Product specification – August 12, 2024 V.2 DATA SHEET CEMENT RESISTORS Low Ohmic, Metal Plate Vertical Mount SLR Series ±5%, ±10% 2W to 10W RoHS compliant & Halogen Free
www.yageo.com Aug. 12, 2024 V.2 Cement Resistors 2 8 Product Specification SLR Through Hole Resistors
APPLICATIONS
Home appliance Consumer
FEATURES
Ultra miniature size Current detecting resistors Flameproof cement case RoHS compliant and halogen free
ORDERING INFORMATION
Part number of the cement resistor is identified by the series, power rating, tolerance, packing, temperature coefficient, resistance value and type code. PART NUMBER SLR 500 J B - 0R035 U (1) SERIES SLR Series (2) POWER RATING 200 = 2W 300 = 3W 500 = 5W 700 = 7W 10A = 10W (3) TOLERANCE J = ±5% K = ±10% (4) PACKAGING B = Bulk (5) TEMPERATURE COEFFICIENT OF RESISTANCE - = Based on spec. (6) RESISTANCE VALUE Example: 0R035 = 0.035Ω, 0R1 = 0.1Ω, 1R = 1Ω (7) TYPE CODE Optional code for different type. . Example: Null = Standard type E = SLR200 & SLR300 / ψd=0.8±0.05mm copper wire U = SLR500 & SLR700 & SLR10A / ψd=0.6±0.05mm copper wire C = SLR200 & SLR300 / ψd=0.8±0.05mm CP- wire W = SLR500 & SLR700 & SLR10A / ψd=0.6±0.05mm CP- wire
www.yageo.com Aug. 12, 2024 V.2 Cement Resistors 3 8 Product Specification SLR Through Hole Resistors DIMENSIONS Unit: mm Normal A B C D ψd RM SLR200 8±1 13±1 3.5±1 5±1 0.60±0.05 9±1 SLR300 13±1 13±1 3.5±1 5±1 0.60±0.05 9±1 SLR500 18±1 14±1 3.5±1 5±1 0.80±0.05 10±1 SLR700 18±1 26±1 3.5±1 5±1 0.80±0.05 20±1 SLR10A 20±1 26±1 3.5±1 5±1 0.80±0.05 20±1 DERATING CURVE SLR200 Rated Power (%)1008060402070 155 275 Ambient Temperature (°C)58 SLR300 ~ SLR10A Rated Power (%)1008060402040 155 275 Ambient Temperature (°C)51
www.yageo.com Aug. 12, 2024 V.2 Cement Resistors 4 8 Product Specification SLR Through Hole Resistors TEMPERATURE CURVE
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS SLR200 SLR300 SLR500 SLR700 SLR10A Power Rating at 70 °C 2W Power Rating at 40 °C 3W 5W 7W 10W Voltage Proof on Insulation 500V 700V 700V 1000V 1000V Resistance Range 0.01Ω ~ 0.5Ω 0.005Ω ~ 0.005Ω ~ 0.005Ω ~ 0.009Ω ~ Maximum Working Voltage √(P X R) Operating Temp. Range - 55°C to +155°C Temperature Coefficient ±250ppm/°C Note: For resistance value out of above range is by request. TABLE I MATERIALS OF LEAD WIRE TYPE Resistance Value SLR Series ≤0.05Ω ˃0.05Ω Copper Wire CP Wire
www.yageo.com Aug. 12, 2024 V.2 Cement Resistors 5 8 Product Specification SLR Through Hole Resistors TEST AND REQUIRMENTS TEST TEST METHOD PROCEDURE APPRAISE Short Time Overload IEC 60115-1 4.13 2.5 times RCWV for 5 sec.(Not more than maximum overload voltage) ±2.0%+0.05Ω Voltage Proof on Insulation IEC 60115-1 4.7 In V-Block for 60 sec. test voltage as above table No Breakdown Temperature Coefficient IEC 60115-1 4.8 Between -55°C to +155°C By Type Insulation Resistance IEC 60115-1 4.6 In V-Block for 60 sec. >1,000MΩ Solderability IEC 60115-1 4.17 245±5°C for 3±0.5 Sec. 95% Min. coverage Solvent Resistance of Marking IEC 60115-1 4.30 IPA for 5±0.5 Min. with ultrasonic No deterioration of coatings and markings Robustness of Terminations IEC 60115-1 4.16 Direct load for 10 Sec. in the direction of the terminal leads ≥2.5Kg(24.5N)D Periodic-pulse Overload IEC 60115-1 4.39 4 times RCWV 10,000 cycles (1 Sec. on, 25 Sec.off) ±2.0%+0.05Ω Damp Heat Steady State IEC 60115-1 4.24 40±2°C,90-95% RH for 56 days, loaded with 0.1 times RCWV ±5.0%+0.05Ω Endurance at 70°C IEC 60115-1 4.25 70±2°C at RCWV(or Umax., whichever ±5.0%+0.05Ω Temperature Cycling IEC 60115-1 4.19 -55°C Room Temp. +155°C Room Temp.(5 cycles) ±2.0%+0.05Ω Resistance to Soldering Heat IEC 60115-1 4.18 260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body ±1.0%+0.05Ω Note: RCWV (Rated Continuous Working Voltage): The DC or AC (rms) continuous working voltage corresponding to the rated power is determined by the following formula: V=√(P X R) or max. working voltage whichever is less Where V=Continuous rated DC or AC (rms) working voltage (V) P=Rated power (W) R=Resistance value (Ω)
www.yageo.com Aug. 12, 2024 V.2 Cement Resistors 6 8 Product Specification SLR Through Hole Resistors MARKING Example: YAGEO = Brand 1210 = Date code 3W = Power rating 0R18 = Resistance K = Tolerance
www.yageo.com Aug. 12, 2024 V.2 Cement Resistors 7 8 Product Specification SLR Through Hole Resistors
REVISION HISTORY
REVISION DATE CHANGE NOTIFICATION DESCRIPTION Version 2 Aug.12, 2024 - - Update resistance range Version 1 Aug.31, 2023 - - Revised LEGAL DISCLAIMER Version 0 Aug.2, 2021 - - First issue of this specification “ Yageo reserves all the rights for revising the content of this datasheet without further notification, as long as the products itse lf are unchanged. Any product change will be announced by PCN.”
www.yageo.com Aug. 12, 2024 V.2 Cement Resistors 8 8 Product Specification SLR Through Hole Resistors LEGAL DISCLAIMER YAGEO, its distributors and agents (collectively, “YAGEO”), hereby disclaims any and all liabilities for any errors, inaccuracies or incompleteness contained in any product related information, including but not limited to product specifications, datasheets, pictures and/or graphics. YAGEO may make changes, modifications and/or improvements to product related information at any time and without notice. YAGEO makes no representation, warranty, and/or guarantee about the fitness of its products for any particular purpose or the continuing production of any of its products. To the maximum extent permitted by law, YAGEO disclaims (i) any and all liability arising out of the application or use of any YAGEO product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for a particular purpose, non -infringement and merchantability. YAGEO products are designed for general purpose applications under normal operation and usage conditions. Please contact YAGEO for the applications listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party's life, body or property: Aerospace equipment (artificial satellite, rocket, etc.), Atomic energy-related equipment, Aviation equipment, Disaster prevention equipment, crime prevention equipment, Electric heating apparatus, burning equipment, Highly public information network equipment, data-processing equipment , Medical devices, Military equipment, Power generation control equipment, Safety equipment, Traffic signal equipment, Transportation equipment and Undersea equipment, or for any other application or use in which the failure of YAGEO products could result in personal injury or death, or serious property damage. Particularly YAGEO Corporation and its affiliates do not recommend the use of commercial or automotive grade products for high reliability applications or manned space flight. Information provided here is intended to indicate product specifications only. YAGEO reserves all the rights for revising this content without further notification, as long as products are unchanged. Any product change will be announced by PCN.