325 www.littelfuse.com GDT SHOWING SEATING PLANE FOR SL1002AxxxSM 6.0 ±0.2 6.2 ±0.2 SL1002AxxxC 5.0 1.3 RECOMMENDED PAD LAYOUT 6.2 ±0.2 SL1002AxxxSM 3.5 4.3±0.3 0.8 4.2±0.2 SL1002AxxxSM All dimensions in mm The Broadband Optimized™ SL1002 series has been especially developed for use in broadband equipment. Unique design features offer high levels of performance on fast rising transients in the domain of 100V/µS to 1KV/µS, which are those most likely from induced Lightning disturbances. These devices have Ultra low capacitance (typically 1.2pF or less) and present insignificant signal losses up to 1.5GHz. These devices are extremely robust and are able to divert a 5000A pulse without destruction. For AC Power Cross of long duration, overcurrent protection is recommended.
FEATURES
- RoHS compliant and Lead-free
- Ultra Low Insertion Loss Surface mountable
- 5KA surge capability tested with 8/20µS pulse as defined by IEC 61000-4-5
- Excellent response to fast rising transients.
- Can be used to meet Telcordia GR1089 without series resistance
- 10/700 6KV capability, as per ITUT k.21, enhanced test level
- 2000 Amp 2/10µS surge rating
- Meets FCC part 68 10/160µs waveform, 200A test and 10/560µs waveform 100A test. Applications:
- Broadband equipment.
- ADSL equipment.
- XDSL equipment.
- Satellite and CATV equipment.
- General telecom equipment. Mechanical Specifications: Weight: 0.63g (0.022 oz.) Materials: Electrode Base: Nickel Iron Alloy Electrode Plating: Bright Sn Body: Ceramic Device Marking: ‘LF’ logo, Voltage and date code PbRoHS Greentube™ SL1002A Series Gas Plasma Arrester High Performance Beta Range
326www.littelfuse.com 8GAS DISCHARGE TUBES High Performance Beta Range LITTELFUSE 2 TERMINAL MINI ARRESTER SERIES TOTALLY NON-RADIOACTIVE, UL RECOGNIZED Notes: 1. Comparable to the silicon measurement Switching Voltage (V s) 2. 10 shots, AC 60Hz, 1µs duration 3. 10 shots, 8/20µs waveform per IEC 61000-4-5 4. Measured at 100V, except 90VDC devices wich are measured at 50V 5. Tested according to ITU-T Rec. K.12 Greentube™ SL1002A Series Gas Plasma Arrester Voltage (V) Time (ns) 0 200 400 600 800 1000 1200 Max dynamic breakover voltage Hold-over voltage On-State voltage Voltage vs Time Characteristic ®PbRoHS SL1002A090 70 120 360 700 5 5 2 2 100 50 20 SL1002A230 184 276 400 500 5 5 2 2 100 135 20 SL1002A250 200 300 400 500 5 5 2 2 100 135 20 SL1002A260 210 310 400 500 5 5 2 2 100 135 20 SL1002A350 280 420 500 600 5 5 2 2 100 135 20 SL1002A600 480 720 800 900 5 5 2 2 100 135 20 DC Breakover MAX Dynamic Max NominalVoltage @100 V/s Breakover AC Repetitive MAX Single Max On-stateVolts Voltage 1 Discharge Impulse Impulse Current Leakage Holdover Voltage Part 100 V/ µs 1kV/µs Current 2 Current3 2/10 µs 2/350 µs Current 4 Voltage5 @1A Number* MIN MAX Volts Volts Amps kAmps kAmps kAmps nAmps Volts Volts *Max capacitance is 1.2 pF, measured at 1 MHz, zero volt bias @ 1.0 GHz = 0.01 dB @1.4GHz = 0.1dB @1.8 GHz = 0.53 dB @2.1 GHz = 0.81 dB @2.45 GHz= 1dB @2.8 GHz = 1.2 dB @3.1 GHz = 1.5dB @3.5 GHz = 2.1 dB Typical Insertion Loss