Features

  • Available as a 3.3V High Precision PLL
  • Eight User Selectable PECL Output Frequencies
  • Jitter Generation OC-192 Compliant
  • 1.2” x 1.0” x 0.285”, Surface Mount
  • ROHS Compliant PLL

SFX800G Data Sheet #: SG162 Page 2 of 8 Rev: 02 Date: 09/17/10 © Copyright 2010 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice The SFX-800G is a high precision frequency translator that translates one input, greater than 1MHz, to one of eight selectable output frequencies between 10 MHz and 1 GHz. The SFX-800G supports all major FEC rates such as 15/14, 255/237 etc. SFX-800G is well suited for use in line cards, service termination cards and similar functions to provide reliable reference, phase locked, synchronization for TDM, PDH, SONET and SDH network equipment. The SFX-800G provides a Functional Block Diagram Figure 1 jitter filtered, wander following output signal synchronized to a superior Stratum or peer input reference signal. The SFX-800G includes a lock detect (LD) alarm output and a loss of reference (LOR) alarm output. The LVPECL outputs may be disabled for external testing purposes by asserting a high signal to the Enable/Disable pin. The SFX-800G package typical dimensions are 1.2” x 1.0” x 0.285”. Parts are assembled using high temperature solder to withstand surface mount reflow process. General Description F requency Divider Loop Filter PECL VCXO F requency Divider Q (Pin 12) In (Pin 1) Out Sel 1 (Pin 8) LD (Pin 10) Out Sel 2 (Pin 4) Out Sel 3 (Pin 7) Disab le (Pin 16) LOR (Pin 11) Microprocessor CIn (Pin 2) Q (Pin 14) SFX-800G Absolute Maximum Rating Table 1 Symbol Parameter Minimum Nominal Maximum Units Notes Vcc Power Supply Voltage (OptionD) -0.3 3.6 Volts VI Input Voltage -0.3 Vcc + 0.3 Volts Ts Storage Temperature (OptionF) -65 150 °C

SFX800G Data Sheet #: SG162 Page 3 of 8 Rev: 02 Date: 09/17/10 © Copyright 2010 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice Pin Description Table 3 Pin # Connection Description

1 In Input Frequency, Signal is AC coupled

2 CIn Complementary Input Frequency, Signal is AC coupled

3 GND Ground

4 Out Sel 2 Output Frequency Select 2

5 NC Do Not Connect

6 NC Do Not Connect

7 Out Sel 3 Output Frequency Select 3

8 Out Sel 1 Output Frequency Select 1

9 Vcc Supply Voltage

10 LD (Output) Lock Detect

Logic “1” indicates that the unit is locked to the input reference Logic “0” indicates that the reference is lost or out of lock range

11 LOR Loss of Reference

Logic “1” indicates that reference is present Logic “0” indicates that reference is lost

12 Q PECL Output (Low when Disabled)

13 GND Ground

14 Q PECL Complemetary Output (High when Disabled)

15 GND Ground

16 Disable (Input) Logic “0” (or no connect) = PECL Outputs are Enabled

Logic “1” = PECL Outputs are Disabled Specifications Table 2 Symbol Parameter Minimum Nominal Maximum Units Notes fIN Input Frequencies (Comp PECL) 1 250 MHz Input Frequencies (HCMOS .008 0 250 MHz 2.0 fOUT Output Frequencies (Comp PECL) 10 1125 MHz Vcc Supply Voltage 3.135 3.3 3.465 Volts ICC Supply Current 175 mA VOH High Level Output Voltage 2.275 V VOL Low Level Output Voltage 1.68 V TR/TF Rise/Fall Time (20% - 80%) 180 ps SYM Output Symmetry 45 55 % JGEN Jitter Generation RMS 0.5 1 ps (12 kHz - 20 MHz) JTRAN Jitter Transfer 0.1 dB 1.0 APR Input Frequency Tracking ±300 ppm TOP Operating Temperature 0 70 °C CALVCO Self VCO Calibration 1.5 sec 3.0 Jitter Bandwidth - 450 - Hz Phase Detector Comparison Frequency - 24 - kHz 2.0: CIN (Pin 2) is not used internally. It is AC coupled and loaded with a 180 Ω resistor to ground. 3.0: VCO calibration occurs with each power-up and with each new output frequency selection. See figure 3 for the proper calibration sequence. Without a proper VCO calibration sequence, the unit will not lock and the output frequency could vary substantially from nominal.

SFX800G Data Sheet #: SG162 Page 4 of 8 Rev: 02 Date: 09/17/10 © Copyright 2010 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice Output Load and Power Supply Filtering Recommendations Figure 2 50Ω50Ω V CC -2 V DC (F OUT ) * ** * It is highly recommended that either a linear regulator or b ypass capacitors be used. Typical v alues would be 10 uF , 0.1 uF , 100 pF . F requency Divider Loop Filter PECL VCXO F requency Divider Q (Pin 12) In (Pin 1) Out Sel 1 (Pin 8) LD (Pin 10) Out Sel 2 (Pin 4) Out Sel 3 (Pin 7) Disab le (Pin 16) LOR (Pin 11) Microprocessor CIn (Pin 2) Q (Pin 14) SFX-800G Out Sel 3 Out Sel 2 Out Sel 1 Output Freq. Selected 0 0 0 Output Freq. 1 0 0 1 Output Freq. 2 0 1 0 Output Freq. 3 0 1 1 Output Freq. 4 1 0 0 Output Freq. 5 1 0 1 Output Freq. 6 1 1 0 Output Freq. 7 1 1 1 Output Freq. 8 Output Select Table Table 4 Note: VCO calibration occurs with each new output frequency selection. See figure 3 for the proper calibration sequence. Without a proper VCO calibration sequence, the unit will not lock and the output frequency could vary substantially from nominal. LOR (Loss of Reference) When the external reference is <= 1MHz, LOR is LOW When the external reference is > 1MHz, LOR is HIGH LD (Lock Detect) When the Phase Detector Error is <= 7ns (typ) for 5 cycles, LD is HIGH After LD is HIGH, it will go LOW if the Phase Detector Error of any cycle is >15ns (typ) Alarm Function Table 5

SFX800G Data Sheet #: SG162 Page 5 of 8 Rev: 02 Date: 09/17/10 © Copyright 2010 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice VCO Calibration Sequence Flowchart Figure 3 Note: * A valid reference must be within the input frequency tracking range of the unit and must meet the jitter requirements of the LD alarm (see Alarm Function Table) ** As indicated in the Alarm Function Table, the LOR alarm does not validate the external reference but simply indicates that the reference frequency > 1 MHz is present.. Po wer-up or New Output Fr equenc y Selec tion * V alid Reference Pr esent? Reference Ex ternally Validated? Alternate is L OR ** HIGH? To ggle an y Output Fr equenc y Select Pin Internal VCO Calibration ~1.5s Is LD High? Calibration Sequenc e Complet e Yes No No Yes Yes No No

SFX800G Data Sheet #: SG162 Page 7 of 8 Rev: 02 Date: 09/17/10 © Copyright 2010 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice

Ordering Information

Part Input Output Output Output Output Output Output Output Output Number Frequency Frequency Frequency Frequency Frequency Frequency Frequency Frequency Frequency A (MHz) 1 (MHz) 2 (MHz) 3 (MHz) 4 (MHz) 5 (MHz) 6 (MHz) 7 (MHz) 8 (MHz) 1.0240 MHz 26.0000 MHz 114.0000 MHz 657.4219 MHz 1.5440 MHz 27.0000 MHz 125.0000 MHz 666.5143 MHz 2.0480 MHz 29.4912 MHz 139.2640 MHz 669.1281 MHz 4.0960 MHz 32.7680 MHz 155.5200 MHz 669.3266 MHz 6.4800 MHz 37.0560 MHz 156.2500 MHz 672.1627 MHz 8.1920 MHz 38.8800 MHz 161.1328 MHz 690.5692 MHz 10.0000 MHz 44.4343 MHz 166.6286 MHz 693.4830 MHz 12.8000 MHz 44.7360 MHz 167.3316 MHz 704.3806 MHz 13.0000 MHz 51.8400 MHz 168.0407 Mhz 707.3527 MHz 15.0000 MHz 61.4400 MHz 311.0400 MHz 710.9486 MHz 16.3840 MHz 65.5360 MHz 531.2500 MHz 719.7344 MHz 19.4400 MHz 77.7600 MHz 624.7048 MHz 777.6000 MHz 20.0000 MHz 78.1250 MHz 622.0800 MHz 20.1416 MHz 78.6432 MHz 625.0000 MHz 20.4800 MHz 82.9440 MHz 627.3596 MHz 22.2171 MHz 112.0000 MHz 644.5313 MHz Contact Factory for other Frequencies

2111 Comprehensive Drive

Aurora, Illinois 60505 Phone: 630-851-4722 Fax: 630- 851- 5040 www.conwin.com Revision Revision Date Note P00 6/5/08 Preliminary Release P01 12/23/08 Update Output Frequencies P02 02/03/09 Frequency updates R00 05/07/09 Release and Operating Temperature Revisions R01 08/09/10 Add New Model to Ordering Information R02 09/17/10 Output Frequency updates Consult the factory for a Part Number for your application