Figure 2. SKY65162-70LF Pinout Package Table 1. SKY65162-70LF Signal Descriptions
1 RF_IN RF input
2 GND Ground
3 RF_OUT RF output
4 GND Ground
over a frequency range of 400 to 3800 MHz. Figures 72 through 82 (3600 MHz).
Table 2. SKY65162-70LF Absolute Maximum Ratings1 at or below their nominal values. Exceeding any of the limits listed here may result in permanent damage to the device. ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD handling precautions should be used at all times. Table 3. SKY65162-70LF Recommended Operating Conditions Table 4. SKY65162-70LF Electrical Characteristics1 1 Performance shown in this table is verified by char acterization and is not guaranteed by production test.
Table 5. SKY65162-70LF Electrical Characteristics1 1 Performance shown in this table is verified by char acterization and is not guaranteed by production test.
Figure 3. Operating Current vs Output Power Over Temperature Figure 5. Gain vs Output Power Over Temperature Figure 7. OP1dB vs Frequency Over Temperature Figure 4. Gain vs Output Power Over Voltage
0.869 GHz
0.920 GHz
0.960 GHz
Figure 6. Gain vs Output Power Over Frequency Figure 8. OP1dB vs Frequency Over Voltage
Figure 9. Noise Figure vs Frequency Over Temperature Figure 11. Input Return Loss vs Frequency Over Temperature Figure 13. Small Signal Gain vs Frequency Over Voltage Figure 10. Noise Figure vs Frequency Over Voltage Figure 12. Small Signal Gain vs Frequency Over Temperature
0.915 GHz
Figure 14. OIP3 vs Output Power Over Frequency
Table 6. SKY65162-70LF Electrical Characteristics1 1 Performance is guaranteed only under the conditions listed in this table. 2 Verified by characterization; not tested in production. Figure 18. Operating Current vs Output Power Over Temperature Figure 20. Gain vs Output Power Over Temperature Figure 19. Gain vs Output Power Over Voltage
1.93 GHz
1.96 GHz
1.99 GHz
Figure 21. Gain vs Output Power Over Frequency
Figure 28. Small Signal Gain vs Frequency Over Voltage Figure 30. OIP3 vs Output Power Over Temperature Figure 32. ACPR vs Output Power Over Temperature Figure 29. OIP3 vs Output Power Over Frequency Figure 31. OIP3 vs Output Power Over Voltage Figure 33. ACPR vs Output Power Over Frequency
1930 MHz
1960 MHz
1990 MHz
Figure 34. ACLR vs Output Power Over Frequency Table 7. SKY65162-70LF Electrical Characteristics1 1 Performance shown in this table is verified by char acterization and is not guaranteed by production test. Figure 35. Operating Current vs Output Power Over Temperature Figure 36. Gain vs Output Power Over Voltage
Figure 37. Gain vs Output Power Over Temperature Figure 39. OP1dB vs Frequency Over Temperature Figure 41. Noise Figure vs Frequency Over Temperature
2.11 GHz
2.14 GHz
2.17 GHz
Figure 38. Gain vs Output Power Over Frequency Figure 40. OP1dB vs Frequency Over Voltage Figure 42. Noise Figure vs Frequency Over Voltage
Figure 43. Input Return Loss vs Frequency Over Temperature Figure 45. Small Signal Gain vs Frequency Over Voltage Figure 47. OIP3 vs Output Power Over Temperature Figure 44. Small Signal Gain vs Frequency Over Temperature Figure 46. OIP3 vs Output Power Over Frequency Figure 48. OIP3 vs Output Power Over Voltage
Figure 49. ACLR vs Output Power Over Frequency Table 8. SKY65162-70LF Electrical Characteristics1
54 Mbps, 3% EVM
1 Performance shown in this table is verified by char acterization and is not guaranteed by production test. Figure 50. Operating Current vs Output Power Over Temperature Figure 51. Gain vs Output Power Over Temperature
2.412 GHz
2.442 GHz
2.472 GHz
Figure 52. Gain vs Output Power Over Frequency Figure 54. OP1dB vs Frequency Over Temperature Figure 56. Noise Figure vs Frequency Over Temperature Figure 53. Gain vs Output Power Over Voltage Figure 55. OP1dB vs Frequency Over Voltage Figure 57. Noise Figure vs Frequency Over Voltage
Figure 58. Input Return Loss vs Frequency Over Temperature Figure 60. Small Signal Gain vs Frequency Over Voltage Figure 62. OIP3 vs Output Power Over Temperature Figure 59. Small Signal Gain vs Frequency Over Temperature Figure 61. OIP3 vs Output Power Over Frequency Figure 63. OIP3 vs Output Power Over Voltage
Figure 64. Gain vs Frequency Over Voltage
2412 MHz
2442 MHz
2462 MHz
Figure 66. EVM vs Output Power Over Frequency Figure 65. EVM vs Output Power Over Frequency Figure 67. Operating Current vs Output Power Over Voltage
Table 9. SKY65162-70LF Electrical Characteristics1 1 Performance shown in this table is verified by char acterization and is not guaranteed by production test.
2500 MHz
2600 MHz
2700 MHz
Figure 68. OIP3 vs POUT @ 2700 MHz Figure 70. Current vs POUT @ 2600 MHz Figure 69. Gain vs Frequency @ 2600 MHz Figure 71. Noise Figure vs Frequency @ 2600 MHz
Figure 76. Gain vs Frequency Figure 78. Noise Figure vs Frequency Figure 80. OIP3 vs Frequency
3400 MHz
3600 MHz
3800 MHz
Figure 77. Current vs Output Power Figure 79. P1dB vs Frequency Figure 81. OIP3 vs POUT
Figure 82. Gain vs POUT
characteristics are noted in Figure 85. Capacitors C7, C8, and C9 provide DC bias decoupling for VCC. Pins 1 and 3 are the RF input and output signals, respectively. DC and RF ground, respectively.
- Connect a 5.0 V supply to VCC. If available, enable the current
limiting function of the power supply to 400 mA.
- Connect a signal generator to the RF signal input port. Set it to
to the Evaluation Board but do NOT enable the RF signal.
- Connect a spectrum analyzer to the RF signal output port.
Board can be permanently damaged. must be followed regardless of final use or configuration.
- Paths to ground should be made as short as possible.
- The ground pad of the SKY65162-70LF power amplifier has
grounding layer are required. Table 11. The Evaluation Board is available in seven
Figure 83. Evaluation Board Assembly Drawing
Figure 84. Evaluation Board Layer Detail
Figure 85. Layer Detail Physical Characteristics
Figure 86. SKY65162-70LF Evaluation Board Schematic Table 11. SKY65162-70LF (SOT-89 Package) Evaluation Board Bill of Materials with EK#/Operating Frequency Breakdown
400 MHz 915 MHz 1960 MHz 2100 MHz 2400 MHz 2600 MHz 3600 MHz
dimensions are provided in Figure 88. part is subjected to high temperature during solder assembly. (MSL1) at 260 C. It can be used for lead or lead-free soldering. Note, Solder Reflow Information, document number 200164. done manually or in a production solder reflow environment. Figure 87. SKY65162-70LF Package Dimensions
- Carrier tapes must meet all requirements of Skyworks GP01-D233
procurement spec for tape and reel shipping.
- Carrier tape material: black conductive polycarbonate or polystyrene.
- Cover tape material: transparent conductive PSA.
Cover tape size: 9.2 mm width.
- Typical ESD surface resistivity must meet all ESD requirements of Skyworks specified in GP01-D233.
- Ao and Bo measurement point to be 0.30 mm from bottom pocket.
- All measurements are in millimeters.
- 10-sprocket hole pitch cumulative tolerance 0.2 mm.
Figure 88. SKY65162-70LF Tape and Reel Dimensions
DATA SHEET • SKY65162-70LF LINEAR PA Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201212K • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 22, 2018 29
Ordering Information
Part Number Product Description Evaluation Board Part Number SKY65162-70LF SKY65162-70LF: 400 to 3800 MHz Linear Power Amplifier SKY65162-70EK1 (400 MHz) SKY65162-70EK2 (915 MHz) SKY65162-70EK3 (1960 MHz) SKY65162-70EK4 (2100 MHz) SKY65162-70EK5 (2400 MHz) SKY65162-70EK6 (2600 MHz) SKY65162-70EK7 (3600 MHz) Copyright © 2010, 2011, 2013, 2016-2018 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.