SLE ITT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 14

Technical content

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change SLE B P S G Series Prefix Size Number of Contacts Contact Termination Connector Type Connector Termination Mechanical Modifier Material/Finish Modifier Part No. Description

19 Position

28 Position

No. of Contacts Plug, Straight PCB For PCB Layout, see page 24. SLEC28P4S SLEC28P4D SLEC28P4L SLEC28P4SG SLEC28P4R SLEC28P4UG SLEC28P4U SLEC28P4DG SLEB19S2SF SLEB19S2R SLEB19S2S SLEB19S2U SLEB19S2L SLEB19S2D SLEB19T3P SLEB19T3 SLEB19T3PM SLEB19T3H SLEB19T3PN SLEB19N3P SLEB19N3PN SLEB19N3PM SLEB19N3 SLEC28S2SF SLEC28S2R SLEC28S2S SLEC28S2U SLEC28S2L SLEC28S2D SLEC28N3P SLEC28N3PN SLEC28N3PM SLEC28N3 SLEC28T3P SLEC28T3PE SLEC28T3PM SLEC28T3 SLEC28T3PN SLEB130411 SLEB19S12 SLEB130411 SLEB19S14 SLEC130415 SLEC28S12 SLEC130414 SLEC28S14 SLEB19P4S SLEB19P4D SLEB19P4L SLEB19P4SG SLEB19P4R SLEB19P4UG SLEB19P4U SLEB19P4DG 130415-0000 130415-0004 130415-0001 130415-0005 130415-0002 130415-0000 130415-0004 130415-0001 130415-0005 130415-0002 How to Order Snap-Lock Environmentally Sealed - Rectangular Engineering Quick Reference Selection Guide Cannon SLE

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Plug, 90° PCB Receptacle, In-line Plug, In-line For PCB Layout, see page 25 130408-0000 130408-0004 130408-0001 130408-0010 130408-0002 130408-0011 130408-0003 130408-0012 130413-0000 130413-0003 130413-0001 130413-0004 130413-0002 130413-0005 130414-0000 130414-0002 130414-0001 130414-0004 130412-0000 130412-0004 130412-0001 130412-0010 130412-0002 130412-0011 130412-0003 130412-0012 130413-0000 130413-0003 130413-0001 130413-0004 130413-0002 130413-0005 130414-0000 130414-0002 130414-0001 130414-0004 Note: For configuration contact Cannon. Note: For configuration contact Cannon. Series Prefix SLE - SLE-Snap Lock Environmental Size B-19 Cavity Housing C-28 Cavity Housing Number of Contacts 19 or 28 Contact Termination T - Tuning Fork Straight [Plug with 3,05 (.120) min. PCB tails] N - Tuning Fork 90° [Plug with 2,54 (.100) min. PCB tails] P - Crimp Pin (Receptacle) S - Crimp Socket (Plug) P1 - Crimp Pin Power (Receptacle) S1 - Crimp Socket Power (Pin) Connector Type 2 - Plug, In-line (Cable-to-Cable) 3 - Plug, PCB 4 - Receptacle, In-line (Cable-to-Cable) Connector Termination S - Straight (Endbell) L - 90° Left (Endbell) R - 90° Right (Endbell) U - 90° Up (Endbell) D - 90° Down (Endbell) P - Potted (PCB Only) Mechanical Modifier F - With Flange Mount (Plug only) G - Screwlock Applications (Receptacle only) M - Metric Threaded Inserts N - Threaded Inserts #6-32 E - Threaded Inserts #6-32 Snap-Lock Environmentally Sealed - Rectangular Engineering Quick Reference Selection Guide Cannon SLE

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change The Snap Lock Environmental Series is environmentally-sealed connector created for printed circuit board, blackbox, cable-to-cable, or bulkhead applications. When your under-the-hood requirements call for tough performance, the SLE "snaps" into a tightly sealed connection that can withstand heat, shock and vibration. The connector is designed to preserve the integrity of the solid state package, while protecting against contaminants - even when unmated. Polarization, scoop-proofing and hand insertion of contacts are part of the package. Gold, tin/lead-plated stamped contacts add durability. A rugged, thermoplastic receptacle body maximizes performance by withstanding temperature variances from -40°C to +125°C. The SLE series is available in both 19 and 28 contact cavity configurations. It can also be adapted to robotic assembly. Should your requirement demand higher density configurations, consult Customer Service. Superior environmental sealing -40°C to +125°C continuous operation at rated current

  • Available in two sizes, 19 and 28 contacts
  • Crimp stamped gold, tin/lead plated contacts
  • Hand insertable/removable contacts
  • Current rating 5 A and 13 A versions Low millivolt drop Small footprint on P.C. board and low profile 5-way alternate polarization Integral mold latch. Adaptable to robotic assembly. Multi-direction, easily assembled endbells Optional secondary bail latch Latch with tactile and audible feedback Low installed cost Meets both signal and power requirements Versatile cable strain relief, up, down, straight, left ad right, flange/bulkhead Connector mating assurance Contact Resistance Insulation Resistance Current Rating Dielectric Withstanding Voltage Applicable Cannon Specification Operating Temperature Crimp Contacts Wire Size Wire Insulations Sealing Range Polarization Contact Insertion Contact Extraction Contact Retention Wire Strip Length 10 mΩmaximum

100 MΩminimum

5 A signal continuous at 125°C all contacts

13 A power continuous at 125°C all contacts

1000 Vrms AC at sea level

-40°C to +125°C Semi-automatic or hand crimpable 20-16 AWG 'D' shaped interface with five alternate positions. No tool required. Suitable for automation. Rear removable 25 lbs. Minimum per contact Connector Housing Contacts Finish Environmental Seal High temperature thermoplastic Copper alloy Engaging area: Gold over nickel Crimp/P.C. tail area: Tin/lead over nickel High temperature silicone elastomer Snap-Lock Environmentally Sealed - Rectangular Cannon SLE Product Feature and Benefits Performance Specifications Materials and Finishes

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Face View - Engaging Face of Plug Size B

19 Contacts

28 Contacts

Power Version* *Contact Cannon Power Version* Normal W X Y Z Snap-Lock Environmentally Sealed - Rectangular Contact Cavity Arrangement Cannon SLE Polarization

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Connectors are supplied with endbell assemblies. Part number by Shell Size B Max. F Max. Cable Entry I.D. SLEB 26,16 (1.030) 50,80 (2.000) 14,73 (.580) SLEC 26,16 (1.030) 66,04 (2.600) 19,81 (.780) Snap-Lock Environmentally Sealed - Rectangular Endbells Cannon SLE With Flange Endbell (Plug Only) Note: Plugs are supplied with endbell assemblies. SLEB SLEB SLEB SLEB SLEB SLEB SLEC SLEC SLEC SLEC SLEC SLEC 130409-0000* 130409-0001* 130409-0002* 130409-0003* 130409-0004* 130409-0005* 130413-0000 130413-0001 130413-0002 130413-0003 130413-0004 130413-0005 SLEB19S2SF SLEB19S2S SLEB19S2L SLEB19S2R SLEB19S2U SLEB19S2D SLEC28S2SF SLEC28S2S SLEC28S2L SLEC28S2R SLEC28S2U SLEC28S2D 71,88 (2.830) 71,88 (2.830) 71,88 (2.830) 71,88 (2.830) 71,88 (2.830) 71,88 (2.830) 87,11 (3.430) 87,11 (3.430) 87,11 (3.430) 87,11 (3.430) 87,11 (3.430) 87,11 (3.430) 47,50 (1.870) 47,50 (1.870) 47,50 (1.870) 47,50 (1.870) 47,50 (1.870) 47,50 (1.870) 62,74 (2.470) 62,74 (2.470) 62,74 (2.470) 62,74 (2.470) 62,74 (2.470) 62,74 (2.470) 59,05 (2.325) 59,05 (2.325) 59,05 (2.325) 59,05 (2.325) 59,05 (2.325) 59,05 (2.325) 74,29 (2.925) 74,29 (2.925) 74,29 (2.925) 74,29 (2.925) 74,29 (2.925) 74,29 (2.925) Shell Number of D Size Contacts Part Number* Nomenclature A Max. C Max. ±0,38 (.015) *Select polarization, see page 25. Plug, In-line (Cable-to-Cable)

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Snap-Lock Environmentally Sealed - Rectangular Receptacle, In-line (Cable-to-Cable) Cannon SLE 90° Left and Right Straight Screwlock Note: Receptacles are supplied with endbell assemblies. SLEB SLEB SLEB SLEB SLEB SLEB SLEB SLEB SLEC SLEC SLEC SLEC SLEC SLEC SLEC SLEC 130408-0000* 130408-0001* 130408-0002* 130408-0003* 130408-0004* 130408-0010* 130408-0011* 130408-0012* 130412-0000 130412-0001 130412-0002 130412-0003 130412-0004 130412-0010 130412-0011 130412-0012 SLEB19P4S SLEB19P4L SLEB19P4R SLEB19P4U SLEB19P4D SLEB19P4SG SLEB19P4UG SLEB19P4DG SLEC28P4S SLEC28P4L SLEC28P4R SLEC28P4U SLEC28P4D SLEC28P4SG SLEC28P4UG SLEC28P4DG 59,44 (2.340) 59,44 (2.340) 59,44 (2.340) 59,44 (2.340) 59,44 (2.340) 59,44 (2.340) 59,44 (2.340) 59,44 (2.340) 76,45 (3.010) 76,45 (3.010) 76,45 (3.010) 76,45 (3.010) 76,45 (3.010) 76,45 (3.010) 76,45 (3.010) 76,45 (3.010) 44,07 (1.735) 44,07 (1.735) 44,07 (1.735) 44,07 (1.735) 44,07 (1.735) 44,07 (1.735) 44,07 (1.735) 44,07 (1.735) 59,31 (2.335) 59,31 (2.335) 59,31 (2.335) 59,31 (2.335) 59,31 (2.335) 59,31 (2.335) 59,31 (2.335) 59,31 (2.335) 50,58 (2.000) 50,58 (2.000) 50,58 (2.000) 50,58 (2.000) 50,58 (2.000) 50,58 (2.000) 50,58 (2.000) 50,58 (2.000) 66,04 (2.600) 66,04 (2.600) 66,04 (2.600) 66,04 (2.600) 66,04 (2.600) 66,04 (2.600) 66,04 (2.600) 66,04 (2.600) Shell Number of E Size Contacts Part Number* Nomenclature A Max. C Max. D Max. ±0,38 (.015) F Max. *Select polarization, see page 23. 55,87 (2.200) 55,87 (2.200) 55,87 (2.200) 55,87 (2.200) 55,87 (2.200) 55,87 (2.200) 55,87 (2.200) 55,87 (2.200) 71,11 (2.800) 71,11 (2.800) 71,11 (2.800) 71,11 (2.800) 71,11 (2.800) 71,11 (2.800) 71,11 (2.800) 71,11 (2.800) 64,25 (2.530) 64,25 (2.530) 64,25 (2.530) 64,25 (2.530) 64,25 (2.530) 64,25 (2.530) 64,25 (2.530) 64,25 (2.530) 79,49 (3.130) 79,49 (3.130) 79,49 (3.130) 79,49 (3.130) 79,49 (3.130) 79,49 (3.130) 79,49 (3.130) 79,49 (3.130)

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Panel Cutout SLEB SLEB SLEB SLEB SLEB SLEC SLEC SLEC SLEC SLEC 130411-0000* 130411-0001* 130411-0002* 130411-0004* 130411-0005* 130415-0000 130415-0001 130415-0002 130415-0004 130415-0005 SLEB19T3P SLEB19T3PM SLEB19T3PN SLEB19T3E SLEB19T3 SLEC28T3P SLEC28T3PM SLEC28T3PN SLEC28T3PE SLEC28T3 63,50 (2.500) 63,50 (2.500) 63,50 (2.500) 63,50 (2.500) 63,50 (2.500) 78,94 (3.108) 78,94 (3.108) 78,94 (3.108) 78,94 (3.108) 78,94 (3.108) 74,94 (3.100) 74,94 (3.100) 74,94 (3.100) 74,94 (3.100) 74,94 (3.100) 54,61 (2.150) 54,61 (2.150) 54,61 (2.150) 54,61 (2.150) 54,61 (2.150) 56,13 (2.210) 56,13 (2.210) 56,13 (2.210) 56,13 (2.210) 56,13 (2.210) 71,37 (2.810) 71,37 (2.810) 71,37 (2.810) 71,37 (2.810) 71,37 (2.810) 47,62 (1.875) 47,62 (1.875) 47,62 (1.875) 47,62 (1.875) 47,62 (1.875) 62,86 (2.475) 62,86 (2.475) 62,86 (2.475) 62,86 (2.475) 62,86 (2.475) Shell Number of Size Contacts Part Number* Nomenclature A Max. B Max. D Max. E Max. *Select polarization, see page 23. SLE B19 (19 contacts) SLE C28 (28 contacts) Snap-Lock Environmentally Sealed - Rectangular Plug, PCB, Straight Cannon SLE Recommended PCB Layout, Straight A B D 4,80-4,69 (.189-.185) 24,13-23,72 (.950-.930) 18,42-18,03 (.725-.710) CL

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Panel Cutout SLEB SLEB SLEB SLEB SLEC SLEC SLEC SLEC 130410-0000* 130410-0001* 130410-0002* 130410-0004* 130414-0000 130414-0001 130414-0002 130414-0004 SLEB19N3P SLEB19N3PM SLEB19N3PN SLEB19N3 SLEC28N3P SLEC28N3PM SLEC28N3PN SLEC28N3 63,50 (2.500) 63,50 (2.500) 63,50 (2.500) 63,50 (2.500) 78,94 (3.108) 78,94 (3.108) 78,94 (3.108) 78,94 (3.108) 74,94 (3.100) 74,94 (3.100) 74,94 (3.100) 74,94 (3.100) 54,61 (2.150) 54,61 (2.150) 54,61 (2.150) 54,61 (2.150) 35,81 (1.410) 35,81 (1.410) 35,81 (1.410) 35,81 (1.410) 51,05 (2.010) 51,05 (2.010) 51,05 (2.010) 51,05 (2.010) 56,13 (2.210) 56,13 (2.210) 56,13 (2.210) 56,13 (2.210) 71,37 (2.810) 71,37 (2.810) 71,37 (2.810) 71,37 (2.810) 47,62 (1.875) 47,62 (1.875) 47,62 (1.875) 47,62 (1.875) 62,86 (2.475) 62,86 (2.475) 62,86 (2.475) 62,86 (2.475) Shell Number of Size Contacts Part Number* Nomenclature A Max. B Max. C Max. D Max. E Max. *Select polarization, see page 23. SLE B19 (19 contacts) SLE C28 (28 contacts) Snap-Lock Environmentally Sealed - Rectangular Plug, PCB, 90˚ Cannon SLE Recommended PCB Layout, 90˚

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Socket (use in plugs) Hooded Socket Pin (use in receptacles) Hooded Socket Reeled

Description

110238-1016 (030-2480-007) 110238-0446 (030-2464-007) 110238-04888 (030-2480-000) 4,500 13 A 110238-2004 (030-2464-003) 110238-2003 (030-2480-003) 4,000 Sealing Plug Latch Clip Retainer Material: Thermoplastic, Color: Natural Part Number: 225-0093-000 Female Screw Lock Order 2 per connector Material: Steel Finish: Zinc Part Number: 265-0061-000 Bail Latch For Redundant Latch Applications SLEB 029-0281-000 SLEC 029-0281-001 Insulation Resistance Dielectric Withstanding Voltage Contact Resistance Low Level Contact Resistance Crimp Tensile Strength Contact Retention Mating Separating Force Durability Temperature Life Mechanical Shock Maintenance Aging Vibration Sand and Dust Salt and Spray Humidity Steam Cleaning/Pressure Wash MIL-STD-1344 MIL-STD-1344 MIL-STD-1344 MIL-STD-1344 MIL-STD-1344 MIL-STD-1344 MIL-STD-1344 MIL-STD-1344 MIL-STD-202 MIL-STD-202 MIL-STD-1344 MIL-STD-1344 MIL-STD-202 MIL-STD-202 MIL-STD-202 SAE Method 3003.1 Method 3001.1 Method 3004.1 Method 3002.1 Method 2003.1 Method 2007.1 Method 2013.1 Method 2016 Method 108 Condition D Method 213 Condition I Method 2002.1 Method 2005.1 Condition VI 20 Hours/Axis Method 110 Method 101 Condition A Method 106 Proposed Snap-Lock Environmentally Sealed - Rectangular Contacts, Stamped, 5 and 13 Amp Cannon SLE Accessories Test Methods

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Contact Extraction Tool Part Number: 274-7068-001 Tip Part Number: 323-9519-000

  • A Standard CET - SLE/SLC is available for extraction of the individual crimp contacts. Insertion tool is not required. Snap-Lock Environmentally Sealed - Rectangular Extraction Tool Cannon SLE Insertion/Extraction Instructions for Crimp Contacts Insertion Tool No insertion tool is required. The contact is easily snapped in from the rear of the connector manually. 1. Move to the rear of the connector so that the contact cavities can be identified. 2. Insert a crimp terminated assembly into a selected cavity. 3. Continue the forward movement until and audible snap can be felt and heard. Slight pull in the opposite direction will confirm complete insertion. 1. Open the CET - SLE Extraction tool and place it over the insulation of the wire. 2. Using a straight motion forward, insert the tool along the wire until it bottoms against the connector. (Do not use a screwing motion - damage will result.) 3. While the extraction tool is in place, simply pull the wire/contact assembly out. 4. Remove the extraction tool. Extraction is complete. Extraction

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Snap-Lock Environmentally Sealed - Rectangular Hand Crimp Tool Operation Cannon SLE Hand Crimp Tool - CCT - SLC / SLE Part Number: 995-0002-232 The CCT-SLC/SLE hand crimp tool is designed to crimp individual SLC/SLE contacts on wire sizes 16, 18, and 20 AWG. Each cycle is ratchet-controlled (The tool must be completely closed before it can be reopened) to assure a satisfactory crimp each time. Over and under crimps are eliminated. This tool is for use when the requirement is for low to moderate volume quantities, and for on-site applications where semi- automatic tools cannot be practically used. 1. Cycle the CCT - SLE / SLC hand tool to the open position. 2. While pressing upward on the locator spring, insert the contact with tails upward completely into the locator. 3. When correctly positioned the contact should be located beyond flush with the edge of the CCT - SLE / SLC and positioned in the concave polished split level crimp. 4. Partially (usually the first click) Cycle the hand tool assuring that the upward thrusting tails of the contact has started engaging with the top jaw of the tool. (There is a slight tendency for the contact to roll out of vertical alignment.) 5. Insert the pre-stripped wire into the crimp area of the contact and completely cycle the tool. 7. The result will be a perfect termination. 8. Note that there are no unterminated wire strands, and that some strand ends can be seen at the forward edge of the crimp. Also note the insulation is gripped by the smaller secondary crimp. Distortion is at a minimum, both axially and laterally - no sharp edges. 6. While pressing upward on the locator spring withdraw the crimp termination. Wire Stripping 5 and 13 A Contact Tolerance A B Low 2,41 (.095) 5,33 (.210) High 3,30 (.130) 5,59 (.220)

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change ABT-607 Pneumatic Crimper ABT-500 UCCD ABT-620 UCCS The ABT-607 is a pneumatic powered and controlled machine. It is designed for customers with moderate volume. This machine is designed to semi- automatically crimp stamped and formed contacts onto pre-stripped stranded or single conductor electrical wire. This machine will accommodate size 34 thru 12 AWG wire and is actuated by the use of a foot pedal. Machine Crimp Rate: 800 per hour Power Requirements: Pneumatic = 100 psi, 2 cu. ft. per min. The ABT-500 Universal Cannon Crimp Die, is a flywheel driven, electronically controlled machine that is designed to semi-automatically crimp stamped and formed contacts on stranded or single conductor, pre- stripped wire. This machine will accommodate size 34 thru 12 WG wire. The machine is actuated by the use of a foot pedal. Machine Crimp Rate: 1300 per hour Power Requirements: Electrical = 115VAC, 60Hz, 20A The ABT-620 Universal Cannon Crimper/Stripper is a pneumatic powered, microprocessor controlled machine. It is designed to semi-automatically strip insulation from stranded or single conductor electrical wire and attach a stamped and formed contact by crimping. The machine will accommodate 34 thru 12 AWG wire. Primary application of the machine is the termination of jacketed cable where the individual leads cannot be stripped by fully automated equipment. The ABT-620 UCCS operates automatically upon insertion of a wire or it can be switched over to foot pedal operation if desired. Machine Crimp Rate: 1200+ per hour Power Requirements: Electrical = 115VAC, 60Hz, 20A Pneumatic = 80 psi, 3 cu. ft. per min. * For other geographical regions, contact Cannon for details. Snap-Lock Environmentally Sealed - Rectangular Lease Automatic Tooling - North America* Cannon SLE

www.ittcannon.com Dimensions shown in mm Specifications and dimensions subject to change Snap-Lock Environmentally Sealed - Rectangular Crimp Pot Cross Section Cannon SLE Crimp Height and Width Wire Gauge (AWG) D Ref. D Ref. D Ref. Signal (5A) .064* .082 .056* .080 .054* .080 Power (13A) .066* .082 .062* .080 .058* .080 * Hand Tools are ± .002 and machines are ± .001 Insulation Height and Width Wire Gauge (AWG) Height Width Height Width Height Width Max Max Max Max Max Max Signal (5A) .110 .115 .105 .110 .105 .110 Power (13A) .110 .115 .105 .110 .105 .110 Measurements are taken without crimping wire insulation. Crimp Tensile Strength Wire Trim Dimension Wire Size (AWG) Tensile Min (lbs) 35 lbs. 25 lbs. 20lbs. CRIMP POT CROSS SECTION D CRIMP WIDTH C CRIMP HEIGHT (.220 - .210) (.130 - .095) The wire crimp heights listed are only reference and valid for the correspondingly listed wire size, wire plating and wire stranding. The wire crimp tensile values must be used to assure the performance of crimped contacts. For wire crimp information not listed in this table, please contact Cannon.

www.ittcannon.com Specifications and dimensions subject to change Snap-Lock Environmentally Sealed - Rectangular Cannon SLE Test Parameters Environmental Sealing Contact Crimp Tensile Strength Insulation Resistance Dielectric Withstanding Voltage Low Level Contact Resistance Mechanical Shock Vibration Durability Contact Maintenance Aging Mating and Separating Force Solvent Resistance Immersion Temperature Life Thermal Cycling 3.2.3.5 3.2.3.6 3.2.3.7 3.2.3.8 3.2.3.9 3.2.3.10 3.2.2.1 3.2.1.1 3.2.1.2 3.2.1.4 3.2.3.3 3.2.3.4 3.2.2.5 3.2.2.2 3.2.2.3 3.2.2.4 3.2.2.9 3.2.3.1 3.2.3.2 Sand and Dust MIL-STD-202 Method 110 Test Condition A 5% salt spray 96 hours 10 cycles of 24 hours, 90-98% humidity Steam Cleaning/Pressure Wash 95°C, 375 Cycles 750 PSIG Solvent Resistance/Immersion (see 3.2.3.9) Thermal Shock 100 Cycles -40°C to +125°C ± 3°C The minimum tensile load required to separate the wire from the contact, either by pulling the wire out of the crimp joint or by breaking the wire within the crimp joint shall not be less than the applicable limits as specified. Wire breakage or contact damage not due to crimping at less than tensile loads shall not constitute a failure. Wire Size AWG Crimp Tensile Strength, Pounds Minimum Mated and wired connectors shall exhibit an insulation resistance greater than 100 megohms between all contacts. This limit shall apply after exposure to each environment including salt solution immersion. Tests shall be performed at 100 VDC ± 10%. Wired and mated connectors shall show no evidence of breakdown between adjacent contacts when tested at 1000 VDC ± 5%. Connectors shall meet this requirement after exposure to each environment. Current leakage shall be less than 1.0 milliamp. The low level contact resistance of mated contacts shall be less than 10 milliohms when measured across the contacts and crimp joints. The test current shall be a maximum of 100 milliamps with an open circuit test voltage of 20 millivolts maximum. Connectors shall be subjected to three shocks in each direction applied along the three mutually perpendicular axes of the connector test specimen for a total of 12 shocks. Each shock shall consist of a terminal peak sawtooth pulse with a peak value of 100 g's and a duration of 6 milliseconds. Connectors shall be subjected to random vibration in accordance with MIL-STD-1344, Method 2005.1, test condition VI for 20 hours along each of the following three axes: Direction Grms Transverse axis of connector (Y) 22.8 Longitudinal axis of connector (Z) 12.2 Mating axis 10.2 Electrical continuity of the connectors shall be monitored during the last 20 minutes sweep in each axis with a test current of 100 milliamps or less and a test voltage less than 2VDC. Electrical discontinuities in excess of 10 microseconds shall be cause of failure. Connectors shall be subjected to 25 cycles of mating and unmating at room temperature. Following this test there shall be no evidence of damage to the contacts, contact plating, connector housing or seals which may prove detrimental to reliable performance of the connector. Contacts shall not be displaced greater than 0.030 inches from the connector body when a force of 10 pounds is applied. When this test follows maintenance again the same contacts shall be tested. Shall consist of subjecting each wired receptacle to 4 cycles of removal and reinsertion of 20% of the contacts or a minimum of 6 per connector with approved tooling. The maximum force required to mate the plug and receptacle shall be 25 pounds. The maximum force required to separate the plug and receptacle shall be 15 pounds. The rate of travel shall be one inch per minute. Connectors shall be subjected to the following fluids at the temperature and length of time specified. Following the fluid dip or immersion, the connectors shall be immersed to a depth of 2 to 12 inches in a 5% salt-water solution for 24 hours at room temperature. At the completion of the salt-water immersion test, while still immersed, the connectors shall meet the insulation resistance requirement specified herein. Fluid Method Temperature No. 2 Diesel Fluid Immersion (2) 140°F Methyl Alcohol Dip (1) Room Temperature Antifreeze - Prestone Immersion (2) 180°F - 50% Water/50% Immersion (2) 180°F Ethylene Glycol Degreaser - Gunk Dip (1) Room Temperature - Mineral Spirits Dip (1) Room Temperature Paint (Oil Base) Immersion (2) Room Temperature Lubricating Oil Immersion (2) 200°F (SAE 10 W40) Brake Fluid Dip (1) Room Temperature (Delco Supreme) Transmission Fluid Dip (1) Room Temperature fully submerged and pressurized @ 7 psi. (Dextron) (1) Dip: Connectors shall withstand a one second dip and a three minute air dry for a total of 80 cycles. (2) Immersion: Connectors shall withstand immersion for one hour. Connectors shall be subjected to a temperature of 125°C ± 3°C for a period of 1000 hours. At the end of the temperature soak period and after removal from the chamber, the connectors shall meet the insulation resistance and dielectric withstanding voltage requirements specified herein. Connectors shall be operated at rated current throughout the duration of the temperature life test. Upon removal from the chamber at the conclusion of the test, the connectors shall show no visual signs of damage, which may be detrimental to the performance of the connector. Connectors shall be subjected to 100 thermal cycles from -40°C to +125°C. One cycle shall consist of the transitions from room temperature to -40°C to +125°C, and from 125°C to room temperature. One cycle shall be accomplished in a three-hour period with a minimum stabilization period of 15 minutes at each temperature extreme. The chamber temperature transition rate shall be a minimum of 1.30°C per minute and a maximum of 6.00°C per minute. SLC Products are designed to meet Cannon specifications CS-206, CS-210, and CS-216. Items of most general interest to users are designers are listed below. Test