102V88F SKELETON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Rated maximum peak current (for 1 s duration) 1, 9 Typical short circuit current (For informational purposes - do not use as operating current.) Maximum stored energy 2 Cells in total Cell type International protection marking (for enclosure) Isolation protection EMC immunity EMC emissions Operating temperature range* Minimum Maximum Storage temperature range (uncharged) Minimum Maximum Storage life @ RT, uncharged Projected cycle life @ RT, between VR and VR / 2 Life Lifetime @ 102V and maximum operating temperature + 102V DC nominal voltage + Ultra-low ESR + Integrated Supercapacitor Management System for effective cell balancing + Long lifetime - 1 million duty cycles + CAN bus communication + 19 inch rack system compatible General Specifications Standards and certifications DATA SHEET Temperature and LifeValue ValueUnit Unit V V F mΩ mΩ Wh/kg Wh/L VDC kA kA Wh pcs 6730083 102 108 6.2 7.6 4.8 4.3 1500* 2.69 21.25 127.1 SCA3200 IEC 60529, IP 20 IEC 62477-1, OVC2, PD2 IEC 61000-6-2 IEC 61000-6-3 Years Cycles Hours -20 +60 -40 +50 1,000,000 1500 Copyright © 2022 Skeleton Technologies GmbH. All rights reserved. 01-DS-211228-SKELMOD-102V88F-1D Page 1/2 SkelMod 102V88F Rated nominal power, calculated from 10 ms ESR Power 6 Specific power, matched Impedance 7 Power density, matched Impedance 4 Rated practical power, calculated from 1 s ESR Power 6 Specific power, matched Impedance 7 Power density, matched impedance 4 Power kW kW/kg kW/L kW kW/kg kW/L 419.5 15.8 14.2 342.2 12.9 11.6

Copyright © 2022 Skeleton Technologies GmbH. All rights reserved. 01-DS-211228-SKELMOD-102V88F-1D Page 2/2 Nominal auxiliary supply voltage Auxiliary supply voltage range Constant current consumption at 24V DC Cell balancing method Temperature monitor Voltage monitor Communication interface Mass. Typical Volume Thermal resistance given at ΔT 30 °C (Rth) Thermal capacitance (Cth) Max continuous current 10, ΔT = 15°C Max continuous current 10, ΔT = 30°C Max continuous current 10, ΔT = 40°C Thermal* Value Value Value Unit Unit Unit V V A kg L °C/W kJ/°C A A A 16-33 0-07 Controlled resistive balancing

6 NTC sensors

CAN bus 2.0B 26.5 29.6 0.065 174 246 285 Supercapacitor management system Physical parameters 480 465 24.7 76.9 24.7 13.1 4 450 501.5 152.5 76.25 31.5 13.5 THRU 424 449 486 21.75 480 253

2 X 9 THRU

Ø 13.5 mm Trough hole D-sub DE-9 Male D-sub DE-9 Female Front + Name of manufacturer, part number, serial number, rated voltage + Rated capacitance, negative and positive terminals, warning marking + Total energy in watt-hours (9) The stated maximum peak current should not be exceeded during use. If the limit is to be exceeded by the customer, Skeleton must be consulted beforehand and give approval for the exceeded power load. * For maximum series voltage IE32 (EN 60721-3-3) requirements must be followed. For lower temperature contact Skeleton Technologies Inrush current for the auxiliary supply: 0.18A * Thermal parameters given for cooling airflow rate of 85CFM Standard markings + All information provided on this data sheet and all subsequent supercapacitors sales and testing are subject to Standard Terms of Service (ToS) available on www.skeletontech.com, document General Terms of Sale for Skeleton Technologies GmbH Notes (10) These values of current refer to begin of life conditions of the product, for system design 200% ESR should be considered.