Features
■ Bidirectional crowbar protection ■ Voltage: range from 140 V to 400 V ■ Low VBO / VR ratio ■ Micro capacitance from 15 pF to 30 pF @ 50 V ■ Low leakage current: IR = 2 µA max ■ Holding current: IH = 150 mA min. ■ Repetitive peak pulse current: IPP = 100 A (10/1000 µs) Benefits ■ Trisils are not subject to ageing and provide a fail safe mode in short circuit for better protection. ■ Helps equipment meet main standards such as UL60950, IEC 950 / CSA C22.2 and UL1459. ■ Epoxy meets UL94, V0. ■ Package is JEDEC registered (DO-214AA). Complies with the following standards ■ GR-1089 Core ■ ITU-T-K20/K21 ■ IEC 61000-4-5 ■ TIA/EIA IS-968 ■ UL497B recognized, UL file E136224
Applications
Any sensitive equipment requiring protection against lightning strikes and power crossing: ■ Terminals (phone, fax, modem...) and central office equipment ■ ADSL2+ and low end VDSL
Description
The SMP100MC is a series of micro capacitance transient surge arrestors designed for the protection of high debit rate communication equipment. Its micro capacitance avoids any distortion of the signal and is compatible with digital transmission line cards (ADSL, VDSL, ISDN...). SMP100MC series has been tested and confirmed compatible with Cooper Bussmann Telecom Circuit Protector TCP 1.25 A. TM: Trisil is a trademark of STMicroelectronics. SMB (JEDEC DO-214AA)
1 Characteristics
Table 1. In compliance with the following standards
Figure 1. Electrical charac teristics - definitions (Tamb = 25 °C) Table 2. Absolute ratings (T amb = 25 °C)
- In fail safe mode the devic e acts as a short circuit.
21 A²s
Table 3. Thermal resistances
Table 4. Electrical characteristics - values (T amb = 25 °C)
- See Figure 16: Test circuit 1 for Dynamic IBO and VBO parameters
- See Figure 17: Test circuit 2 for IBO and VBO parameters
- See Figure 18: Test circuit 3 for dynamic IH parameter
- V R = 2 V bias, VRMS=1V, F=1 MHz
2 Application information
Figure 10. Examples of protection stages for line cards Figure 8. Variation of thermal impedance Figure 9. Relative variation of junction
Figure 14. Trisil action while the fuse remains operational Figure 15. High current power cross test: the fuse acts like a switch by opening the
277 V 25 A (second level), Tamb = 25 °C
Fuse safety opened and Trisil OK after test in accordance with GR1089 requirements.
Figure 16. Test circuit 1 for Dynamic I BO and VBO parameters Figure 17. Test circuit 2 for I BO and VBO parameters
100 V / µs, di/dt < 10 A / µs, Ipp = 100 A
Figure 18. Test circuit 3 for dynamic I H parameter
3 Ordering information scheme
Figure 19. Ordering information scheme 1/ Adjust the current level at the I value by short circuiting the AK of the D.U.T. 3/ The D.U.T. will come back off-state within 50 ms maximum.
4 Package information
- Epoxy meets UL94, V0
- Lead-free package In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark.
Table 5. SMB dimensions Figure 20. Footprint dimensions Figure 21. Marking layout (1)
- Marking layout can vary according to assembly location.
5 Ordering information
6 Revision history
Table 6. Ordering information Table 7. Document revision history September-2003 0B First issue. 14-Dec-2004 1 Absolute ratings values, table 3 on page 2, updated. 11-May-2005 2 New types introduction. 09-Feb-2012 5 Added UL statement in Complies with the following standards.