Silicon NPN Phototransistor NPN-Silizium-Fototransistor Version 1.1 SFH 310, SFH 310 FA SFH 310 FA SFH 310
Ordering Information
Features: Besondere Merkmale:
- Spectral range of sensitivity: 450 nm ... 1100 nm (SFH 310), 740 nm ... 1100 nm (SFH 310 FA)
- Spektraler Bereich der Fotoempfindlichkeit: (SFH 310 FA)
- Package: 3mm Radial (T 1), Epoxy • Gehäuse: 3mm Radial (T 1), Harz
- Special: high photosensitivity • Besonderheit: hohe Fotoempfindlichkeit Applications Anwendungen
- Photointerrupters • Lichtschranken
- Industrial electronics • Industrieelektronik
- For control and drive circuits • Messen / Steuern / Regeln Type: Photocurrent Ordering Code Typ: Fotostrom Bestellnummer λ = 950 nm, Ee = 0.5 mW/cm2, VCE = 5 V IPCE [µA] SFH 310 630 ... 3200 Q62702P0874 SFH 310-2/3 630 ... 2000 Q62702P3595 SFH 310 FA 400 ... 3200 Q62702P1673 SFH 310 FA-2/3 630 ... 2000 Q62702P3596 Note: Only one bin within one packing unit (variation less than 2:1) Anm.: Nur eine Gruppe pro Verpackungseinheit (Streuung kleiner 2:1)
Version 1.1 SFH 310, SFH 310 FA Maximum Ratings (TA = 25 °C) Grenzwerte Characteristics (TA = 25 °C) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit SFH 310 SFH 310 FA Operating and storage temperature range Betriebs- und Lagertemperatur Top; Tstg -40 ... 100 °C Collector-emitter voltage Kollektor-Emitter-Spannung VCE 35 V Collector current Kollektorstrom IC 50 mA Collector surge current Kollektorspitzenstrom (τ < 10 µs) ICS 100 mA Total power dissipation Verlustleistung Ptot 165 mW Thermal resistance Wärmewiderstand RthJA 450 K / W Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit SFH 310 SFH 310 FA Wavelength of max. sensitivity Wellenlänge der max. Fotoempfindlichkeit λ S max 880 890 nm Spectral range of sensitivity Spektraler Bereich der Fotoempfindlichkeit λ10% 450 ... 1100 740 ... 1100 nm Radiant sensitive area Bestrahlungsempfindliche Fläche A0 . 1 1 m m 2 Dimensions of chip area Abmessung der Chipfläche L x W 0.5 x 0.5 mm x mm
Version 1.1 SFH 310, SFH 310 FA 2014-01-14 3 Half angle Halbwinkel ϕ ± 25 ° Capacitance Kapazität CE = 0 V, f = 1 MHz, E = 0) CCE 7.5 pF Dark current Dunkelstrom (VCE = 10 V, E = 0) ICE0 1 (≤ 50) nA Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit SFH 310 SFH 310 FA
Version 1.1 SFH 310, SFH 310 FA Grouping (TA = 25 °C, λ = 950 nm) Gruppierung Group Min Photocurrent Max Photocurrent Typ Photocurrent Rise and fall time Gruppe Min Fotostrom Max Fotostrom Typ Fotostrom Anstiegs- und Abfallzeit Ee = 0.5 mW/cm2, VCE = 5 V Ee = 0.5 mW/cm2, VCE = 5 V SFH 310: E V = 1000 lx, Std. Light A, VCE = 5 V IC = 1 mA, VCC = 5 V, RL = 1 kΩ IPCE, min [µA] IPCE, max [µA] IPCE [µA] tr, tf [µs] -2 630 1250 3000 5 -3 1000 2000 4800 8 -4 1600 3200 7700 12 Group Collector-emitter saturation voltage Gruppe Kollektor-Emitter Sättigungsspannung IC = IPCEmin x 0.3, Ee = 0.5 mW/cm2 VCEsat [mV] -2 150 -3 150 -4 150 Note.: I PCEmin is the min. photocurrent of the specified group. Anm.: I PCEmin ist der minimale Fotostrom der jeweiligen Gruppe.
Version 1.1 SFH 310, SFH 310 FA 2014-01-14 5 Relative Spectral Sensitivity Relative spektrale Empfindlichkeit SFH 310 Srel = f(λ) Relative Spectral Sensitivity Relative spektrale Empfindlichkeit SFH 310 FA Srel = f(λ) Photocurrent Fotostrom IPCE = f(Ee), VCE = 5 V Photocurrent Fotostrom IPCE = f(VCE), Ee = Parameter 400 nm OHF04042 100 λ relS 500 600 700 800 900 1100 400 nm OHF04075 100 λ relS 500 600 700 800 900 1100
Version 1.1 SFH 310, SFH 310 FA Photocurrent Fotostrom IPCE / IPCE(25°C) = f(TA), VCE = 5 V Dark Current Dunkelstrom ICEO = f(VCE), E = 0 Dark Current Dunkelstrom ICEO = f(TA), E = 0 Collector-Emitter Capacitance Kollektor-Emitter Kapazität CCE = f(VCE), f = 1 MHz, E = 0 T OHF01524 A -25 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 0 25 50 75 100 Ι PCE PCEΙ 25 C OHF04049 VCE 010 101 10-1 10-2 CEOI nA 0V 5 10 15 20 25 30 35 nA OHF04050 CEOI AT -210 -110 100 110 102 310 104 -25 0 25 50 75 100˚C 0 pF OHF04051 CEC CEV 10-3 10-2 10-1 100 101 102V
Version 1.1 SFH 310, SFH 310 FA 2014-01-14 7 Total Power Dissipation Verlustleistung Ptot = f(TA) Directional Characteristics Winkeldiagramm Srel = f(ϕ)
Version 1.1 SFH 310, SFH 310 FA Package Outline Maßzeichnung Dimensions in mm (inch). / Maße in mm (inch). 0.4 (0.016) 0.6 (0.024) 3.1 (0.122) 3.4 (0.134) Area not flat 5.7 (0.224) 6.1 (0.240) ø2.7 (0.106) ø2.9 (0.114) 4.8 (0.189) 4.4 (0.173) 3.7 (0.146) 3.5 (0.138) 27.0 (1.063) 29.0 (1.142) spacing 2.54 (0.100) 0.8 (0.031) 0.4 (0.016) 0.4 (0.016) 0.7 (0.028) 0.4 (0.016) 0.6 (0.024) 1.2 (0.047) 1.8 (0.071) GEXY6710 0.9 (0.035) 1.1 (0.043) Collector
Version 1.1 SFH 310, SFH 310 FA 2014-01-14 9 TTW Soldering Wellenlöten (TTW) IEC-61760-1 TTW / IEC-61760-1 TTW 00 s OHA04645 100 150 200 250 300 t T 235 ˚C - 260 ˚C First wave 20 40 60 80 100 120 140 160 180 200 220 240 Second wave 10 s max., max. contact time 5 s per wave Preheating TΔ 100 ˚C 120 ˚C 130 ˚C Typical Cooling ca. 3.5 K/s typical ca. 2 K/s ca. 5 K/s Continuous line: typical process Dotted line: process limits < 150 K
Version 1.1 SFH 310, SFH 310 FA Disclaimer Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered. Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist.
Version 1.1 SFH 310, SFH 310 FA 2014-01-14 11 Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.