SLB65 ADVANCEDENERGY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 6

Technical content

©2022 Advanced Energy Industries, Inc. SL POWER SLB65 SERIES

65 Watts Single Output

Medical & Industrial Grade Total Power

65 Watts

# of Outputs Single AT A GLANCEAdvanced Energy’s SL Power SLB65 medically-approved AC-DC power supplies are available with a nominal main output of 5 V, 12 V, 15 V, 18 V, 24 V, or 48 V. SLB65 power supplies provide up to 65 Watts convection. All models have output overvoltage, short circuit and overload protection and a small 2 x 3 x 1.2 inch form factor. SPECIAL FEATURES  65 Watts Convection  Small 2” x 3” x 1.2” Form Factor  Universal Input 80 to 264 VAC  For 1U Applications  2 x MOPP Isolation  Meets Heavy Industrial/4th Edition EMC  -20 O C To 70 O C Operating Temperature Range  3 Years Warranty SAFETY  UL/CSA/IEC/IEC60601-1, 3rd. Ed.  UL/CSA/IEC62368-1

2 advancedenergy.com SLB65 ELECTRICAL SPECIFICATIONS Input Input ra nge 80 to 264 VAC, 47 to 63 Hz, 1Ø Input current 1.0 A max at 230 VAC Inrush current 85 A max., cold start @ 264 VAC input, 25 O C Input fuses 3.15 A, 250 VAC Leakage current Earth Patient <500 μA @ 264 VAC, 60 Hz, NC <100 μA @ 264 VAC, 60 Hz Efficiency (typ. @ 25 O C ) SLB65S12x, SLB65S15x SLB65S18x SLB65S24x SLB65S48x 89% @ 230 VAC, 86.5% @ 115 VAC, full load 89% @ 230 VAC, 87.0% @ 115 VAC, full load 89% @ 230 VAC, 87.0% @ 115 VAC, full load 88% @ 230 VAC, 88% @ 115 VAC, full load Isolation voltage Input/Ground: 1500 VAC (1 MOPP) Input/Output: 4000 VAC (2 MOPP) Output/Ground: 1500 VAC Output Maximum power Max of 65 Watts for convection cooled. See "Ordering information" section. Ripple and noise 0.5% RMS, 1% to 1.5% pk-pk for all models. (20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors) Total regulation ±2% ( Maximum deviation from nominal voltage for all loading conditions) Minimum load Not required Overshoot <5% overshoot at turn-on, <5% overshoot at turn-off, under all conditions Transient response 500 μs response time for return to within 0.5% of final value for a 50% load step change, ∆i/∆t<0.2 A/μs. Max. voltage deviation is ±3.5%, @ 25 O C Hold-up time 12 ms typical from loss of AC input at 115 VAC Turn on time <2 s @ 115 VAC (<3 s for 12 V output model) Cooling Convection (65 W Output) Reliability MTBF >500K hours, 25°C, full rated load (Calculation is done based on Telcordia reports ) Warranty 3 years Protection Overvoltage protection 115% to 130% of nominal output voltage. Requires AC recycle to reset. Latch mode. Short circuit protection Short across the output terminals will not cause damage to the unit. Hiccup mode. Thermal protection Will shutdown upon an over temperature condition. Auto-recovery mode. Overload protection 120% to 180% of rated output current value. Hiccup mode.

advancedenergy.com 3 SLB65 DERATING CURVES EMI/EMC COMPLIANCE Conducted emissions EN55011/22 Class B; FCC Part 15, EN55015/CISPR15:2013, CISPR22 2006 Class B, CISPR32 Class B, FCC Part 15.107, Class B: at 115 and 230 Vac Radiated emissions EN55011/22 Class A; FCC Part 15, CISPR15 radiated EN55032/CISPR22 Class B, CISPR32 Class B, FCC Part 15.109, Class B: at 115 and 230 Vac Harmonic current emissions EN61000-3-2, Class A, B, C & D Voltage fluctuations & flicker IEC61000-3-3 Electro static discharge immunity EN61000-4-2, Level 4: 8kV contact, 15kV air, Criteria A Radiated RF fields susceptibility EN61000-4-3, Level 3 (3V/m), Criteria A. EN55032/EN61000-4-3, 10V/m, 80MHz to 2.7GHz, 80% AM at 1kHz, IEC60601-1-2, 4th Edition, Table 4 100Khz rep rate, 40A, Criteria A, IEC60601-1-2, 4th Edition, Table 5 Surge susceptibility EN61000-4-5, Installation Class 3 (1kV diff. mode, 2kV common mode), Criteria A, EN55024/IEC61000-4-5, Level 4, ±2kV DM, ±4kV CM, Criteria A, Surpasses IEC60601-1-2, 4th Edition requirements. Conducted RF susceptibility EN61000-4-6, Level 3 (3Vrms), Criteria A, EN55032/IEC61000-4-6, 3V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz, IEC60601-1-2, 4th Edition, Table 5. Rated power frequency magnetic fields test EN61000-4-8, Level 3 (3A/m), Criteria A, EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz, IEC60601-1-2, 4th Edition, Table 4 Voltage Sags & Surges EN61000-4-11, 95% dip/0.5 cycle (Criteria A), 60%/5 cycles (Criteria B), 30%/25 cycles (Criteria A), Loading is 70% of 100W with 100VAC EN55024/IEC/EN61000-4-11: --100% dip for 20 ms, 0°, Criteria A --100% dip for 5000 ms (250/300 cycles), Criteria B --60% dip for 100 ms, Criteria B --30% dip for 500 ms, Criteria A IEC60601-1-2, 4th Edition, Table 5 Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are decoded as following: A. Normal performance during and after the test B. Temporary degradation, self-recoverable C. Temporary degradation, operator intervention required to recover the operation D. Permanent damage

4 advancedenergy.com SLB65

ORDERING INFORMATION

Threshold Ripple & Noise SLB65S18x 18 V ±2% 21.0 ± 3.0V 0.5%RMS, 1.0% pk-pk Notes: Replace the "x" at the end of the model number with "C" for class II (ungrounded) input or replace with "K" for class I (grounded) input. ENVIRONMENTAL SPECIFICATIONS Vibration Random vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4-1, 1 hr in each of three axes Shock Non-operating: Half-sine, 40 gpk, 10ms, 3 axes, 6 shocks total Cooling Convection Operating temperature -20°C to +70°C Temperature derating 40% derating at 70°C Storage temperature -40°C to +85°C Altitude Operating: 500 to 5,000 m. Non-operating: 500 to 40,000 ft Relative humidity 5% to 95%, non-condensing PIN ASSIGNMENTS SAFETY UL/CSA/Demko EN/CSA/UL/IEC 60601-1 3rd edition BF Rated & EN62368-1 CB report Yes Isolation type Double/Reinforced between input and output Connector SLB65 Mating Connector Mating Pin J1 (Input connector) PIN 1 AC Line AMP: 640250-3 AMP: 640252-2PIN 2 SPARE PIN 3 AC Neutral J2 (Output connector) PIN 1 +Vo AMP: 640250-4 AMP: 640252-2 PIN 2 +Vo PIN 3 RTN PIN 4 RTN G1 (Ground) - - Ring type terminal or similar

3.3 A 60 W

advancedenergy.com 5 SLB65 MECHANICAL DRAWING Notes: 1. All dimensions in inches (mm).

ENG-SLB65-12.1 8.23 For international contact information, visit advancedenergy .com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. TRUST Specifications are subject to change without notice. Not responsible for errors or omissions. ©2023 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, and AE® are U.S. trademarks of Advanced Energy Industries, Inc.