Non-Isolated DC-DC Converter belpowersolutions.com The SLDM-06D1Ax power modules are non-isolated dc-dc converters that can deliver up to 6 A of output current. These modules operate over a wide range of input voltage (VIN = 3 Vdc- 14.4 Vdc) and provide a precisely regulated output voltage from 0.45 Vdc to 5.5 Vdc, programmable via an external resistor and PMBus control. Features include a digital interface using the PMBus protocol, remote On/Off, adjustable output voltage, over current and over temperature protection in the controller. The PMBus interface supports a range of commands to both control and monitor the module. The module also includes the Tunable Loop TM feature that allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area. Key Features & Benefits 3-14.4 VDC Input / 0.45 -5.5 VDC @ 6 A Output Non-Isolated DOSA approved footprint Power Good Signal Remote On/Off Digital interface through the PMBus TM protocol Ability to Sink and Source Current Output Over Current Protection (non-latching) Over Temperature Protection in x 0.11 in) Ultra low height design for very dense power applications. Output voltage programmable from 0.6Vdc to 5.5Vdc via external resistor. Digitally adjustable down to 0.45Vdc Digital interface through the PMBus TM protocol Flexible output voltage sequencing EZ-SEQUENCE Fixed switching frequency with capability of external synchronization Tunable Loop TM to optimize dynamic output voltage response
tech.support@psbel.com belpowersolutions.com Key Features & Benefits (Continued) Wide operating temperature range [-40°C to 105°C]. Compliant to IPC-9592 (September 2008), Category 2, Class II ISO 9001 and ISO 14001 certified manufacturing facilities Compliant to RoHS II EU “Directive 2011/65/EU” Compliant to REACH Directive (EC) No 1907/2006 Compatible in a Pb-free or SnPb reflow environment UL 60950-1Recognized, CSA C22.2 No. 60950-1-03 Certified VDE 0805:2001-12 (EN60950-1) Licensed
Applications
Distributed power architectures Intermediate bus voltage applications Telecommunications equipment Servers and storage applications Networking equipment Industrial equipmen
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 1. MODEL SELECTION MODEL NUMBER OUTPUT VOLTAGE INPUT VOLTAGE MAX. OUTPUT CURRENT MAX. OUTPUT POWER TYPICAL EFFICIENCY SLDM-06D1A0 0.45-5.5 VDC 3-14.4 VDC 33 W 91.5% SLDM-06D1AL 0.45-5.5 VDC 3-14.4 VDC 6A 33 W 91.5% NOTE: 1. Add “R” suffix at the end of the model number to indicate tape and reel packaging (Standard). 2. Add “G” suffix at the end of the model number to indicate tray packaging (Option). S LDM D x Y Mounting Type RoHS Status Output Current Wide input voltage range Output Voltage Enable Package Type Surface mount Series code 6 A 3-14.4V With sequencing L active L ow 0 –active High G Tray package R –tape and reel packaging 2. ABSOLUTE MAXIMUM RATINGS PARAMETER
DESCRIPTION
Continuous non-operating Input Voltage -0.3 - 15 V Voltage on SEQ SYNC VS+ V Voltage on CLK DATA SMBALERT terminal - - 3.6 V Ambient temperature See Thermal Considerations section -40 105 Storage Temperature -55 125 Altitude 2000 m NOTE: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. 3. INPUT SPECIFICATIONS All specifications are typical at 25°C unless otherwise stated. PARAMETER Operating Input Voltage 3 - 14.4 V Input Current (full load) VIN=3V to 14V, IO=IO, max A Input Current (no load) Vo=0.6V Vo=5V VIN = 12Vdc, IO = 0, module enabled 178.7 mA mA Input Stand-by Current V IN = 12.0Vdc, module disabled mA Input Reflected Ripple Current (pk-pk) 5Hz to 20MHz, 1μH source impedance; VIN =0 to 14V, IO= IOmax 2. See Test Configurations 37.6 mA I t Inrush Current Transient A2s Input Ripple Rejection (120Hz) -55 dB CAUTION: This converter is not internally fused. An input line fuse must be used in application. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6A. Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. Note: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. PART NUMBER EXPLANATION
tech.support@psbel.com belpowersolutions.com 4. OUTPUT SPECIFICATIONS All specifications are typical at nominal input, full load at 25°C unless otherwise stated. PARAMETER with 0.1% tolerance for external resistor used to set output voltage -1.0 1.0 %Vo,set Output Voltage Over all operating input voltage, resistive load, and temperature conditions until end of life -0.3 - 0.3 %Vo,set PMBus Adjustable Output Voltage Range -25 %Vo,set PMBus Output Voltage Adjustment Step Size 0.4 - - %Vo,set Adjustment Range 1.Some output voltages may not be possible depending on the input voltage – see Feature Descriptions Section 2.Selected by an extermal resistor. 0.6 5.5 V Remote Sense Range - - 0.5 V Load Regulation V O ≥ 2.5V V O < 2.5V I O O, min to I O, max mV mV Line Regulation V O ≥ 2.5V V O < 2.5V V IN IN , min to V IN, max 0.4 %Vo,set mV Temperature Regulation T ref A, min to T A, max 0.4 %Vo,set Ripple and Noise(Pk-Pk) 5Hz to 20MHz BW, VIN=VIN, nom and I O min to I O, max Co = 0.1uF // 22 uF ceramic capacitors) - 50 100 mV Ripple and Noise(RMS) - 20 38 mV Output Current Range in either sink or source mode A Output Current Limit Inception Current limit does not operate in sink mode 130 %Io,max Output Short-Circuit Current Vo≤250mV, Hiccup Mode 1.3 Arms Output Capacitance ESR≥ 1 mΩ ESR≥0.15 mΩ ESR≥ 10 mΩ Without the Tunable Loop TM With the Tunable Loop TM With the Tunable Loop TM 1x47 2x47 2x47 2x47 1000 5000 uF uF uF Turn-On Delay Times (VIN=VIN, nom, IO=IO, max , VO to within ±1% of steady state) Case 1: On/Off input is enabled and then input power is applied(delay from instant at which VIN = VIN, min until Vo = 10% of Vo, set) 0.4 ms Case 2: Input power is applied for at least one second and then the On/Off input is enabled (delay from instant at which Von/Off is enabled until Vo = 10% of Vo, set) 0.8 ms Notes: 1. Some output voltages may not be possible depending on the input voltage. 2. External capacitors may require using the new Tunable Loop TM feature to ensure that the module is stable as well as getting the best transient response (See the Tunable Loop TM section for details). 3. Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 5. GENERAL SPECIFICATIONS PARAMETER Vo=0.6V Vo=1.2V Vo=1.8V Vo=2.5V Vo=3.3V Vo=5.0V Vin= 12Vdc, Ta=25°C Io=Io, max , Vo= Vo,set 82.5 86.1 88.0 89.4 91.5 Switching Frequency - 800 - kHz Synchronization Frequency Range 760 800 840 kHz High-Level Input Voltage 2.0 - - V Low-Level Input Voltage 0.4 V Input Current, SYNC - - 100 nA Minimum Pulse Width, SYNC 100 ns Maximum SYNC rise time 100 - - ns Over Temperature Protection 130 PMBus Over Temperature Warning Threshold 120 PMBus Adjustable Input Under Voltage Lockout Thresholds 2.5 V Resolution of Adjustable Input Under Voltage Threshold 500 mV Input Undervoltage Lockout Turn-on Threshold Turn-off Threshold Hysteresis 2.475 3.025 V 2.25 2.75 V 0.2 V Tracking Accuracy Power-Up: 2V/ms Power-Down: 2V/ms Vin, min to Vin, max; Io, min to Io, max, Vseq < Vo 100 100 mV mV PGOOD (Power Good) Overvoltage threshold for PGOOD ON Overvoltage threshold for PGOOD OFF Undervoltage threshold for PGOOD ON Undervoltage threshold for PGOOD OFF Pulldown resistance of PGOOD pin Sink current capability into PGOOD pin Signal Interface Open Drain, Vsupply 5Vdc 108 %Vo,set %Vo,set %Vo,set %Vo,set Ω mA Weight 1.186 g MTBF Calculated MTBF (IO=0.8IO, max, TA=40°C) Telecordia Issue 2 Method 1 Case 3 77,807,049 hours Dimensions Inches (L × W × H) Millimeters (L × W × H) 0.8 x 0.45 x 0.11 20.32 x 11.43 x 2.8 Inches Millimeters Note: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions
tech.support@psbel.com belpowersolutions.com 6. DIGITAL INTERFACE SPECIFICATIONS PARAMETER PMBus Signal Interface Characteristics Input High Voltage (CLK, DATA) 2.1 3.6 V Input Low Voltage (CLK, DATA) 0.8 V Input high level current (CLK, DATA) -10 uA Input low level current (CLK, DATA) -10 uA Output Low Vo ltage (CLK, DATA, SMBALERT#) I out =2mA 0.4 V Output high level open drain leakage current (DATA, SMBALERT#) Vout =3.6V uA Pin capacitance 0.7 pF PMBus Operating frequency range 400 kHZ Data setup time 250 ns Data hold time Receive Mode Transmit Mode 300 ns Measurement System Characteristics Read delay time 153 192 231 us Output current measurement range A Output current measurement resolution 62.5 mA Output current measureme nt gain accuracy Output current measurement offset 0.1 A V OUT measurement range 5.5 V V OUT measurement resolution 15.625 mA V OUT measurement gain accuracy -15 V OUT measurement offset V IN measurement range 14.4 V V IN measurement resolution 32.5 mV V IN measurement gain accuracy -15 V IN measurement offset -5.5 1.4 LSB
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 7. EFFICIENCY DATA EFFICIENCY, (%) EFFICIENCY, (%) OUTPUT CURRENT, I O (A) OUTPUT CURRENT, I O (A) Vo=0.6V Vo=1.2V EFFICIENCY, (%) EFFICIENCY, (%) OUTPUT CURRENT, I O (A) OUTPUT CURRENT, I O (A) Vo=1.8V Vo=2.5V EFFICIENCY, (%) EFFICIENCY, (%) OUTPUT CURRENT, I O (A) OUTPUT CURRENT, I O (A) Vo=3.3V Vo=5.0V
tech.support@psbel.com belpowersolutions.com 8. THERMAL DERATING CURVE OUTPUT CURRENT, Io (A) OUTPUT CURRENT, Io (A) AMBIENT TEMPERATURE, T A O C AMBIENT TEMPERATURE, T A O C Vo=0.6V Vo=1.2V OUTPUT CURRENT, Io (A) OUTPUT CURRENT, Io (A) AMBIENT TEMPERATURE, T A O C AMBIENT TEMPERATURE, T A O C Vo=1.8V Vo=2.5V OUTPUT CURRENT, Io (A) OUTPUT CURRENT, Io (A) AMBIENT TEMPERATURE, T A O C AMBIENT TEMPERATURE, T A O C Vo=3.3V Vo=5.0V
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 9. RIPPLE AND NOISE WAVEFORMS OUTPUT VOLTAGE VO (V) (10mV/div) OUTPUT VOLTAGE VO (V) (20mV/div) TIME, t ( 200n s/div) TIME, t ( 200ns /div) Vo=0.6V, Io = Io,max Vo=1.2V, Io = Io,max OUTPUT VOLTAGE VO (V) (20mV/div) OUTPUT VOLTAGE VO (V) (20mV/div) TIME, t (200ns/div) TIME, t (200ns/div) Vo=1.8V, Io = Io,max Vo=2.5V, Io = Io,max OUTPUT VOLTAGE VO (V) (20mV/div) OUTPUT VOLTAGE VO (V) (50mV/div) TIME, t ( 200ns /div) TIME, t ( 200ns /div) Vo=3.3V, Io = Io,max Notes: Co=1x47uF ceramic, VIN= 12V, Io = Io,max Vo=5.0V, Io = Io,max
tech.support@psbel.com belpowersolutions.com 10. TRANSIENT RESPONSE WAVEFORMS Note: Transient Response to Dynamic Load Change from 50% to 100% at 12Vin OUTPUT CURRENT, OUTPUT VOLTAGE IO (A) (2Adiv) VO (V) (20mV/div) OUTPUT CURRENT, OUTPUT VOLTAGE IO (A) (2Adiv) VO (V) (20mV/div) TIME, t (20s /div) TIME, t (20s /div) Vo=0.6V, Cout=3x47uF+3x330uF, CTune=15nF, RTune=200Ω Vo=1.2V, Cout=3x47uF+1x330uF, CTune=4700pF, RTune=300Ω OUTPUT CURRENT, OUTPUT VOLTAGE IO (A) (2Adiv) VO (V) (20mV/div) OUTPUT CURRENT, OUTPUT VOLTAGE IO (A) (2Adiv) VO (V) (50mV/div) TIME, t (20s /div) TIME, t (20s /div) Vo=1.8V, Cout=2x47uF+1x330uF, CTune=2700pF, RTune=300Ω Vo=2.5V, Cout=4x47uF, CTune=2700pF, RTune=300Ω OUTPUT CURRENT, OUTPUT VOLTAGE IO (A) (2Adiv) VO (V) (50mV/div) OUTPUT CURRENT, OUTPUT VOLTAGE IO (A) (2Adiv) VO (V) (50mV/div) TIME, t (20s /div) TIME, t (20s /div) Vo=3.3V, Cout=4x47uF, CTune=2700pF, RTune=300Ω Vo=5.0V, Cout=3x47uF, CTune=1500pF, RTune=300Ω
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 11. STARTUP TIME ON/OFF VOLTAGE OUTPUT VOLTAGE V ON/OFF (V) (5V/div) V O (V) (200mV/div) ON/OFF VOLTAGE OUTPUT VOLTAGE V ON/OFF (V) (5V/div) V O (V) (500mV/div) TIME, t (2 ms/div) TIME, t (2 ms/div) Start-up Using On/Off Voltage (Io = Io,max), Vo=0.6V Start-up Using On/Off Voltage (Io = Io,max), Vo=1.2V ON/OFF VOLTAGE OUTPUT VOLTAGE VON/OFF (V) (5V/div) VO (V) (500mV/div) ON/OFF VOLTAGE OUTPUT VOLTAGE VON/OFF (V) (5V/div) VO (V) (1V/div) TIME, t (2 ms/div) TIME, t (2 ms/div) Start-up Using On/Off Voltage (Io = Io,max), Vo=1.8V Start-up Using On/Off Voltage (Io = Io,max), Vo=2.5V ON/OFF VOLTAGE OUTPUT VOLTAGE VON/OFF (V) (5V/div) VO (V) (1V/div) ON/OFF VOLTAGE OUTPUT VOLTAGE VON/OFF (V) (5V/div) VO (V) (2V/div) TIME, t (2 ms/div) TIME, t (2 ms/div) Start-up Using On/Off Voltage (Io = Io,max), Vo=3.3V Start-up Using On/Off Voltage (Io = Io,max), Vo=5.0V
tech.support@psbel.com belpowersolutions.com STARTUP TIME CONTINUED ON/OFF VOLTAGE OUTPUT VOLTAGE V in (V) (5V/div) V O (V) (200mV/div) ON/OFF VOLTAGE OUTPUT VOLTAGE V in (V) (5V/div) V O (V) (500mV/div) TIME, t (2 ms/div) TIME, t (2 ms/div) Start-up Using Input Voltage (VIN = 12V, Io = Io,max ), Vo=0.6V Start-up Using Input Voltage (VIN = 12V, Io = Io,max ), Vo=1.2V ON/OFF VOLTAGE OUTPUT VOLTAGE V in (V) (5V/div) V O (V) (500mV/div) INPUT VOLTAGE OUTPUT VOLTAGE V in (V) (5V/div) V O (V) (1V/div) TIME, t (2 ms/div) TIME, t (2 ms/div) Start-up Using Input Voltage (VIN = 12V, Io = Io,max ), Vo=1.8V Start-up Using Input Voltage (VIN = 12V, Io = Io,max ), Vo=2.5V ON/OFF VOLTAGE OUTPUT VOLTAGE V in (V) (5V/div) V O (V) (1V/div) ON/OFF VOLTAGE OUTPUT VOLTAGE V in (V) (5V/div) V O (V) (2V/div) TIME, t (2 ms/div) TIME, t (2 ms/div) Start-up Using Input Voltage (VIN = 12V, Io = Io,max ), Vo=3.3V Start-up Using Input Voltage (VIN = 12V, Io = Io,max ), Vo=5.0V
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 12. INPUT FILTERING The SLDM-06D1Ax module should be connected to a low ac-impedance source. A highly inductive source can affect the stability of the module. An input capacitance must be placed directly adjacent to the input pin of the module, to minimize input ripple voltage and ensure module stability. To minimize input voltage ripple, ceramic capacitors are recommended at the input of the module. Figure 37 shows the input ripple voltage for various output voltages at 6A of load current with 1x22 µF or 2x22 µF ceramic capacitors and an input of 12V. Figure 37 Note: Input ripple voltage for various output voltages with 1x22 µF or 2x22 µF ceramic capacitors at the input (6A load). Input voltage is 12V. 100 200 300 400 500 600 1x22uF 2x22 uF
tech.support@psbel.com belpowersolutions.com 13. OUTPUT FILTERING These modules are designed for low output ripple voltage and will meet the maximum output ripple specification with suggested 2x0.047µF+1x1uF ceramic decoupling capacitors and 1x47 µF ceramic capacitors at the output of the module. However, additional output filtering may be required by the system designer for a number of reasons. First, there may be a need to further reduce the output ripple and noise of the module. Second, the dynamic response characteristics may need to be customized to a particular load step change. To reduce the output ripple and improve the dynamic response to a step load change, additional capacitance at the output can be used. Low ESR polymer and ceramic capacitors are recommended to improve the dynamic response of the module. Figure 38 provides output ripple information, measured with a scope with its Bandwidth limited to 20MHz for different external capacitance values at various Vo and a full load current of 6A. For stable operation of the module, limit the capacitance to less than the maximum output capacitance as specified in the electrical specification table. Optimal performance of the module can be achieved by using the Tunable LoopTM feature described later in this data sheet. Figure 38 Note: Output ripple voltage for various output voltages with external 2x47 µF, 4x47 µF, 6x47 µF or 8x47 µF ceramic capacitors at the output (6A load). Input voltage is 12V. 14. SAFETY CONSIDERATIONS For safety agency approval the power module must be installed in compliance with the spacing and separation requirements of the end- use safety agency standards, i.e., UL 60950-1 2nd, CSA C22.2 No. 60950-1-07, DIN EN 60950-1:2006 + A11 (VDE0805 Teil 1 + A11):2009-11; EN 60950-1:2006 + A11:2009-03. For the converter output to be considered meeting the requirements of safety extra-low voltage (SELV), the input must meet SELV requirements. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. The input to these units is to be provided with a fast acting fuse (for example, Bel Fuse SMM series) with a maximum rating of 20 A in the positive input lead. Ripple (mVp-p) Output Voltage(Volts) 1x47uF Ext Cap 2x47uF Ext Cap 4x47uF Ext Cap
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 15. R EMOTE ON/OFF PARAMETER Signal Low (Unit On) Active Low The remote on/off pin open, Unit on. -0.2 0.6 V Signal High (Unit Off) 2.0 Vin,max V Signal Low (Unit Off) Active High The remote on/off pin open, Unit on. -0.2 0.6 V Signal High (Unit On) 2.0 Vin,max V The module can be turned ON and OFF either by using the ON/OFF pin (Analog interface) or through the PMBus interface (Digital). The module can be configured in a number of ways through the PMBus interface to react to the two ON/OFF inputs: Module ON/OFF can be controlled only through the analog interface (digital interface ON/OFF commands are ignored). Module ON/OFF can be controlled only through the PMBus interface (analog interface is ignored). Module ON/OFF can be controlled by either the analog or digital interface. The default state of the module (as shipped from the factory) is to be controlled by the analog interface only. If the digital interface is to be enabled, or the module is to be controlled only through the digital interface, this change must be made through the PMBus. These changes can be made and written to non-volatile memory on the module so that it is remembered for subsequent use.
tech.support@psbel.com belpowersolutions.com 21. OUTPUT TRIM EQUATIONS Without an external resistor between Trim and SIG_GND pins, the output of the module will be 0.6Vdc.To calculate the value of the trim resistor, Rtrim for a desired output voltage, should be as per the following equation: kVoRtrim 6 . 0 Rtrim is the external resistor in KΩ Vo is the desired output voltage. Table 1 provides Rtrim values required for some common output voltages. Table 1 VO, set (V) Rtrim (KΩ) 0.6 Open 0.9 1.0 1.2 1.5 13.33 1.8 2.5 6.316 3.3 4.444 5.0 2.727 22. DIGITAL OUTPUT VOLTAGE ADJUSTMENT Please see the Digital Feature Descriptions section. 23. REMOTE SENSE The SLDM-06D1Ax power module has a Remote Sense feature to minimize the effects of distribution losses by regulating the voltage between the sense pins (VS+ and VS-). The voltage drop between the sense pins and the VOUT and GND pins of the module should not exceed 0.5V.
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 24. VOLTAGE MARGINING Output voltage margining can be implemented in the module by connecting a resistor, Rmargin-up, from the Trim pin to the ground pin for margining-up the output voltage and by connecting a resistor, Rmargin-down, from the Trim pin to output pin for margining-down. Figure 43 shows the circuit configuration for output voltage margining. Please consult your local Bel Power technical representative for additional details. Figure 43 Circuit Configuration for margining Output voltage 25. DIGITAL OUTPUT VOLTAGE MARGINING Please see the Digital Feature Descriptions section. Vo MODULE SIG_GND Trim Rtrim Rmargin up Rmargin down
tech.support@psbel.com belpowersolutions.com 26. OUTPUT VOLTAGE SEQUENCING The SLDM-06D1Ax module includes a sequencing feature, EZ-SEQUENCE that enables users to implement various types of output voltage sequencing in their applications. This is accomplished via an additional sequencing pin. When not using the sequencing feature, leave it unconnected. The voltage applied to the SEQ pin should be scaled down by the same ratio as used to scale the output voltage down to the reference voltage of the module. This is accomplished by an external resistive divider connected across the sequencing voltage before it is fed to the SEQ pin as shown in Fig. 44. In addition, a small capacitor (suggested value 100pF) should be connected across the lower resistor R1. For SLDM-06D1x modules, the minimum recommended delay between the ON/OFF signal and the sequencing signal is 10ms to ensure that the module output is ramped up according to the sequencing signal. This ensures that the module soft-start routine is completed before the sequencing signal is allowed to ramp up. Figure 44 Circuit showing connection of the sequencing signal to the SEQ pin When the scaled down sequencing voltage is applied to the SEQ pin, the output voltage tracks this voltage until the output reaches the set-point voltage. The final value of the sequencing voltage must be set higher than the set-point voltage of the module. The output voltage follows the sequencing voltage on a one-to-one basis. By connecting multiple modules together, multiple modules can track their output voltages to the voltage applied on the SEQ pin. The module’s output can track the SEQ pin signal with slopes of up to 0.5V/msec during power-up or power-down. To initiate simultaneous shutdown of the modules, the SEQ pin voltage is lowered in a controlled manner. The output voltage of the modules tracks the voltages below their set-point voltages on a one-to-one basis. A valid input voltage must be maintained until the tracking and output voltages reach ground potential. Note that in all digital Bel series of modules, the PMBus Output Undervoltage Fault will be tripped when sequencing is employed. This will be detected using the STATUS_WORD and STATUS_VOUT PMBus commands. In addition, the SMBALERT# signal will be asserted low as occurs for all faults and warnings. To avoid the module shutting down due to the Output Undervoltage Fault, the module must be set to continue operation without interruption as the response to this fault (see the description of the PMBus command VOUT_UV_FAULT_RESPONSE for additional information) 27. OVERCURRENT PROTECTION To provide protection in a fault (output overload) condition, the unit is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters hiccup mode. The unit operates normally once the output current is brought back into its specified range. 28. DIGITAL ADJUSTABLE OVERCURRENT WARNING Please see the Digital Feature Descriptions section. 29. OVERTEMPERATURE PROTECTION To provide protection in a fault condition, the unit is equipped with a thermal shutdown circuit. The unit will shut down if the overtemperature threshold of 150oC(typ) is exceeded at the thermal reference point Tref .Once the unit goes into thermal shutdown it will then wait to cool before attempting to restart. 100 pF Module R1=Rtrim 20K SIG_GND SEQ SEQ V
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 30. DIGITAL TEMPERATURE STATUS VIA PMBUS Please see the Digital Feature Descriptions section. 31. DIGITAL ADJUSTABLE OUTPUT OVER AND UNDER VOLTAGE PROTECTION Please see the Digital Feature Descriptions section 32. INPUT UNDERVOLTAGE LOCKOUT At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will begin to operate at an input voltage above the undervoltage lockout turn-on threshold. 33. DIGITAL ADJUSTABLE INPUT UNDERVOLTAGE LOCKOUT Please see the Digital Feature Descriptions section 34. DIGITAL ADJUSTABLE POWER GOOD THERSHOLDS Please see the Digital Feature Descriptions section 35. SYNCHRONIZATION The module switching frequency can be synchronized to a signal with an external frequency within a specified range. Synchronization can be done by using the external signal applied to the SYNC pin of the module as shown in Fig. 45, with the converter being synchronized by the rising edge of the external signal. The Electrical Specifications table specifies the requirements of the external SYNC signal. If the SYNC pin is not used, the module should free run at the default switching frequency. If synchronization is not being used, connect the SYNC pin to GND. Figure 45 MODULE SYNC GND External source connections to synchronize switching frequency of the module. 36. MEASURING OUTPUT CURRENT, OUTPUT VOLTAGE AND INPUT VOLTAGE Please see the Digital Feature Descriptions section.
tech.support@psbel.com belpowersolutions.com 37. TUNABLE LOOP TM The SLDM-06D1Ax has a feature that optimizes transient response of the module called Tunable Loop TM External capacitors are usually added to the output of the module for two reasons: to reduce output ripple and noise (see Figure 38) and to reduce output voltage deviations from the steady-state value in the presence of dynamic load current changes. Adding external capacitance however affects the voltage control loop of the module, typically causing the loop to slow down with sluggish response. Larger values of external capacitance could also cause the module to become unstable. The Tunable Loop TM allows the user to externally adjust the voltage control loop to match the filter network connected to the output of the module. The Tunable Loop TM is implemented by connecting a series R-C between the VS+ and TRIM pins of the module, as shown in Fig. 46. This R-C allows the user to externally adjust the voltage loop feedback compensation of the module. Figure 46 Circuit diagram showing connection of R TUME and C TUNE to tune the control loop of the module Recommended values of RTUNE and CTUNE for different output capacitor combinations are given in Table 2. Table 2 shows the recommended values of RTUNE and CTUNE for different values of ceramic output capacitors up to 1000uF that might be needed for an application to meet output ripple and noise requirements. Selecting RTUNE and CTUNE according to Table 2 will ensure stable operation of the module. In applications with tight output voltage limits in the presence of dynamic current loading, additional output capacitance will be required. Table 3 lists recommended values of RTUNE and CTUNE in order to meet 2% output voltage deviation limits for some common output voltages in the presence of a 3A to 6A step change (50% of full load), with an input voltage of 12V. Please contact your Bel representative to obtain more details of this feature as well as for guidelines on how to select the right value of external R-C to tune the module for best transient performance and stable operation for other output capacitance values. Table 2 Co 3x47F 4x47F 6x47F 10x47F 20x47F R TUNE 330 300 300 240 180 C TUNE 1000pF 1200pF 2200pF 3300pF 8200pF General recommended values of of RTUNE and CTUNE for Vin=12V and various external ceramic capacitor combinations. Table 3.Recommended values of R TUNE and C TUNE to obtain transient deviation of 2% of Vout for a 3A step load with Vin=12V. Vo 3.3V 2.5V 1.8V 1.2V 0.6V Co 3x47F Ceramic 3x47F Ceramic 4x47F Ceramic 1x47F 1x330 F Polymer 1x47F 1x330 F Polymer 2x47F 3x330 F Polymer R TUNE 300 300 300 300 300 200 C TUNE 1000pF 1200pF 1800pF 2700pF 399pF 15nF 60mV 54mV 42mV 26mV 22mV 11mV Recommended values of RTUNE and CTUNE to obtain transient deviation of 2% of Vout for a 3A step load with Vin=12V Note: The capacitors used in the Tunable Loop tables are 47 μF/3 mΩ ESR ceramic and 330 μF/12 mΩ ESR polymer capacitors VS+ MODULE SIG_GND TRIM VOUT RTune CTune RTrim CO GND
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 38. PMBUS INTERFACE CAPABILITY The SLDM-06D1Ax power modules have a PMBus interface that supports both communication and control. The PMBus Power Management Protocol Specification can be obtained from www.pmbus.org.The modules support a subset of version 1.1 of the specification (see Table 6 for a list of the specific commands supported). Most module parameters can be programmed using PMBus and stored as defaults for later use. All communication over the module PMBus interface must support the Packet Error Checking (PEC) scheme. The PMBus master must generate the correct PEC byte for all transactions, and check the PEC byte returned by the module. The module also supports the SMBALERT# response protocol whereby the module can alert the bus master if it wants to talk. For more information on the SMBus alert response protocol, see the System Management Bus (SMBus) specification. The module has non-volatile memory that is used to store configuration settings. Not all settings programmed into the device are automatically saved into this non-volatile memory, only those specifically identified as capable of being stored can be saved (see Table 6 for which command parameters can be saved to non-volatile storage). 39. PMBUS DATA FORMAT For commands that set thresholds, voltages or report such quantities, the module supports the “Linear” data format among the three data formats supported by PMBus. The Linear Data Format is a two byte value with an 11-bit, two’s complement mantissa and a 5-bit, two’s complement exponent. The format of the two data bytes is shown below: Data Byte High Data Byte Low Exponent MSB Mantissa MSB The value is of the number is then given by Value = Mantissa x 2 Exponent
tech.support@psbel.com belpowersolutions.com 40. PMBUS ADDRESSING The power module can be addressed through the PMBus using a device address. The module has 64 possible addresses (0 to 63 in decimal) which can be set using resistors connected from the ADDR0 and ADDR1 pins to SIG_GND. Note that some of these addresses (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 12, 40, 44, 45, 55 in decimal) are reserved according to the SMBus specifications and may not be useable. The address is set in the form of two octal (0 to 7) digits, with each pin setting one digit. The ADDR1 pin sets the high order digit and ADDR0 sets the low order digit. The resistor values suggested for each digit are shown in Table 4 (1% tolerance resistors are recommended). Note that if either address resistor value is outside the range specified in Table 4, the module will respond to address 127. Table 4 Digit Resistor Value (KΩ) 15.4 23.7 36.5 54.9 84.5 130 200 The user must know which I C addresses are reserved in a system for special functions and set the address of the module to avoid interfering with other system operations. Both 100kHz and 400kHz bus speeds are supported by the module. Connection for the PMBus interface should follow the High Power DC specifications given in section 3.1.3 in the SMBus specification V2.0 for the 400kHz bus speed or the Low Power DC specifications in section 3.1.2. The complete SMBus specification is available from the SMBus web site, smbus.org. Figure 48 Circuit showing connection of resistors used to set the PMBus address of the module. ADDR0 SIG_GND R ADDR0 R AD DR 1 ADDR1
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 41. PMBUS ENABLE ON/OFF The module can also be turned on and off via the PMBus interface. The OPERATION command is used to actually turn the module on and off via the PMBus, while the ON_OFF_CONFIG command configures the combination of analog ON/OFF pin input and PMBus commands needed to turn the module on and off. Bit [7] in the OPERATION command data byte enables the module, with the following functions: 0 : Output is disabled 1 : Output is enabled This module uses the lower five bits of the ON_OFF_CONFIG data byte to set various ON/OFF options as follows: Bit Position Access r/w r/w r/w r/w r Function PU CMD CPR POL CPA Default Value PU: Sets the default to either operate any time input power is present or for the ON/OFF to be controlled by the analog ON/OFF input and the PMBus OPERATION command. This bit is used together with the CP, CMD and ON bits to determine startup. Bit Value Action Module powers up any time power is present regardless of state of the analog ON/OFF pin Module does not power up until commanded by the analog ON/OFF pin and the OPERATION command as programmed in bits [2:0] of the ON_OFF_CONFIG register. CMD: The CMD bit controls how the device responds to the OPERATION command. Bit Value Action Module ignores the ON bit in the OPERATION command Module responds to the ON bit in the OPERATION command CPR: Sets the response of the analog ON/OFF pin. This bit is used together with the CMD, PU and ON bits to determine startup. Bit Value Action Module ignores the anal og ON/OFF pin, i.e. ON/OFF is only controlled through the PMBUS via the OPERATION command Module requires the analog ON/OFF pin to be asserted to start the unit
tech.support@psbel.com belpowersolutions.com 42. PMBUS ADJUSTABLE SOFT START RISE TIME The soft start rise time can be adjusted in the module via PMBus. When setting this parameter, make sure that the charging current for output capacitors can be delivered by the module in addition to any load current to avoid nuisance tripping of the overcurrent protection circuitry during startup. The TON_RISE command sets the rise time in ms, and allows choosing soft start times between 600μs and 9ms, with possible values listed in Table 5. Note that the exponent is fixed at -4 (decimal) and the upper two bits of the mantissa are also fixed at 0 Table 5 Rise Time Exponent Mantissa 600μs 11100 00000001010 900μs 11100 00000001110 1.2ms 11100 00000010011 1.8ms 11100 00000011101 2.7ms 11100 00000101011 4.2ms 11100 00001000011 6.0ms 11100 00001100000 9.0ms 11100 00010010000 43. OUTPUT VOLTAGE ADJUSTMENT USING THE PMBUS The VOUT_SCALE_LOOP parameter is important for a number of PMBus commands related to output voltage trimming, margining, over/under voltage protection and the PGOOD thresholds. The output voltage of the module is set as the combination of the voltage divider formed by RTrim and a 20kΩ upper divider resistor inside the module, and the internal reference voltage of the module. The reference voltage VREF is nominally set at 600mV, and the output regulation voltage is then given by Hence the module output voltage is dependent on the value of RTrim which is connected external to the module. The information on the output voltage divider ratio is conveyed to the module through the VOUT_SCALE_LOOP parameter which is calculated as follows: The VOUT_SCALE_LOOP parameter is specified using the “Linear” format and two bytes. The upper five bits [7:3] of the high byte are used to set the exponent which is fixed at –9 (decimal). The remaining three bits of the high byte [2:0] and the eight bits of the lower byte are used for the mantissa. The default value of the mantissa is 00100000000 corresponding to 256 (decimal), corresponding to a divider ratio of 0.5. The maximum value of the mantissa is 512 corresponding to a divider ratio of 1. Note that the resolution of the VOUT_SCALE_LOOP command is 0.2%. When PMBus commands are used to trim or margin the output voltage, the value of VREF is what is changed inside the module, which in turn changes the regulated output voltage of the module. The nominal output voltage of the module can be adjusted with a minimum step size of 0.4% over a ±25% range from nominal using the VOUT_TRIM command over the PMBus. The VOUT_TRIM command is used to apply a fixed offset voltage to the output voltage command value using the “Linear” mode with the exponent fixed at –10 (decimal). The value of the offset voltage is given by This offset voltage is added to the voltage set through the divider ratio and nominal VREF to produce the trimmed output voltage. The valid range in two’s complement for this command is –4000h to 3FFFh. The high order two bits of the high byte must both be either 0 or 1. If a value outside of the +/-25% adjustment range is given with this command, the module will set it’s output voltage to the nominal value (as if VOUT_TRIM had been set to 0), assert SMBALRT#, set the CML bit in STATUS_BYTE and the invalid data bit in STATUS_CML. REF OUT VRTrim RTrimV 20000 RTrim RTrimLOOP SCALE VOUT 20000 _ _ ) ( 2 _ TRIM VOUT V offset OUT
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 44. OUTPUT VOLTAGE MARGINING USING THE PMBUS The module can also have its output voltage margined via PMBus commands. The command VOUT_MARGIN_HIGH sets the margin high voltage, while the command VOUT_MARGIN_LOW sets the margin low voltage. Both the VOUT_MARGIN_HIGH and VOUT_MARGIN_LOW commands use the “Linear” mode with the exponent fixed at –10 (decimal). Two bytes are used for the mantissa with the upper bit [7] of the high byte fixed at 0. The actual margined output voltage is a combination of the VOUT_MARGIN_HIGH or VOUT_MARGIN_LOW and the VOUT_TRIM values as shown below: Note that the sum of the margin and trim voltages cannot be outside the ±25% window around the nominal output voltage. The data associated with VOUT_MARGIN_HIGH and VOUT_MARGIN_LOW can be stored to non-volatile memory using the STORE_DEFAULT_ALL command. The module is commanded to go to the margined high or low voltages using the OPERATION command. Bits [5:2] are used to enable margining as follows: 00XX : Margin Off 0101 : Margin Low (Ignore Fault) 0110 : Margin Low (Act on Fault) 1001 : Margin High (Ignore Fault) 1010 : Margin High (Act on Fault) 45. PMBUS ADJUSTABLE OVERCURRENT WARNING The SLDM-06D1Ax module can provide an overcurrent warning via the PMBus. The threshold for the overcurrent warning can be set using the parameter IOUT_OC_WARN_LIMIT. This command uses the “Linear” data format with a two byte data word where the upper five bits [7:3] of the high byte represent the exponent and the remaining three bits of the high byte [2:0] and the eight bits in the low byte represent the mantissa. The exponent is fixed at –1 (decimal). The upper six bits of the mantissa are fixed at 0 while the lower five bits are programmable with a default value of 7A. The resolution of this warning limit is 500mA. The value of the IOUT_OC_WARN_LIMIT can be stored to non-volatile memory using the STORE_DEFAULT_ALL command. 46. TEMPERATURE STATUS VIA PMBUS The SLDM-06D1Ax module can provide information related to temperature of the module through the STATUS_TEMPERATURE command. The command returns information about whether the pre-set over temperature fault threshold and/or the warning threshold have been exceeded. ) ( 2 ) _ _ _ ( TRIM VOUT HIGH MARGIN VOUT V MH OUT ) ( 2 ) _ _ _ ( TRIM VOUT LOW MARGIN VOUT V ML OUT
tech.support@psbel.com belpowersolutions.com 47. PMBUS ADJUSTABLE OUTPUT OVER AND UNDER VOLTAGE PROTECTION The module has output over and under voltage protection capability. The PMBus command VOUT_OV_FAULT_LIMIT is used to set the output over voltage threshold from four possible values: 108%, 110%, 112% or 115% of the commanded output voltage. The command VOUT_UV_FAULT_LIMIT sets the threshold that causes an output under voltage fault and can also be selected from four possible values: 92%, 90%, 88% or 85%. The default values are 112% and 88% of commanded output voltage. Both commands use two data bytes formatted as two’s complement binary integers. The “Linear” mode is used with the exponent fixed to –10 (decimal) and the effective over or under voltage trip points given by: Values within the supported range for over and undervoltage detection thresholds will be set to the nearest fixed percentage. Note that the correct value for VOUT_SCALE_LOOP must be set in the module for the correct over or under voltage trip points to be calculated. In addition to adjustable output voltage protection, the 6A Digital module can also be programmed for the response to the fault. The VOUT_OV_FAULT RESPONSE and VOUT_UV_FAULT_RESPONSE commands specify the response to the fault. Both these commands use a single data byte with the possible options as shown below. Continue operation without interruption (Bits [7:6] = 00, Bits [5:3] = xxx). Continue for four switching cycles and then shut down if the fault is still present, followed by no restart or continuous restart (Bits [7:6] = 01, Bits [5:3] = 000 means no restart, Bits [5:3] = 111 means continuous restart). Immediate shut down followed by no restart or continuous restart (Bits [7:6] = 10, Bits [5:3] = 000 means no restart, Bits [5:3] = 111 means continuous restart). Module output is disabled when the fault is present and the output is enabled when the fault no longer exists (Bits [7:6] = 11, Bits [5:3] = xxx). Note: that separate response choices are possible for output over voltage or under voltage faults. 48. PMBUS ADJUSTABLE INPUT UNDERVOLTAGE LOCKOUT The SLDM-06D1Ax module allows adjustment of the input under voltage lockout and hysteresis. The command VIN_ON allows setting the input voltage turn on threshold, while the VIN_OFF command sets the input voltage turn off threshold. For the VIN_ON command, possible values are either command, they will be mapped to the closest of the allowed values. VIN_ON must be set higher than VINPMBUS _OFF. Attempting to write either VIN_ON lower than VIN_OFF or VIN_OFF higher than VIN_ON results in the new value being rejected, SMBALERT being asserted along with the CML bit in STATUS_BYTE and the invalid data bit in STATUS_CML. Both the VIN_ON and VIN_OFF commands use the “Linear” format with two data bytes. The upper five bits represent the exponent (fixed at -2) and the remaining 11 bits represent the mantissa. For the mantissa, the four most significant bits are fixed at 0. ) _ ( ) _ ( 2 ) _ _ _ ( 2 ) _ _ _ ( LIMIT FAULT UV VOUT V LIMIT FAULT OV VOUT V REQ UV OUT REQ OV OUT
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 49. POWER GOOD The SLDM-06D1Ax module provides a Power Good (PGOOD) signal that is implemented with an open-drain output to indicate that the output voltage is within the regulation limits of the power module. The PGOOD signal will be de-asserted to a low state if any condition such as overtemperature, overcurrent or loss of regulation occurs that would result in the output voltage going outside the specified thresholds. The PGOOD thresholds are user selectable via the PMBus (the default values are as shown in the Feature Specifications Section). Each threshold is set up symmetrically above and below the nominal value. The POWER_GOOD_ON command sets the output voltage level above which PGOOD is asserted (lower threshold). For example, with a 1.2V nominal output voltage, the POWER_GOOD_ON threshold can set the lower threshold to The POWER_GOOD_OFF command sets the level below which the PGOOD command is de-asserted. This command also sets two thresholds symmetrically placed around the nominal output voltage. Normally, the POWER_GOOD_ON threshold is set higher than the POWER_GOOD_OFF threshold. Both POWER_GOOD_ON and POWER_GOOD_OFF commands use the “Linear” format with the exponent fixed at –10 (decimal). The two thresholds are given by Both commands use two data bytes with bit [7] of the high byte fixed at 0, while the remaining bits are r/w and used to set the mantissa using two’s complement representation. Both commands also use the VOUT_SCALE_LOOP parameter so it must be set correctly. The default value of POWER_GOOD_ON is set at 1.1035V and that of the POWER_GOOD_OFF is set at 1.08V. The values associated with these commands can be stored in non-volatile memory using the STORE_DEFAULT_ALL command. The PGOOD terminal can be connected through a pullup resistor(suggested value 100 K ) to a source of 5VDC or lower. 50. MEASURREMENT OF OUTPUT CURRENT, OUTPUT VOLTAGE AND INPUT VOLTAGE The SLDM-06D1Ax module is capable of measuring key module parameters such as output current and voltage and input voltage and providing this information through the PMBus interface. Roughly every 200μs, the module makes 16 measurements each of output current, voltage and input voltage. Average values of of these 16 measurements are then calculated and placed in the appropriate registers. The values in the registers can then be read using the PMBus interface. ) _ ( ) _ ( 2 ) _ _ ( 2 ) _ _ ( OFF GOOD POWER V ON GOOD POWER V OFF PGOOD OUT ON PGOOD OUT
tech.support@psbel.com belpowersolutions.com 51. MEASURING OUTPUT CURRENT USING THE PMBUS The module measures current by using the inductor winding resistance as a current sense element. The inductor winding resistance is then the current gain factor used to scale the measured voltage into a current reading. This gain factor is the argument of the IOUT_CAL_GAIN command, and consists of two bytes in the linear data format. The exponent uses the upper five bits [7:3] of the high data byte in two-s complement format and is fixed at –15 (decimal). The remaining 11 bits in two’s complement binary format represent the mantissa. The current measurement accuracy is also improved by each module being calibrated during manufacture with the offset in the current reading. The IOUT_CAL_OFFSET command is used to store and read the current offset. The argument for this command consists of two bytes composed of a 5-bit exponent (fixed at -4d) and a 11-bit mantissa. This command has a resolution of 62.5mA and a range of -4000mA to +3937.5mA. During manufacture, each module is calibrated by measuring and storing the current gain factor and offset into non-volatile storage. The READ_IOUT command provides module average output current information. This command only supports positive or current sourced from the module. If the converter is sinking current a reading of 0 is provided. The READ_IOUT command returns two bytes of data in the linear data format. The exponent uses the upper five bits [7:3] of the high data byte in two-s complement format and is fixed at –4 (decimal). The remaining 11 bits in two’s complement binary format represent the mantissa with the 11th bit fixed at 0 since only positive numbers are considered valid. Note that the current reading provided by the module is not corrected for temperature. The temperature corrected current reading for module temperature TModule can be estimated using the following equation where IOUT_CORR is the temperature corrected value of the current measurement, IREAD_OUT is the module current measurement value, TIND is the temperature of the inductor winding on the module. Since it may be difficult to measure TIND, it may be approximated by an estimate of the module temperature. 52. Measuring Output Voltage Using the PMBus The SLDM-06D1Ax module can provide output voltage information using the READ_VOUT command. The command returns two bytes of data all representing the mantissa while the exponent is fixed at -10 (decimal). During manufacture of the module, offset and gain correction values are written into the non-volatile memory of the module. The command VOUT_CAL_OFFSET can be used to read and/or write the offset (two bytes consisting of a 16-bit mantissa in two’s complement format) while the exponent is always fixed at -10 (decimal). The allowed range for this offset correction is -125 to 124mV. The command VOUT_CAL_GAIN can be used to read and/or write the gain correction - two bytes consisting of a five-bit exponent (fixed at -8) and a 11-bit mantissa. The range of this correction factor is -0.125V to +0.121V, with a resolution of 0.004V. The corrected output voltage reading is then given by: 53. MEASURING INPPUT VOLTAGE USING THE PMBUS The SLDM-06D1Ax module can provide output voltage information using the READ_VIN command. The command returns two bytes of data in the linear format. The upper five bits [7:3] of the high data form the two’s complement representation of the mantissa which is fixed at –5 (decimal). The remaining 11 bits are used for two’s complement representation of the mantissa, with the 11th bit fixed at zero since only positive numbers are valid. During module manufacture, offset and gain correction values are written into the non-volatile memory of the module. The command VIN_CAL_OFFSET can be used to read and/or write the offset - two bytes consisting of a five-bit exponent (fixed at -5) and a11-bit mantissa in two’s complement format. The allowed range for this offset correction is -2 to 1.968V, and the resolution is 32mV. The command VIN_CAL_GAIN can be used to read and/or write the gain correction - two bytes consisting of a five-bit exponent (fixed at -8) and a 11-bit mantissa. The range of this correction factor is -0.125V to +0.121V with a resolution of 0.004V. The corrected output voltage reading is then given by: OFFSET CAL VOUT GAIN CAL VOUT Initial V Final V OUT OUT _ _ )] _ _ 1 ( ) ( [ ) ( OFFSET CAL VIN GAIN CAL VIN Initial V Final V IN IN _ _ )] _ _ 1 ( ) ( [ ) (
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 54. READING THE STATUS OF THE MODULE USING THE PMBUS The SLDM-06D1Ax module supports a number of status information commands implemented in PMBus. However, not all features are supported in these commands. A 1 in the bit position indicates the fault that is flagged. STATUS_BYTE : Returns one byte of information with a summary of the most critical device faults. Bit Position Flag Default Value X OFF VOUT Overvoltage IOUT Overcurrent VIN Undervoltage Temperature CML (Comm. Memory Fault) None of the above STATUS_WORD : Returns two bytes of information with a summary of the module’s fault/warning conditions. Low Byte Bit Position Flag Default Value X OFF VOUT Overvoltage IOUT Overcurrent VIN Undervoltage Temperature CML (Comm. Memory Fault) None of the above High Byte Bit Position Flag Default Value VOUT fault or warning IOUT fault or warning X X POWER_GOOD# (is negated) X X X
tech.support@psbel.com belpowersolutions.com READING THE STATUS OF THE MODULE USING THE PMBUS(CONTINIUED) STATUS_VOUT : Returns one byte of information relating to the status of the module’s output voltage related faults. Bit Position Flag Default Value VOUT OV Fault X X VOUT UV Fault X X X X STATUS_IOUT : Returns one byte of information relating to the status of the module’s output voltage related faults. Bit Position Flag Default Value IOUT OC Fault X IOUT OC Warning X X X X X STATUS_TEMPERATURE : Returns one byte of information relating to the status of the module’s temperature related faults. Bit Position Flag Default Value OT Fault OT Warning X X X X X X STATUS_CML : Returns one byte of information relating to the status of the module’s communication related faults. Bit Position Flag Default Value Invalid/Unsupported Command Invalid/Unsupported Command Packet Error Check Failed X X X Other Communication Fault X
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC READING THE STATUS OF THE MODULE USING THE PMBUS(CONTINIUED) MFR_VIN_MIN : Returns minimum input voltage as two data bytes of information in Linear format (upper five bits are exponent – fixed at -2, and lower 11 bits are mantissa in two’s complement format – fixed at 12) MFR_VOUT_MIN : Returns minimum output voltage as two data bytes of information in Linear format (upper five bits are exponent – fixed at -10, and lower 11 bits are mantissa in two’s complement format – fixed at 614) MFR_SPECIFIC_00 : Returns information related to the type of module and revision number. Bits [7:2] in the Low Byte indicate the module type (000101 corresponds to the SLDM-06D1Ax series of module), while bits [7:3] indicate the revision number of the module. Low Byte Bit Position Flag Default Value 7:2 Module Name 000101 1:0 Reserved High Byte Bit Position Flag Default Value 7:3 Module Revision Number None 2:0 Reserved 000
tech.support@psbel.com belpowersolutions.com 55. SUMMARY OF SUPPORTED PMBUS COMMANDS Please refer to the PMBus 1.1 specification for more details of these commands. Table 6
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC SUMMARY OF SUPPORTED PMBUS COMMANDS(CONTINIUED)
tech.support@psbel.com belpowersolutions.com SUMMARY OF SUPPORTED PMBUS COMMANDS(CONTINIUED)
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC SUMMARY OF SUPPORTED PMBUS COMMANDS(CONTINIUED)
tech.support@psbel.com belpowersolutions.com SUMMARY OF SUPPORTED PMBUS COMMANDS(CONTINIUED)
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC SUMMARY OF SUPPORTED PMBUS COMMANDS(CONTINIUED)
tech.support@psbel.com belpowersolutions.com SUMMARY OF SUPPORTED PMBUS COMMANDS(CONTINIUED)
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC SUMMARY OF SUPPORTED PMBUS COMMANDS(CONTINIUED)
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 57. EXAMPLE APPLICATION CIRCUIT Requirements: Vin: 12V Vout: 1.8V Iout: 4.5A max., worst case load transient is from 3A to 4.5A Vout: 1.5% of Vout (27mV) for worst case load transient Vin, ripple 1.5% of Vin (180mV, p-p) CI1 Decoupling cap - 1x0.047 F/16V ceramic capacitor (e.g. Murata LLL185R71C473MA01) CI2 2x22 F/16V ceramic capacitor (e.g. Murata GRM32ER61C226KE20) CI3 470 F/16V bulk electrolytic CO1 Decoupling cap - 1x0.047 F/16V ceramic capacitor (e.g. Murata LLL185R71C473MA01) + 0.1uF/16V 0402size ceramic capacitor CO2 4x47 F/6.3V ceramic capacitor CO3 - CTune 2200pF ceramic capacitor (can be 1206, 0805 or 0603 size) RTune 300 ΩSMT resistor (can be 1206, 0805 or 0603 size) RTrim 10k SMT resistor (can be 1206, 0805 or 0603 size, recommended tolerance of 0.1%) Note: The DATA, CLK and SMBALRT pins do not have any pull-up resistors inside the module. Typically, the SMBus master controller will have the pull-up resistors as well as provide the driving source for these signals. RADDR0 DATA SEQ VS RADDR1 GND Vin+ CI3 CO3 ADDR0 VOUT VS+ GND TRIM CTUNE RTUNE RTrim VIN CO1 CI1 Vout+ ON/OFF SEQ SMBALRT# MODULE PGOOD ADDR1 SIG_GND SYNC CI2 CO2
tech.support@psbel.com belpowersolutions.com 58. ME CHANICAL DIMENSIONS Dimensions are in millimeters and (inches).
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC MECHANICAL DIMENSIONS (continued) Recommended Pad Layout PIN CONNECTIONS Dimensions are in millimeters and (inches). Note: This module is recommended and compatible with Pb-Free Reflow Soldering and must be soldered using a reflow profile with a peak temperature of no more than 260 ºC for less than 5 seconds. PIN FUNCTION ON/OFF VIN SEQ GND TRIM VOUT VS+ VS- PG SYNC CLK DATA SMBALERT SIG_GND ADDR1 ADDR0
tech.support@psbel.com belpowersolutions.com 59. PACKAGING DETAILS The SLDM-06D1Ax modules are supplied in tape & reel as standard. All Dimensions are in millimeters and (in inches). Reel Dimensions: Outside Dimensions: 330.2 mm (13.00) Inside Dimensions: 177.8 mm (7.00”) Tape Width: 44.00 mm (1.732”)
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC 60. SURFACE MOUNT INFORMATION Pick and Place The SLDM-06D1Ax modules use an open frame construction and are designed for a fully automated assembly process. The modules are fitted with a label designed to provide a large surface area for pick and place operations. The label meets all the requirements for surface mount processing, as well as safety standards, and is able to withstand reflow temperatures of up to 300oC. The label also carries product information such as product code, serial number and the location of manufacture. Nozzle Recommendations The module weight has been kept to a minimum by using open frame construction. Variables such as nozzle size, tip style, vacuum pressure and placement speed should be considered to optimize this process. The minimum recommended inside nozzle diameter for reliable operation is 3mm. The maximum nozzle outer diameter, which will safely fit within the allowable component spacing, is 7 mm. Bottom Side / First Side Assembly The modules are lead-free (Pb-free) and RoHS compliant and fully compatible in a Pb-free soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Lead Free Soldering The modules are lead-free (Pb-free) and RoHS compliant and fully compatible in a Pb-free soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Pb-free Reflow Profile Power Systems will comply with J-STD-020 Rev. D (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pb-free solder profiles and MSL classification procedures. This standard provides a recommended forced-air-convection reflow profile based on the volume and thickness of the package (table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Fig. 50. Soldering outside of the recommended profile requires testing to verify results and performance. MSL Rating The SLDM-06D1Ax modules have a MSL rating of 2A.
tech.support@psbel.com belpowersolutions.com SURFACE MOUNT INFORMATION(CONTINIUED) Storage and Handling The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD- 033 Rev. B (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices). Moisture barrier bags (MBB) with desiccant are required for MSL ratings of 2 or greater. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of 30°C and 60% relative humidity varies according to the MSL rating (see J-STD-033A). The shelf life for dry packed SMT packages will be a minimum of 12 months from the bag seal date, when stored at the following conditions: < 40° C, < 90% relative humidity. Figure51 Recommended linear reflow profile using Sn/Ag/Cu solder. Post Solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Board Mounted Power Modules: Soldering and Cleaning Application Note (AN04-001).
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection Rev. AC For more information on these products consult: tech.support@psbel.com NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.