LG1 MACOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
North America: 1-800-366-2266 Visit www.macom.com for complete contact and product information. LG1 / SMLG1 TO-8 THIN-FILM LINEARIZER
- WIDE TEMPERATURE OPERATION
- YIELDS LINEAR ATTENUATION (dB) FOR LINEAR CONTROL VOLTAGE Linearity Specifications (Rev. Date: 3/02)* Temperature Typical Guaranteed Max. -54°C to +85°C < ±1.5 dB ±2.0 dB * Frequency: 10-1000 MHz; attenuation range: 3 to 20 dB Typical Current Drain Control Voltage = -10 V (Min. Attenuation) Control Voltage = 0 V (Max. Attenuation) -V 5 mA 5 mA +V 24 mA 11 mA Vcon 15 mA 2.5 mA Combination of LGI and GI -V 5 mA 5 mA +V 31 mA 21 mA Vcon 15 mA 2.5 mA Absolute Maximum Ratings Storage Temperature -62°C to +125°C Max. Case Temperature 125°C Max. DC Voltage +17 Volts “S” Series Burn-in Temperature (Case) 125°C Outline Drawings Package TO-8 Surface Mount SMA Connectorized Figure BJ AD CG Model LG1 SMLG1 CLG1 Typical Performance @ 25°C M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.