200W Single Output with PFC Function SP200 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 Universal AC input Protections:Short circuit/Over load/Over voltage/Over temperarure Built-in active PFC function, PF >0.93 Built-in cooling fan speed control Built-in constant current limiting circuit Built-in fan speed control Fixed switching frequency at PFC:67KHz PWM:134KHz LED indicator for power on Model Number Output Volts Output Amps OVP Min Load DC Volt Adjust Efficiency SINGLE OUTPUT SP200-5 5 Volts(DC) 40 Amps 5.5 ~ 6.75Volt(DC) 0~40Amps 4.75~5.5Volt(DC) 71%

200W Single Output with PFC Function SP200 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage Range 90 ~ 264VAC 120~370 Volts(DC) Frequency Range 47-63 Hz Inrush Current, typ: (cold start) 20Amps/115VAC; 40Amps 230VAC Input Current, typ 3.5Amps @115VAC

1.7 Amps @ 230VAC

Leakage current < 2mAmps / 240VAC Min Load See Selection Chart Power Factor @ FL PF> 0.93 / 230VAC 0.98 / 115VAC OUTPUT SPECIFICATIONS Voltage and Current See Selection Chart Line Regulation ±0.5% Load Regulation ±0.1%: 3.3~7.5Volts(DC) ±0.5%: 12~48Volts(DC) Voltage Tolerance (Note 2) ±2.0%: 3.3;15Volts(DC) ±1.0%: 24~48Volts(DC) Ripple/Noise (Note 1) 100mVpk-pk: 3.3~15Volts(DC) 150mVpk-pk: 24;27Volts(DC) 250mVpk-pk: 48Volts(DC) Hold Up Time (typ) 20mS @ FL Setup, Rise Time 600mS, 30mS @ FL Over Voltage Protection See Selection Chart Shut down o/p voltage, re-power Over Current Protection 105 ~ 150% rated output power Constant current limiting,auto recover Over Temperature 95°C ±5°C TSW1: detect on heatsink of power transistor Shut down o/p voltage, auto recover DC Volt Adjust See Selection Chart GENERAL SPECIFICATIONS Safety UL60950-1, TUV EN60950-1 Approved Insulation Resistance ≥ 100MΩ / 500Volts(DC) EMI Compliance to EN55022 (CISPR22) Class B EMS Compliance to ENV50204,EN55024, light Industry Level, Criteria A Harmonic Current Compliance to EN61000-3-2,-3 Efficiency See Selection Chart Isolation 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground ENVIRONMENTAL SPECIFICATIONS Oper. Temperature -10°C to +60°C (See Derate Curve) Storage Temperature -20°C to +85°C, 10~95% RH Relative Humidity 20~90% RH non cond Temperature Coefficient 0.05% / °C (0-50°C) MTBF 183.8KHrs min,MIL-HDBK-217F(25°C) Vibration 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size 199x99 x 50mm (7.83”x3.90 ”x1.97”) Weight 29.99 oz (850g) NOTE 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regula- tion. All specifications are typical at nominal input, full load, and 25°C unless other- wise noted

200W Single Output with PFC Function SP200 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458

200W Single Output with PFC Function SP200 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 3815