MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. SH6L THRU SH1L SOD-123FL MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) Dimensions in inches and (millimeters) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TA = 55OC Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 1) Typical Junction Capacitance (Note 2) SYMBOL VRRM VDC IFSM CJ TSTG VRMS UNITS Volts Volts Volts Amps1.0 130 15 12 Amps 0C/W 0C/W 0 C Storage Temperature Range R q J A Typical Thermal Resistance (Note 1) 30R q J L IO pF Operating Temperature Range TJ SH1L 150 -55 to + 150 0 C SH3L SH4L 200 300 35 140 210 SH2L 100 100 200 300 SH5L 400 280 400 SH6L SH1L SH3L SH4LSH2L SH5L SH6L 600 600 420 2006-12 CHARACTERISTICS Maximum Average Reverse Current at Rated DC Blocking Voltage VF SYMBOL IR mA Maximum Instantaneous Forward Voltage at 1.0A DC Volts 100 @TA = 25 o C @TA = 100 o C mA UNITS 1.0 1.3 1.7 trrMaximum Reverse Recovery Time (Note 4) nSec50 75 NOTES : 1. Thermal Resistance :Mounted on PCB. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. "Fully ROHS compliant","100% Sn plating (Pb-free)". .150 (3.8) .142 (3.6) .052 (1.32) .050 (1.28) .033 (0.85) .043 (1.08) .033 (0.85) .030 (0.75) .035 (0.90) .028 (0.70) .039 (1.00) .035 (0.90) .077 (1.95) .069 (1.75) .008 (0.20) .114 (2.9) .106 (2.7) SURFACE MOUNT HIGH EFFICIENCY RECTIFIER VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere

FEATURES

  • Low power loss, high efficiency * Low leakage * Low forward voltage * High current capability * High speed switching * High surge capability * High reliability MECHANICAL DATA * Epoxy: Device has UL flammability classification 94V-O * Mounting position: Any * Weight: 0.016 gram

AMBIENT TEMPERATURE, ( O 1.0 0.8 0.6 0.4 0.2 7550 175100 125 150 RATING AND CHARACTERISTICS CURVES ( SH1L THRU SH6L ) FIG.2 TYPICAL FORWARD CURRENT DERATING CURVE FIG.1 TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC AVERAGE FORWARD CURRENT, (A) trr +0.5A50 W NONINDUCTIVE 10 W NONINDUCTIVE -0.25A -1.0A 1cm SET TIME BASE FOR 20/1 ns/cm NOTES: 1 Rise Time = 7ns max. Input Impedance = 1 megohm. 22pF. 2. Rise Time = 10ns max. Source Impedance = 50 ohms. D.U.T

25 Vdc

(approx) ( - ) ( - ) ( + ) ( + ) NON- INDUCTIVE OSCILLOSCOPE (NOTE 1) PULSE GENERATOR (NOTE 2) Single Phase Half Wave 60Hz Resistive or Inductive Load INSTANTANEOUS REVERSE CURRENT, (uA) PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) 0.1 1.0 1000 100 6020 40 80 100 120 140 FIG.3 TYPICAL REVERSE CHARACTERISTICS TA = 25 O C TA = 75 O C TA = 100 O C

PEAK FORWARD SURGE CURRENT, (A) INSTANTANEOUS FORWARD VOLTAGE, (V) INSTANTANEOUS FORWARD CURRENT, (A) 1.0 0.3 0.1 0.03 0.01 3.0 RATING AND CHARACTERISTICS CURVES ( SH1L THRU SH6L ) FIG.4 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT REVERSE VOLTAGE, (V) JUNCTION CAPACITANCE, (pF) 200 100 0.20.1 1 0.4 21.0 4 10 20 40 100 FIG.6 TYPICAL JUNCTION CAPACITANCE 8.3ms Single Half Sine-Wave (JEDED Method) Pulse Width=300uS 1% Duty Cycle TJ = 25 O C TJ = 25 O C SH1L~SH3L SH1L~SH5L SH4L~SH5L SH6L SH6L

Dimensions in inches and (millimeters) 0.165 (4.19) REF .052 MIN. (1.32 MIN.) .033 MIN. (0.85 MIN.) .044 MIN. (1.12 MIN.) .033 MIN. (0.85 MIN.)

Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi- lity for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" paramet- ers which may be included on RECTRON data sheets and/ or specifications ca- n and do vary in different applications and actual performance may vary over ti- me. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other rela- ted applications where a failure or malfunction of component or circuitry may di- rectly or indirectly cause injury or threaten a life without expressed written appr- oval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rect- ron Inc and its subsidiaries harmless against all claims, damages and expendit- ures. DISCLAIMER NOTICE