Catalog Safety Supply Maximum Type Model Page Category Resolution Voltage Range SAFETY LIGHT SCREEN SELECTION EZ-SCREEN ® Standard Systems Page 20 4 14 & 30 mm 24V dc 18 m Cascade Systems 14 & 30 mm 18 m Grid & Point Systems 300 to 584 mm (beam spacing) 70 m PICO-GUARD ™ Grid Systems Page 36 4 300 to 584 mm (beam spacing) 24V dc 31 m Point Systems — MICRO-SCREEN ® Emitters & Receivers Page 42 4 19 mm Supplied by controller 9 m Standard Series 32 mmV-Series Controllers N/A 24V dc, 115 or 230V ac N/A Metal Box Controllers 24V dcDIN Module Controllers MINI-SCREEN ® Emitters & Receivers Page 58 4 19 & 25 mm Supplied by controller 18 m Standard Series 38 mmHeavy-Duty Series Controllers N/A 24V dc, 115V ac or 230V ac N/A Metal Box Controllers 24V dcDIN Module Controllers EZ-SCREEN ® Type 2 Type 2 Systems Page 78 2 30 mm 24V dc 15 m NC = Normally Closed Relay, NO = Normally Open Relay
Safety Muting Output Housing Environmental Output Blanking Option Response Time Material Rating
2 PNP
(Trip /Latch Selectable) Reduced Resolution (floating) 2-beam Fixed Optional Accessory (see page 123) 9 to 56 ms Aluminum housing with yellow polyester powder finish or nickel-plated ESD IEC IP6511 to 56 ms — ≤ 24 ms (Trip /Latch Selectable) See page 108 for controller Optional Accessory (see page 123) 13 ms See page 108 for controller Black aluminum housing, tempered glass window IEC IP65 12 mm threaded barrel: Black polycarbonate plastic housing 30 mm threaded barrel: Stainless steel housing, glass window. IEC IP67 Reduced Resolution (floating) 1- or 2-beam Fixed < 38 ms (< 48 ms for muting) Aluminum housing with yellow polyester powder finish or nickel-plated ESD IEC IP65 2 NO (Trip or Latch) Yes Welded steel box with black polyester powder paint finish IEC IP64 2 or 4 NO (Trip or Latch) Optional Accessory (see page 123) Gray polycarbonate IEC IP20 Reduced Resolution (floating) 1- or 2-beam Fixed < 48 to < 72 ms (< 58 to < 82 ms for muting) Aluminum housing with black anodized or yellow polyester painted finish IEC IP65 2 NO (Trip or Latch) Yes Welded steel box with black polyester powder paint finish IEC IP64 Optional Accessory (see page 123) Gray polycarbonate IEC IP20 (Trip or Latch) Optional Accessory (see page 123) 11 to 25 ms Aluminum housing with yellow polyester powder finish IEC IP65
MICRO-SCREEN® MINI-SCREEN SAFETY LIGHT SCREENS EZ-SCREEN® TYPE 2 EZ-SCREEN Systems SAFETY LIGHT SCREENS EZ-SCREEN Safety Light Screens Simple, two-piece integrated system has no control box. High-resolution 14 and 30 mm EZ-SCREEN® point-of-operation systems provide finger, hand and ankle detection. EZ-SCREEN Point and Grid systems allow one-, two-, three- or four-beam perimeter and access guarding. Superior optical design and finely focused ±2.5° beam make systems extremely easy to align and maintain. Status indicators and diagnostics show when alignment is complete and if there are problems with the installation. Redundant microprocessor-controlled, self-checking design exceeds control reliability requirements and is certified per CE (Type 4/Category 4) and cULus (NIPF, UL 61496, UL 1998). Unique cascading models (patent-pending) allow up to four systems of any length and resolution to be wired together to form a single safety device. Systems have ranges up to 70 m, with power and range for all types of applications including long-range perimeter guarding. Point of operation. Finger, hand or ankle detection at the point of operation. Use 14 or 30 mm EZ-SCREEN. Area. Mount horizontally to eliminate safety mats and area scanners. Manually reset Latch output when area is clear. Perimeter. Guard mulitple sides of a dangerous area up to 70 m long. Expand guarding with optional corner mirrors and mounting stands. Long-range single sided. EZ-SCREEN Grid systems provide 2, 3 or 4 beams. Beam spacing is from 300 to 584 mm. Single point access. Use with angled mirrors to simulate a 2-beam system. Use multiple units for custom beam patterns. ESD applications. Dissipate electrostatic discharges. Ideal for microelectronic applications. A complete family of machine guarding products. QD CABLES PAGE 176 ).$)#!4/23 PAGE 187 -)22/23 PAGE 204 34!.$3 PAGE 209 ,%.33()%,$3 PAGE 213 %.#,/352%3 PAGE 216 8-Pin Euro + 3- & 8-Pin Mini BRACKETS PAGE 190
MINI-SCREEN® SAFETY LIGHT SCREENS EZ-SCREEN TYPE 2 EZ-SCREEN Systems, 14 mm Resolution Models* Resolution Range Defined Area Housing Length (L) Supply Voltage Safety Outputs Response Time Connec- tion Data Sheet SLSP14-150Q88 † 14 mm Resolution 0.1 to 6 m 150 mm 262 mm 24V dc 2 PNP OSSD ≤ 11 ms 8-pin Euro QD 112852 SLSE14-150Q8 SLSR14-150Q8 SLSP14-300Q88 300 mm 372 mm ≤ 15 msSLSE14-300Q8 SLSR14-300Q8 SLSP14-450Q88 450 mm 522 mm ≤ 19 msSLSE14-450Q8 SLSR14-450Q8 SLSP14-600Q88 600 mm 671 mm ≤ 23 msSLSE14-600Q8 SLSR14-600Q8 SLSP14-750Q88 750 mm 821 mm ≤ 27 msSLSE14-750Q8 SLSR14-750Q8 SLSP14-900Q88 † 900 mm 971 mm ≤ 32 msSLSE14-900Q8 SLSR14-900Q8 SLSP14-1050Q88 1050 mm 1120 mm ≤ 36 msSLSE14-1050Q8 SLSR14-1050Q8 7-segment diagnostic display Blocked beam zone indicators System status and system reset status Integral or pigtail Euro-style QD connection Durable aluminum housing to resist twisting Metal end caps for added durability User configurable trip or latch outputs and Scan Code 1 or 2 Fixed or 2-beam reduced resolution (floating) blanking EDM input and optional TEST function EZ-SCREEN® Systems EZ-SCREEN Systems 45.0 mm L 36.0 mm Full View of Available Finishes Yellow Painted Aluminum Nickel-Plated ESD 14 mm Resolution * Nickel-plated emitters and receivers used for ESD safe applications are available by adding “N” in the model number (example, SLSE14-150NQ8 ). ** For an emitter with TEST function, replace Q8 with Q5 on emitter model numbers (example, SLSE14-150Q5 ) and Q88 with Q85 on pair model numbers (example, SLSP14-150Q85 ). For a 300 mm Euro pigtail QD, replace “Q” with “P” in models numbers (example, SLSP14-150P88 ). A model with a QD requires a mating cable (see page 176). A pair includes an emitter and receiver (example, SLSP14-150Q88 ). Emitters (example, SLSE14-150Q8 ) and receivers (example, SLSR14-150Q8 ) are also sold separately.
MICRO-SCREEN® MINI-SCREEN SAFETY LIGHT SCREENS EZ-SCREEN® TYPE 2 EZ-SCREEN Systems, 14 mm Resolution Models* Resolution Range Defined Area Housing Length (L) Supply Voltage Safety Outputs Response Time Connec- tion** Data Sheet SLSP14-1200Q88 † 14 mm Resolution 0.1 to 6 m 1200 mm 1270 mm 24V dc 2 PNP OSSD ≤ 40 ms 8-pin Euro QD 112852 SLSE14-1200Q8 SLSR14-1200Q8 SLSP14-1350Q88 1350 mm 1420 mm ≤ 43 msSLSE14-1350Q8 SLSR14-1350Q8 SLSP14-1500Q88 1500 mm 1569 mm ≤ 48 msSLSE14-1500Q8 SLSR14-1500Q8 SLSP14-1650Q88 1650 mm 1719 mm ≤ 52 msSLSE14-1650Q8 SLSR14-1650Q8 SLSP14-1800Q88 1800 mm 1869 mm ≤ 56 msSLSE14-1800Q8 SLSR14-1800Q8 EZ-SCREEN Systems, 30 mm Resolution Models* Resolution Range Defined Area Housing Length (L) Supply Voltage Safety Outputs Response Time Connec- tion** Data Sheet SLSP30-150Q88 30 mm Resolution 0.1 to 18 m 150 mm 262 mm 24V dc 2 PNP OSSD ≤ 9 ms 8-pin Euro QD 112852 SLSE30-150Q8 SLSR30-150Q8 SLSP30-300Q88 300 mm 372 mm ≤ 11 msSLSE30-300Q8 SLSR30-300Q8 SLSP30-450Q88 † 450 mm 522 mm ≤ 13 msSLSE30-450Q8 SLSR30-450Q8 SLSP30-600Q88 600 mm 671 mm ≤ 15 msSLSE30-600Q8 SLSR30-600Q8 SLSP30-750Q88 750 mm 821 mm ≤ 17 msSLSE30-750Q8 SLSR30-750Q8 14 mm Resolution 30 mm Resolution * Nickel-plated emitters and receivers used for ESD safe applications are available by adding “N” in the model number (example, SLSE14-1200NQ8 ). ** For an emitter with TEST function, replace Q8 with Q5 on emitter model numbers (example, SLSE14-1200Q5 ) and Q88 with Q85 on pair model numbers (example, SLSP14-1200Q85 ). For a 300 mm Euro pigtail QD, replace “Q” with “P” in models numbers (example, SLSP14-1200P88 ). A model with a QD requires a mating cable (see page 176). A pair includes an emitter and receiver (example, SLSP14-1200Q88). Emitters (example, SLSE14-1200Q8) and receivers (example, SLSR14-1200Q8) are also sold separately. (cont’d)
MINI-SCREEN® SAFETY LIGHT SCREENS EZ-SCREEN TYPE 2 EZ-SCREEN Systems, 30 mm Resolution Models* Resolution Range Defined Area Housing Length (L) Supply Voltage Safety Outputs Response Time Connec- tion** Data Sheet SLSP30-900Q88 † 30 mm Resolution 0.1 to 18 m 900 mm 971 mm 24V dc 2 PNP OSSD ≤ 19 ms 8-pin Euro QD 112852 SLSE30-900Q8 SLSR30-900Q8 SLSP30-1050Q88 1050 mm 1120 mm ≤ 21 msSLSE30-1050Q8 SLSR30-1050Q8 SLSP30-1200Q88 1200 mm 1270 mm ≤ 23 msSLSE30-1200Q8 SLSR30-1200Q8 SLSP30-1350Q88 1350 mm 1420 mm ≤ 25 msSLSE30-1350Q8 SLSR30-1350Q8 SLSP30-1500Q88 1500 mm 1569 mm ≤ 27 msSLSE30-1500Q8 SLSR30-1500Q8 SLSP30-1650Q88 1650 mm 1719 mm ≤ 30 msSLSE30-1650Q8 SLSR30-1650Q8 SLSP30-1800Q88 1800 mm 1869 mm ≤ 32 msSLSE30-1800Q8 SLSR30-1800Q8 30 mm Resolution * Nickel-plated emitters and receivers used for ESD safe applications are available by adding “N” in the model number (example, SLSE30-900NQ8 ). ** For an emitter with TEST function, replace Q8 with Q5 on emitter model numbers (example, SLSE30-900Q5 ) and Q88 with Q85 on pair model numbers (example, SLSP30-900Q85 ). For a 300 mm Euro pigtail QD, replace “Q” with “P” in models numbers (example, SLSP30-900P88 ). A model with a QD requires a mating cable (see page 176). A pair includes an emitter and receiver (example, SLSP30-900Q88 ). Emitters (example, SLSE30-900Q8 ) and receivers (example, SLSR14-900Q8 ) are also sold separately. (cont’d)
MINI-SCREEN® SAFETY LIGHT SCREENS EZ-SCREEN TYPE 2 EZ-SCREEN® 14 & 30 mm Resolution Specifications Supply Voltage at the Device* 24V dc ±15% (SELV), ± 10% max. ripple Supply Current Emitter: 100 mA max. Receiver: 275 mA max., exclusive of OSSD1 and OSSD2 loads (up to an additional 0.5A each) Response Time 9 to 56 millesconds Cascade Safety Stop Interface (CSSI): 40 milliseconds max. Remote Test Input (Optional – available only on model SLSE..-..Q5 emitters) Test Mode is activated either by applying a low signal (less than 3V dc) to emitter TEST #1 terminal for a minimum of 50 milliseconds, or by opening a switch connected between TEST #1 and TEST #2 for a minimum of 50 milliseconds. Beam scanning stops to simulate a blocked condition. A high signal at TEST #1 deactivates Test Mode. (See p/n 112852 for more information.) High signal: 10 to 30V dc Low signal: 0 to 3V dc Input current: 35 mA inrush, 10 mA max. Wavelength of Emitter Elements Infrared LEDs, 950 nm at peak emission EDM Input +24V dc signals from external device contacts can be monitored (one-channel, two-channel or no monitoring) via EDM1 and EDM2 terminals in the receiver. Monitored devices must respond within 200 milliseconds of an output change. High signal: 10 to 30V dc at 30 mA typical Low signal: 0 to 3V dc Dropout time: 200 milliseconds max. Reset Input The Reset input must be high for 0.25 to 2 seconds and then low to reset the receiver. High signal: 10 to 30V dc at 30 mA typical Low signal: 0 to 3V dc Closed switch time: 0.25 to 2 seconds Safety Outputs Two redundant solid-state 24V dc, 0.5 A max. sourcing OSSD (Output Signal Switching Device) safety outputs. (Use optional interface modules for ac or larger dc loads.) Capable of the Banner “Safety Handshake”. ON-State voltage: ≥ Vin-1.5V dc OFF-State voltage: 1.2V dc max. (0-1.2V dc) Max. load capacitance: 1.0 µF Max. load inductance: 10 H Leakage current: 0.50 mA maximum Cable resistance: 10 Ω maximum OSSD test pulse width: 100 to 300 microseconds OSSD test pulse period: 5 to 27 milliseconds (varies with number of beams) Switching current: 0-0.5 A Controls and Adjustments Emitter: Scan Code selection: 2-position switch (code 1 or 2). Factory default position is code 1. Receiver: Scan Code selection: 2-position switch (code 1 or 2). Factory default position is code 1. Trip/Latch Output selection: Redundant switches. Factory default position is T (Trip). EDM/MPCE monitor selection: 2-position switch selects between 1- or 2-channel monitoring. Factory default position is 2. Reduced Resolution (2-beam Floating Blanking): Redundant switches to enable. Factory default is OFF. Short Circuit Protection All inputs and outputs are protected from short circuits to +24V dc or dc common* Electrical Safety Class (IEC 61140: 1997) III Safety Rating Type 4 per IEC 61496-1, -2; Category 4 per ISO 13849-1 (EN 954-1) Operating Range 14 mm models: 0.1 m to 6 m 30 mm models: 0.1 m to 18 m Range decreases with use of mirrors and/or lens shields: Lens shields – approximately 10% less range per shield. Glass-surface mirrors – approximately 8% less range per mirror. See Accessory section for more information on a specific mirror, page 204. Ambient Light Immunity > 10,000 lux at 5° angle of incidence Effective Aperture Angle (EAA) Meets Type 4 requirements per IEC 61496-2, ± 2.5° @ 3 m *The external voltage supply must be capable of buffering brief mains interruptions of 20 milliseconds, as specified in IEC/EN 60204-1.
MICRO-SCREEN® MINI-SCREEN SAFETY LIGHT SCREENS EZ-SCREEN® TYPE 2 EZ-SCREEN 14 & 30 mm Resolution Specifications Enclosure Materials: Extruded aluminum housing with yellow polyester powder or nickel-plated finish and well-sealed, rugged die-cast zinc end caps, acrylic lens cover, copolyester access cover Rating: IEC IP65 Operating Conditions Temperature: 0° to +55° C Relative humidity: 95% (non-condensing) Status Indicators Emitter: One Bi-color (Red/Green) Status Indicator – indicates operating mode, Lockout or power OFF condition 7-segment Diagnostic Indicator (1 digit) – indicates proper operation, scan code or error code Receiver: Yellow Reset Indicator – indicates whether system is ready for operation or requires a reset Bi-Color (Red/Green) Status Indicator – indicates general system and output status Bi-Color (Red/Green) Zone Status Indicators – indicates condition (clear or blocked beam) of a defined group of beams 7-Segment Diagnostic Indicator (3-digit) – indicates proper operation, scan code or error code, total number of blocked beams Mounting Hardware Emitter and receiver each are supplied with a pair of swivel end-mounting brackets. Models longer than 900 mm also include a swivel center-mount bracket. Mounting brackets are 8-gauge cold-rolled steel, black zinc finish. Shock and Vibration EZ-SCREEN systems have passed vibration and shock tests according to IEC 61496-1. This includes vibration (10 cycles) of 10-55 Hz at 0.35 mm single amplitude (0.70 mm peak-to-peak) and shock of 10 g for 16 milliseconds (6,000 cycles). Certifications For a list of certifications see page 236. Wiring Diagrams WD001, WD002, WD003, WD004, WD009, WD010, WD011, WD012, WD013, WD014, WD015, WD016 (pp. 246-254) EZ-SCREEN 14 & 30 mm Resolution Specifications (cont’d)