SL6140 MITEL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

Figure 2 Pin Connections Diagram (top view) MP8

Electrical Characteristics

Tamb = 25°C, VCC = 12V +5%, VIN = 1mVRMS, Frequency = 6MHz, Load (R L) = 10KOHms, RAGC = 22KOHm These characteristics are guaranteed over the following conditions (unless otherwise stated) OUTPUT INPUT +VCC GROUND INPUT AGC INPUT OUTPUT GROUND 5,6,7 5,6 (sum) 5,6 5,6 5,6 5,6 5,6 5,6 5,6 1.0 400 3.5 3.5 mA mA mA dB dB dB dB MHz V p-p V p-p dB Supply current Output stage current Output current matching (magnitude of difference of output currents) AGC range Voltage gain (single ended) Bandwidth (-3dB) Maximum output level (single ended) 0dB AGC -30dB AGC Noise figure No input signal No input signal See Figure 4 & Note 1 (VAGC = 0V to 10V) R L = 1kΩ See Figure 5 & Note 1 Tuned input and output RL = 50Ω RL = 1kΩ See Figure 5 RL = 50Ω Note 1 RL = 1kΩ. Note 1 Test CCT Figure 13 MaxTypMin Pin UnitsCharacteristic Conditions Value Note. 1 Guaranteed but not tested. Absolute Maximum Ratings Supply voltage, VCC +18V Input voltage (differential) +5V AGC supply V CC Storage temperature -55 °C to +150°C Operating temperature range SL6140 MP -40 °C to +85°C at 200mW Chip operating temperature SL6140 MP +150 °C Thermal Resistance Chip-to-ambient SL6140 MP 163 °C/W Chip-to-case SL6140 MP 57 °C/W

Figure 3 Full Circuit Diagram of SL6140 2.1k1.1k1.1k 5k5k 5.6k 1.4k 7k 12.1k 470 X 2 1.9k 200 2.8k 2.8k200 200 180 470470 180 SUBSTRATE GROUND OUTPUT OUTPUT VCC AGC I/P INPUT INPUT

M Mitel (design) and ST -BUS are registered trademarks of MITEL Corporation Mitel Semiconductor is an ISO 9001 Registered Company Copyright 1999 MITEL Corporation All Rights Reserved Printed in CANADA TECHNICAL DOCUMEN TATION - NO T FOR RESALE World Headquarters - Canada Tel: +1 (613) 592 2122 Fax: +1 (613) 592 6909 North America Asia/Pacific Europe, Middle East, Tel: +1 (770) 486 0194 Tel: +65 333 6193 and Africa (EMEA) Fax: +1 (770) 631 8213 Fax: +65 333 6192 Tel: +44 (0) 1793 518528 Fax: +44 (0) 1793 518581 http://www.mitelsemi.com Information relating to products and services furnished herein by Mitel Corporation or its subsidiaries (collectively “Mitel”) is believed to be reliable. However, Mitel assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Mitel or licensed from third parties by Mitel, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Mitel, or non-Mitel furnished goods or services may infringe patents or other intellectual property rights owned by Mitel. This publication is issued to provide information only and (unless agreed by Mitel in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Mitel without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Mitel’s conditions of sale which are available on request.