BML06HC BALLUFF | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Magnetically Coded Sensors BML SL1-ALZ0-U1ZZ-AU1L-S284 Order Code: BML06HC Internet www.balluff.com eCl@ss 9.1: 27-27-07-05 Subject to change without notice: 279063 ETIM 6.0: EC002544 BML06HC_0.4_2021-05-21 1) not included in scope of delivery, 2) Distance to tape, 3) Tape, 4) LED function indicator, 5) Active measurement surface Basic features Additional features 01 Real-time capable Additional features 02 Analog, sin/cos Application linear/rotary motion Approval/Conformity cURus CE EAC WEEE Measuring principle absolute measuring system Series SL1 Display/Operation Error value 0x7FFFFFFF Function indicator Green LED LED red Electrical connection Connection Connector, M12x1-Male, 12-pin Connection version axial Polarity reversal protected yes Electrical data Current consumption max. at 24 V DC 70 mA Hysteresis H max. 1 µm Operating voltage Ub 18...30 VDC Output value Position in µm Overvoltage protection no PD cycle min., 1.1 master 1 ms Periods 2 mm Power consumption ≤ 1.4 W (no load) Switch-on delay max. 100 ms Voltage-proof up to (GND to housing) 500 V DC
Magnetically Coded Sensors BML SL1-ALZ0-U1ZZ-AU1L-S284 Order Code: BML06HC Internet www.balluff.com eCl@ss 9.1: 27-27-07-05 Subject to change without notice: 279063 ETIM 6.0: EC002544 BML06HC_0.4_2021-05-21 Environmental conditions Altitude max. 2000 m Ambient temperature -10...70 °C EN 55016-2-3, Radiation Industrial areas EN 60068-2-27, Continuous shock 150 g, 2 ms EN 60068-2-27, Shock 100 g, 6 ms EN 60068-2-6, Vibration 20 g, 10…2000 Hz EN 60068-2-64, Noise 20 g, 5…2000 Hz EN 61000-4-2, ESD Severity Level 4 EN 61000-4-3, RFI Severity Level 3 EN 61000-4-4, Burst Severity Level 3 EN 61000-4-5, Surge Severity Level 2 EN 61000-4-6, High-frequency fields Severity Level 3 EN 61000-4-8 Magnetic fields Severity Level 5 Ext. magnetic fields max., in operation 1 mT (no effect) IP rating IEC 60529 (connector) IP67 Overall system temperature coefficient 10.5 ppm/K Relative humidity ≤ 90 %, non-condensing Storage temperature -25...85 °C Functional safety MTTF (40 °C) 149 a Material Housing material Die-cast zinc, nickel plated, Chrome-plated Housing material, surface protection nickel-plated Chrome-plated Mechanical data Diameter min. 400 mm Dimension 16 x 18.6 x 54 mm Lateral offset (Y) ±1.5 mm Mounting part Through-hole 4.3 mm Pitch max. ±0.5 ° Pole width 2 mm Procedure direction Lengthwise to tape Roll max. ±0.5 ° Tangential offset (X) max. ±1 mm Weight 50 g Yaw max. ± 1.0 ° Output/Interface Count direction rising Cycle time min. 1 ms Data format 32-bit signed Differential signals yes Error signal yes IO-Link version 1.1 Interface IO-Link 1.1 Analog Sin/Cos (1 Vpp) Interface coding Binary Preset configurable via IO-Link system parameters Process data, master – device 0 bytes Prozessdaten, Device – Master 4 bytes Real-time signals Analog, sin/cos Signal sequence A before B = rising Range/Distance Interpolation factor 2000 Measuring range 8190 mm Non-linearity of sensor head, max. ±5 µm Optimal read distance 0.4 mm Repeat accuracy ≤ 1 µm Resolution 1 µm Traverse speed max. 10 m/s
Magnetically Coded Sensors BML SL1-ALZ0-U1ZZ-AU1L-S284 Order Code: BML06HC Internet www.balluff.com eCl@ss 9.1: 27-27-07-05 Subject to change without notice: 279063 ETIM 6.0: EC002544 BML06HC_0.4_2021-05-21 Connector Drawings Wiring Diagrams