Features

  • P16/200F heatsink
  • Isolated base modules
  • Forced air cooled Typical Applications
  • Industrial rectifiers
  • Softstarters
  • A C c o n t r o l
  • DC motor control Options No. 08767220 Characteristics Symbol Conditions min. typ. max. Unit Electrical Data Id Tamb=35°C no overload 360 A 150 % overload, 60s every 10 min. 258 388 A 200 % overload, 60s every 10 min. 217 435 A VCES 1200 V VDC DC voltage applied to the capacitor bank 510 V VAC network voltage (line side), -20% / +15% 380 V Visol 50 Hz / 1 min. 2500 V i2t Tvj = 25°C 145 kA 2s Tvj = 125°C 125 kA 2s (di/dt)cr Tvj = 125°C 200 A/µs (dv/dt)cr 1000 V/µs VGT 2V IGT 150 mA Ptot Tamb = 35°C 1015 W Rthja per component 0.53 K/W Tvj - 40 125 °C Fuse No fuse - A RC Resistance 33 Ω RC Capacitance 0.47 µF Thermal trip normally closed 75 °C Mechanical Data dv/dt AIR required airflow per fan m 3/h w approx. total weight kg Size Width x Depth x Height (with fan) 248 431 148 mm T stg 56 0 ° C Tamb 56 0 ° C Altitude Installation height w/o derating 1000 m Protection IP00 Pollution EN 50178 2 Fan Data Fan included in the stack (YES ) Type SKF 16A-230-01 V Fan Fan voltage 230 V fFAN Fan frequency 50 Hz IFAN Fan current 0,6 A PFAN Fan power 135 W

2 Rev. 6 – 18.11.2008 © by SEMIKRON Fig. 1 Maximal overload factor vs nom current and ovl duration, Tamb = 35°C Fig. 2 Maximal overload factor vs nom current and ovl duration, Tamb = 45°C Fig. 3 Maximal overload duration vs nom current and ovl factor, Tamb = 35°C Fig. 4 Maximal overload duration vs nom current and ovl factor, Tamb = 45°C Fig.5 Power losses Fig. 6 Thermal impedance Zth(j-a)

© by SEMIKRON Rev. 6 – 18.11.2008 3 This technical information specifies semiconductor devices but promises no characteristics. No warranty or guarantee expressed or implied is made regarding delivery, performance or suitability. Note: Stack design may vary depending upon the version. Please contact SEMIKRON for further details.