SMP100LC_07 STMICROELECTRONICS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 12

Technical content

Features

■ Bidirectional crowbar protection ■ Voltage range from 8 V to 400 V ■ Low capacitance from 20 pF to 45 pF @ 50 V ■ Low leakage current : IR = 2 µA max ■ Holding current: IH = 150 mA min ■ Repetitive peak pulse current: IPP = 100 A (10/1000 µs) Main applications Any sensitive equipment requiring protection against lightning strikes and AC power faults. These devices are dedicated to central office protection as they comply with the most stressfull standards. Their Low Capacitances make them suitable for xDSL.

Description

The SMP100LC is a series of low capacitance transient surge arrestors designed for the protection of high data rate communication equipment. Its low capacitance avoids any distortion of the signal and is compatible with digital transmission line cards (xDSL, ISDN...). SMP100LC series tested and confirmed compatible with Cooper Bussmann Telecom Circuit Protector TCP 1.25A. The SMP100LC-xxx with the fuse TCP1.25A or TCP2A is compliant with Telcordia GR1089 (lightning and AC power fault tests), ITU-T K20/K21 (lightning and AC power fault tests), TIA/EIA-IS-968 (formely FCC Part 68 lightning tests), UL60950 (AC power fault tests). Moreover, the use of the TCP1.25A allows the SMP100LC-xxx to be safe for the 2nd level (B criteria) AC power fault tests. Order Code Benefits Trisils are not subject to ageing and provide a fail safe mode in short circuit for a better protection. They are used to help equipment to meet main standards such as UL60950, IEC950 / CSA C22.2 and UL1459. They have UL94 V0 approved resin. SMB package is JEDEC registered (DO-214AA). Trisils comply with the following standards GR-1089 Core, ITU-T -K20/K21, VDE0433, VDE0878, IEC61000-4-5 and FCC part 68. Order code Marking SMP100LC-xxx See Section 5 on page 11 SMB (JEDEC DO-214AA)

1 Characteristics

Table 1. Compliant with the following standards Table 2. Absolute ratings (T amb = 25° C)

  1. in fail safe mode, the dev ice acts as a short circuit

21 A2s

Table 3. Thermal Resistances Table 4. Electrical Characteristics (Tamb = 25° C)

  1. I R measured at VR guarantee VBR min ≥ VR
  2. See Figure 15: Test circuit 1 for Dynamic IBO and VBO parameters
  3. See Figure 16: Test circuit 2 for IBO and VBO parameters
  4. See Figure 17: Test circuit 3 for dynamic IH parameter

2 Application information

protected. This function is assumed by a combined series / parallel protection stage. Figure 9. Examples of protection stages for line cards mains disturbance surges are defined by standards like GR1089, FCC part 68, ITU-T K20. Figure 10. Typical circuits Figure 7. Variation of thermal impedance Figure 8. Relative variation of junction

Figure 13. Trisil action while fuse remains operational Fuse and Trisil OK after test in accordance with GR1089 requirements. Figure 14. High current AC power test: the fuse acts like a switch by opening the

277 V, 25 A (second level), Tamb = 25° C

Fuse safely opened and Trisil OK after test in accordance with GR1089 requirements.

Figure 15. Test circuit 1 for Dynamic I BO and VBO parameters Figure 16. Test circuit 2 for I BO and VBO parameters

100 V / µs, di/dt < 10 A / µs, Ipp = 100 A

Figure 17. Test circuit 3 for dynamic I H parameter

3 Ordering information scheme

1/ Adjust the current level at the I value by short circuiting the AK of the D.U.T. 3/ The D.U.T. will come back off-state within 50ms maximum.

4 Package information

Figure 18. Footprint (dimensions in mm) Table 5. SMB Dimensions

5 Ordering information

6 Revision history

Part Number Marking Package Weight Base qty Delivery mode SMP100LC-8 PL8 SMB 0.11 g 2500 Tape & reel SMP100LC-25 L25 SMP100LC-35 L35 SMP100LC-65 L06 SMP100LC-90 L09 SMP100LC-120 L12 SMP100LC-140 L14 SMP100LC-160 L16 SMP100LC-200 L20 SMP100LC-230 L23 SMP100LC-270 L27 SMP100LC-320 L32 SMP100LC-360 L36 SMP100LC-400 L40 Date Revision Changes 09-Nov-2004 9 Absolute ratings values, table 3 on page 2, updated. 07-Dec-2004 10 SMP100LC-320, SMP100L C-360 and SMP100LC-400 addition. 20-Jun-2005 11 Telecom Circuit Protector added in Description. 05-Mar-2007 12 Reformatted to current standards. SMB Package information updated. Standards compliance paragraphs added to Description