Table 1. SKY13317-373LF Signal Descriptions 1 RFC Antenna. DC blocking capacitor required. 5 RF2 RF port 2. DC blocking capacitor required.
2 N/C No connect 6 V2 Switch logic control (see Table 4)
3 V1 Switch logic control (see Table 4) 7 V3 Switch logic control (see Table 4)
4 RF1 RF port 1. DC blocking capacitor required. 8 RF3 RF port 3. DC blocking capacitor required. Table 2. SKY13317-373LF Absolute Maximum Ratings (Note 1) parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. ESD HANDLING: Industry-standard ESD handling precautions must be adhered to at all times to avoid damage to this device.
Table 3. SKY13317-373LF Electrical Specifications (Note 1)
48 MHz, VLOW = 0 V,
Note 1: Performance is guaranteed only under the conditions listed in this table. Table 4. SKY13317-373LF Truth Table
Figure 13. SKY13317-373LF Tape and Reel Dimensions
DATA SHEET • SKY13317-373LF: SP3T SWITCH Skyworks Solutions, Inc. • Phone [949] 231-3000 • sales@skyworksinc.com • www.skyworksinc.com 200914L • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 5, 2022 9
Ordering Information
Model Name Manufacturing Part Number Evaluation Board Part Number SKY13317-373LF: SP3T Switch SKY13317-373LF SKY13317-373LF-EVB Copyright © 2022 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no r esponsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its d ocumentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this docume nt. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks’ Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT W ARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON -INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSL Y DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINE D WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCID ENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life -sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks custom ers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyw orks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards t o minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outs ide of Skyworks’ published specifications or parameters. Skyworks, the Skyworks symbol, Sky5®, SkyOne®, SkyBlue™, Skyworks Green™, ClockBuilder®, DSPLL®, ISOmodem®, ProSLIC®, and SiPHY® are trademarks or registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for identification purposes only and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.