SP12 INFINEON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

T Y R E P R E S S U R E S E N S O R WITH ACCELEROMETER S P 1 2 is a piezoresistive pressure sensor and accelerometer designed for tyre pressure measurement applications. The design is based on proven high-volume, low cost production processes developed for products to be used in automotive applications. The SP12 is supplied in a 14 pin SOP (Small Outline Package) plastic package. The sensor design is based upon SensoNor’s proprietary and patented solutions aimed at high reliabilty measurements in harsh environments, still with a predictable and stable quality in high volume applications. The SP12 measures pressure, temperature, supply voltage and radial acceleration, and by integrating these functions with an ASIC in one package, SensoNor has developed the ideal product for tyre pressure monitoring applications, offering the system designer the flexibility to determine sequences and functionality according to his customers demands. F u t u r e T e c h n o l o g y T o d a y . An Infineon Technologies Company Pressure sensor: Range: Temperature sensor: Range: Supply Voltage sensor: Range: Acceleration sensor: Range: S P 1 2 100 to 450kPa -40 to +125°C 1.8 to 3.6V -12 to 115g

Attention please! The information herein is given to describe certain components and shall not be considered as a guarantee of characteristics. Terms of delivery and rights to technical change reserved. We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding circuits descriptions and charts stated herein. Information For further information on technology, delivery terms and conditions and prices please contact SensoNor AS P R O D U C T B R I E F PRESSURE MEASUREMENTS All specification limits to be understood as 4 sigma values. The specified values reflect the situation with an ideal voltage source (0 ohm internal resistance) Input range Resolution Measurement error Measurement time Unit kPa kPa/lsb kPa kPa kPa kPa kPa kPa kPa kPa ms Min 100 -8.5 -20 -10 -25 -17 -30 -25 -40 Typ 1.37 Max 450 8.5 Temperature [° C] -40 to 125 -40 to 125 0 to 50 0 to 50 -20 to 70 -20 to 70 -40 to 100 -40 to 100 100 to 125 100 to 125 Pressure [kPa] 100 - 450 100 - 450 200 - 400 100 - 450 200 - 400 100 - 450 200 - 400 100 - 450 200 - 400 100 - 450 Supply voltage [ V ] 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 SPECIFICATION AMBIENT CONDITIONPARAMETER YYWWXXX ZZZZ NNNNN PACKAGE T YPE 6 How to reach us: Phone: +47 33 03 50 00 Fax: +47 33 03 50 05 www.sensonor.com marketing@sensonor.no Published by SensoNor AS Knudsrødveien 7 P.O.Box 196 N.3192 Horten Norway © SensoNor AS 2003. All Rights Reserved October 2003, 1000 ex. Attention please! The information herein is given to describe certain components and shall not be considered as a guarantee of characteristics. Terms of delivery and rights to technical change reserved. We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding circuits descriptions and charts stated herein. Information For further information on technology, delivery terms and conditions and prices please contact SensoNor AS PARAMETER MIN MAX UNIT ABSOLUTE MAXIMUM RATINGS Prolonged exposure to values between recommended operating conditions and absolute maximum ratings might affect the performance or reliability of the device Input pressure Storage temperature -40 Temperature in application -40 Temperature, transient -40 Supply voltage -0.3 Input voltage, any pin -0.3 Latch-up protection -100 ESD protection (machine model) -200 ESD protection (human body model) -2 Mechanical shock Static acceleration kPa V V mA V kV g g 1400 150 150 175 6.0 VDD + 0.3 100 200 2000 2000 SPECIFICATION AMBIENT CONDITIONPARAMETER SUPPLY VOLTAGE MEASUREMENTS All specification limits to be understood as 4 sigma values Input range Resolution Measurement error Delay time between supply voltage measurement command and sampling Delay time between sampling and A/D conversion Measurement time Unit Min Typ Max Temperature [° C] Supply voltage [ V ] 1.8 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 2.1 - 3.6 -40 to 125 -40 to 125 -40 to 125 -40 to 125 -40 to 125 3.6 0.1 4.2 0.0184 3.5 1.8 -0.1 2.8 V V/lsb V ms ms ms Input range Resolution Deviation from actual temperature Measurement time Unit ° C ° C/lsb ° C ° C ° C ° C ° C ms Min -40 -10 Max 125 1.5 -40 to 125 -40 to 125 0 to 50 -40 to 100 +100 to 125 0 to 50 -40 to 125 Supply voltage [ V ] 2.1 - 3.6 2.1 - 3.6 2.5 - 3.6 2.5 - 3.6 2.5 - 3.6 2.1 - 2.5 2.1 - 2.5 SPECIFICATION AMBIENT CONDITIONPARAMETER TEMPERATURE MEASUREMENTS All specification limits to be understood as 5 sigma values Typ Input range Resolution Sensitivity accuracy Offset Random error (inc. quant. error, noise, repeatability) Measurement time Unit g g/lsb g g g g g ms -12 -18.75 -24 -8.75 -12 Typ 0.5 115 18.75 8.75 -40 to 90 -40 to 90 -40 to 90 90 to 125 -40 to 90 90 to 125 -40 to 90 90 to 125 2.1 to 3.6 2.1 to 3.6 2.1 to 3.6 2.1 to 3.6 2.1 to 3.6 2.1 to 3.6 2.1 to 3.6 SPECIFICATION AMBIENT CONDITIONPARAMETER ACCELEROMETER MEASUREMENTS All specification limits to be understood as 4 sigma values. The specified values reflect the situation with an ideal voltage source (0 ohm internal resistance) Supply voltage [ V ]Temperature [° C]Min Max Temperature [° C]