cui.com date 01/27/2016 page 1 of 5 SERIES: SMI24 │ DESCRIPTION: AC-DC POWER SUPPLY MODEL output voltage output current output power ripple and noise1 efficiency level (Vdc) max (A) max (W) max (mVp-p) SMI24-5 5 4 20 100 VI SMI24-9 9 2.5 22.5 100 VI SMI24-12 12 2 24 120 VI SMI24-15 15 1.6 24 150 VI SMI24-24 24 1 24 240 VI SMI24-48 48 0.5 24 480 VI Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 μF multilayer ceramic and 10 μF low ESR electrolytic capacitors.
FEATURES
- up to 24 W continuous power
- DOE Level VI, CEC, ErP Stage 2
- no load power consumption < 0.1 W
- universal input voltage range
- interchangeable Ac blades for global use
- over voltage, over current, and short circuit protections
- UL/cUL, RCM, CCC, and PSE safety approvals PART NUMBER KEY Base Number Reserved for Custom Configurations SMI24 - XX - X - XXX - CXX DC Plug Type: XXX = See output plug options on page 4 for more details ST = Stripped and Tinned Output Voltage Blades: V = North America, Europe, United Kingdom, Australia, and China blade included N = North America blade included E = Europe blade included B = United Kingdom blade included A = Australia blade included C = China blade included K = No blades included For more information, please visit the product page | For information on related products, view Dc Power Jacks
cui.com date 01/27/2016 │ page 2 of 5CUI Inc │ SERIES: SMI24 │ DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description min typ max units voltage 90 264 Vac frequency 47 63 Hz current 0.58 A inrush current at 100 Vac, full load, 25°C, cold start at 230 Vac, full load, 25°C, cold start A A leakage current 0.25 mA no load power consumption at 230 Vac 0.1 W OUTPUT parameter conditions/description min typ max units regulation 5 Vdc output model all other models hold-up time at full load 10 ms PROTECTIONS parameter conditions/description min typ max units over voltage protection output shut down
5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
48 Vdc output model
output shut down, auto recovery 2.5 1.2 A A A A A A short circuit protection output shut down, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output at 10 mA for 1 minute 3,000 Vac isolation resistance input to output at 500 Vdc 10 MΩ safety approvals UL/cUL, RCM, CCC, PSE EMI/EMC FCC Part 15B Class B, CE MTBF as per Telcordia SR-332, 25°C 300,000 hours RoHS 2011/65/EU ENVIRONMENTAL parameter conditions/description min typ max units operating temperature 0 40 °C storage temperature -20 80 °C operating humidity non-condensing 20 80 % storage humidity non-condensing 10 90 % For more information, please visit the product page | For information on related products, view Dc Power Jacks
cui.com date 01/27/2016 │ page 3 of 5CUI Inc │ SERIES: SMI24 │ DESCRIPTION: AC-DC POWER SUPPLY DC CORD MODEL NO. CABLE CORD LENGTH SMI24-5 UL2468, 18 AWG 1,000 mm ±30 SMI24-9 UL2468, 18 AWG 1,500 mm ±30 SMI24-12 UL2468, 20 AWG 1,500 mm ±30 SMI24-15 UL2468, 20 AWG 1,500 mm ±30 SMI24-24 UL2468, 22 AWG 1,500 mm ±30 SMI24-48 UL2468, 22 AWG 1,500 mm ±30 units: mm Table 1 MECHANICAL parameter conditions/description min typ max units dimensions 75 x 35.8 x 65.6 mm inlet plug interchangeable blades (North America, Europe, UK, Australia, China) weight without blades 170 g MECHANICAL DRAWING units: mm tolerance: ±0.5 mm INTERCHANGEABLE BLADES BLADE DESIGNATOR N E B A C REGION North America Europe UK Australia China BLADE ACCESSORY SMI-US-2 SMI-EU-2 SMI-UK-2 SMI-AU-2 SMI-CN-2 BLADE For more information, please visit the product page | For information on related products, view Dc Power Jacks
cui.com date 01/27/2016 │ page 4 of 5CUI Inc │ SERIES: SMI24 │ DESCRIPTION: AC-DC POWER SUPPLY OUTPUT PLUG OPTIONS Stripped and Tinned A C B A B C C A B Right Angle PlugStraight Plug Locking DC Plug Standard DC Plug DC Plug Type 25±5 5±5 10±2 C A B C A B EIAJ DC Plug Right Angle PlugStraight Plug Size A B C Unit 5 5.5 2.1 9.5 mm 6 5.5 2.5 9.5 mm 7 3.5 1.35 9.5 mm 8 3.8 1.35 9.5 mm 9 3.8 1.05 9.5 mm X X X Plug Size: X = See above plug options Plug Angle: “blank” = Straight R = Right Angle *Contact CUI for additional plug options Plug Polarity: P = Center Positive N = Center Negative Size A B C Unit 10 5.5 2.1 9.5 mm 11 5.5 2.5 9.5 mm Size EIAJ A B C Unit 12 EIAJ-1 2.35 0.7 9.5 mm 13 EIAJ-2 4.0 1.7 9.5 mm 14 EIAJ-3 4.75 1.7 9.5 mm For more information, please visit the product page | For information on related products, view Dc Power Jacks
date 01/27/2016 │ page 5 of 5CUI Inc │ SERIES: SMI24 │ DESCRIPTION: AC-DC POWER SUPPLY This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 08/07/2015 1.01 updated datasheet 11/04/2015 1.02 housing width changed to 35.8 mm 01/27/2016 The revision history provided is for informational purposes only and is believed to be accurate.