4 25.0 480 480 0.4 0.4 300 SP2-L2-DC24V SP4-L2-DC24V 16.8 12.5 1,920 1,920 1.4 1.4 300 SP2-L2-DC48V SP4-L2-DC48V 33.6 6.2 7,680 7,680 5.6 5.6 300 DIMENSIONS mm inch General tolerance: 0.3 .012 1.969 .039 25.6 1.008 20.5 .807 7.15 .281 1.5 .059 .394 10.16 .400 4.75 .187 10.16 .400 10.16 .400 10.16 .400 15.24 .600 0.5 .020 FASTON #187 Schematic (Bottom view) Single side stable (Deenergized condition) 2 coil latching (Reset condition) Diagram shows the "reset" position when terminals 3 and 4 are energized. Energize terminals 1 and 2 to transfer contacts. SET RST General tolerance: 0.3 .012 1.969 .039 36.8 1.449 20.5 .807 7.15 .281 1.5 .059 .394 10.16 .400 4.75 .187 10.16 .400 10.16 .400 10.16 .400 15.24 .600 0.5 .020 7.62 .300 7.62 .300 Schematic (Bottom view) Single side stable (Deenergized condition) 2 coil latching (Reset condition) Diagram shows the "reset" position when terminals 3 and 4 are energized. Energize terminals 1 and 2 to transfer contacts. SET RST

Operate and release time (Single side stable) SP2 SP4 Coil temperature rise Sample: SP2-DC24V Ambient temperture: 20 to 22 C 68 to 72 F Coil applied voltage,%V Operate/release time, ms Max. Max. Min. Min. Operate time Release time 110 100 Coil applied voltage,%V Operate/release time, ms Max. Max. Min. Min. Operate time Release time 110 100 Coil applied voltage,%V 19.2 21.6 24.0 Temperature rise, °C 15 A 10 A 5 A 0 A Sample: SP4-DC24V Ambient temperature: 27 to 29 C 81 to 84 F load) Coil applied voltage,%V 19.2 21.6 24.0 Temperature rise, °C 10 A 5 A 0 A Pick-up/drop-out voltage, V No. of operations, ×10 Drop-out voltage Pick-up voltage x x Max. Max. Min. Min. Contact resistance, mΩ N.C. N.O. No. of operations, ×10 x x Max. Max. Min. Min. load) Pick-up/drop-out voltage, V No. of operations, ×10 Drop-out voltage Pick-up voltage x x Max. Max. Min. Min. Contact resistance, mΩ No. of operations, ×10 x Max. Min. N.C. N.O.

38±0.6 1.496±.024 35±0.6 1.378±.024 23±1 .906±.039 7.5±0.3 .295±.012 20.32±0.4 .800±.016 40.64±0.4 1.600±.016 56±1 2.205±.039 48±1 1.890±.039 15.24±0.4 .600±.016 4.5±0.3 .177±.012 R2.25 R.089 12±0.3 .472±.012 5±0.3 .197±.012 7.7±0.3 .303±.012 24.5±0.4 .965±.016 52.8±0.6 2.079±.024 MADE IN JAPAN 48±0.6 1.890±.024 7.5±0.3 .295±.012 23±1 .906±.039 20.32±0.4 .800±.016 40.64±0.4 1.600±.016 56±1 2.205±.039 60±1 2.362±.039 30.48±0.4 1.200±.016 4.5±0.3 .177±.012 R2.25 R.089 12±0.3 .472±.012 5±0.3 .197±.012 7.7±0.3 .303±.012 38±0.6 1.496±.024 52.8±0.6 2.079±.024 15.24±0.4 .600±.016 MADE IN JAPAN Wrapping socket SP2-WS SP4-WS 38±0.6 1.496±.024 35±0.6 1.378±.024 23±1 .906±.039 7.5±0.3 .295±.012 20.32±0.4 .800±.016 40.64±0.4 1.600±.016 56±1 2.205±.039 48±1 1.890±.039 15.24±0.4 .600±.016 4.5±0.3 .177±.012 12±0.3 .472±.012 5±0.3 .197±.012 52.8±0.6 2.079±.024 l1.5 l.059 25±0.4 .984±.016 R2.25 R.089 24.5±0.4 .965±.016 MADE IN JAPAN 48±0.6 1.890±.024 7.5±0.3 .295±.012 23±1 .906±.039 20.32±0.4 .800±.016 40.64±0.4 1.600±.016 56±1 2.205±.039 60±1 2.362±.039 30.48±0.4 1.200±.016 4.5±0.3 .177±.012 R2.25 R.089 12±0.3 .472±.012 5±0.3 .197±.012 15.24±0.4 .600±.016 38±0.6 1.496±.024 25±0.4 .984±.016 52.8±0.6 2.079±.024 l1.5 l.059 MADE IN JAPAN Mounting hole drilling diagram 53.7±0.2 2.114±.008 35±0.2 1.378±.008 25.2±0.2 .992±.008 38±0.2 1.496±.008 2-DIA. HOLES 5.0±0.1 2-DIA. HOLES .197±.004 53.7±0.2 2.114±.008 48±0.2 1.890±.008 38.9±0.2 1.531±.008 2-DIA. HOLES 5.0±0.1 2-DIA. HOLES .197±.004 Notes: (1) Mounting screws and the fastening bracket are included in the package. (2) Mount the relay with the proper mount- ing direction — i.e. with the direction of the NAIS mark on top of the relay case match- ing the direction of the NAIS mark on the terminal block. (The direction of the terminal block is the upward direction of the relay.) Performance profile Note: Do not remove the relay while it is ON. Item SP2, socket with solder SP4, socket with solder SP2, wrap- ping socket SP4, wrap- ping socket Withstand volt- age AC 3,000V, 1 min., between each terminal Insulation resistance 1,000 M Ω min Ambient working temperature –50 to +60 C –58 to +140 Maximum current, ON current 15 A 10 A 12 A 10 A

Mounting and removal of fastening bracket 1. Mounting Insert the A part of the fastening bracket into the mounting groove of the socket, and then fit the B part into groove, while pressing with the tip of a minus screwdriv- er. 2. Removal Slide the B part of the fastening bracket from the groove in the socket, while press- ing with the tip of a minus screwdriver. While the bracket is in this position, keep pressing the C part of the bracket to the relay side with your finger, and lift up to the left side and remove from the groove, as in the diagram at right. B C Minus screwdriver A Fastening bracket SP relay Terminal block Screw terminal socket 40.64±0.4 1.600±.016 19.5±0.6 .768±.024 23±1 .906±.039 20.32±0.4 .800±.016 67±1 2.638±.039 15.24±0.4 .600±.016 52±1 2.047±.039 30±0.6 1.181±.024 4.5±0.4 .177±.016 6.5±0.4 .256±.016 mm inch 40.64±0.4 1.600±.016 20.32±0.4 .800±.016 97±1 3.819±.039 52±1 2.047±.039 30±0.6 1.181±.024 4.5±0.3 .177±.012 6.5±0.3 .256±.012 30.48±0.4 1.200±.016 15.24±0.4 .600±.016 23±1 .906±.039 32±0.6 1.260±.024 19.5±0.6 .768±.024 40.5±0.6 1.594±.024 70.5±1 2.776±.039 11±0.4 .433±.016 21±0.4 .827±.016 Mounting hole drilling diagram Notes: (1) Mounting screws and the fastening bracket are included in the package. (2) Mount the relay with the proper mount- ing direction — i.e. with the direction of the NAIS mark on top of the relay case match- ing the direction of the NAIS mark on the terminal block. (The ; direction of the terminal block is the upward direction of the relay.) Fastening bracket mounting and removal 1. Mounting Insert the A part of the fastening bracket into the mounting groove of the terminal block, and then fit the B part into groove, while pressing with the tip of a minus screwdriver. 2. Removal Slide the B part of the fastening bracket from the groove in the terminal block, while pressing with the tip of a minus screwdriver. While the bracket is in this position, keep pressing the C part of the bracket to the relay side with your finger, and lift up to the left side and remove from the groove, as in the diagram at right. 30±0.2 1.181±.008 2-DIA. HOLES 4.5±0.1 2-DIA. HOLES .177±.004 B C Minus screwdriver A Fastening bracket SP relay Terminal block Mounting plate SP-MA 18.4 .724 .984 23.2 .913 57.2 2.252 The SP-Relay with SP-MA attached Direct chassis mounting possible, and applicable to DIN rail. [DIN 46277 (35 mm width) is applicable.] Tolerance: ±0.1 ±.004 18.4 .724 2-DIA. HOLES 3.2 2-DIA. HOLES .126 Panel cutout

  1. Both the SP relay 2c and 4c can be mounted to the mounting slats. 2. Use the mounting slats either by attach- ing them directly to the chassis, or by mounting with a DIN rail. (A) When attaching directly to chassis Use two M3 screws. For the mounting pitch, refer to the speci- fication diagram. (B) When mounting on a DIN rail Use a 35mm 1.378inch wide DIN rail (DIN46277). The mounting method should be as indi- cated in the diagram at right. Method for mounting on DIN rail (1) First fit the arc shaped claw of the mounting slat into the DIN rail. (2) Press on the side as shown in the dia- gram below. (3) Fit in the claw part on the opposite side. Precautions for use When mounting to a DIN rail, use a com- mercially available fastening bracket if there is a need to stop sliding of the mounting slat in the rail direction. Press relay in Fit into mounting grooves. Press Mounting slat DIN rail Fig. 3 Fig. 2 Fig. 1 Fit in To remove the relay, press down the mounting slats so the claws move to the outside. For Cautions for Use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog