SKY13384-350LF SKYWORKS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 12
Technical content
Table 1. SKY13384-350LF Signal Descriptions 1 RF4 RF output 4. A DC blocking capacitor is required. 9 RF2 RF output 2. A DC blocking capacitor is required.
2 GND Ground 10 GND Ground
3 GND Ground 11 GND Ground
4 RF3 RF output 3. A DC blocking capacitor is required. 12 RF1 RF output 1. A DC blocking capacitor is required.
5 GND Ground 13 GND Ground
6 VDD Supply voltage input 14 GND Ground
decoder is internally connected to a GaAs pHEMT RF switch. a high isolation path to the alternate port. applied to one of the control lines. The device must be turned off in the reverse order. illustrated in Figures 3 through 9. Table 2. SKY13384-350LF Absolute Maximum Ratings (Note 1) parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
DATA SHEET • SKY13384-350LF: SP4T SWITCH Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 201529C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 6, 2015 3
Table 3. SKY13384-350LF Electrical Specifications (Note 1)
1 MHz spacing
Note 1: Performance is guaranteed only under the conditions listed in this table. Note 2: Return loss in the insertion loss state is dependent on the value of DC blocking capacitors. Table 4. SKY13384-350LF Truth Table
1 V LOW V LOW RFC to RF1
2 V LOW V HIGH RFC to RF2
3 V HIGH V LOW RFC to RF3
4 V HIGH V HIGH RFC to RF4
Any state other than described in this Table places the switch into an undefined state.
increased to maintain return loss in the insertion loss state. due to limitations of on-chip capacitors. Figure 10. SKY13384-350LF Evaluation Board Schematic
Figure 11. SKY13384-350LF Evaluation Board Assembly Diagram
0.225 X 45o
Figure 12. SKY13384-350LF PCB Layout Footprint Figure 13. Typical Part Markings
0.15 C2X
0.10 M C A B
16 Places
All measurements are in millimeters. Dimensioning and tolerancing according to ASME Y14.5M-1994. Coplanarity applies to the exposed heat sink slug as well as the terminals.. Plating requirement per source control drawing (SCD) 2504. Exposed pads are matte tin plated.
0.05 M C
Figure 14. SKY13384-350LF 16-Pin QFN Package Dimensions
- Carrier tape: black conductive polystyrene, non-bakeable material.
- Cover tape material: transparent conductive HSA.
- Cover tape size: 9.20 mm width.
- All measurements are in millimeters.
Figure 15. SKY13384-350LF Tape and Reel Dimensions
DATA SHEET • SKY13384-350LF: SP4T SWITCH Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 12 November 6, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201529C
Ordering Information
Model Name Manufacturing Part Number Evaluation Board Part Number SKY13384-350LF SP4T Switch SKY13384-350LF SKY13384-350LF-EVB Copyright © 2011, 2015 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.