SP361 SIPAT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

For DECT First IF Filters (F-11 Package) Electrical Characteristic: Characteristic Sym Unit Spec Nominal Center Frequency F0 MHz 361.65 3dB Bandwidth(from f0) ΔF3dB KHz ±500 Stop Band Attenuation (from peak level) 1) at F0-20MHz 2) at F0-10MHz 3) at F0±4.00MHz 4) at F0±10MHz 5) at F0+30MHz dB 50min 35min 10min 20min 50min Insertion Loss(at minimum loss point) IL dB 3.5max Group Delay Deviation(with F0±500kHz) ΔT us 0.7max Input/Output Impedance (Nominal) See fig1 Input/Output Impedance(fig1): F -11 Package(fig2): L1=12nH This may be changed according to PCB Frequency Characteristic(fig3): SP361 320 330 340 350 360 370 380 390 400 -70 -60 -50 -40 -30 -20 -10 Type performance Frequency(MHz) Magnitude(dB)