SFH-06SFSF-A3-2 ERAVANT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

SFH-06SFSF-A3-2 Rev. 1.2 www.eravant.com | 3043 Kashiwa Street, Torrance, CA 90505 Phone: 424-757-0168 | Fax: 424-757-0188 | Email: support@eravant.com Page | 1 SAGE Millimeter, Inc. Copyright © 2023 by Eravant D-Band Harmonic Mixer, 14th Harmonic, Spectrum Analyzer Description: Model SFH-06SFSF-A3-2 is a D-Band balanced harmonic mixer that is specially designed for use with separate LO and IF ports. The mixer employs high performance, GaAs Schottky diodes and a balanced configuration to produce a superior RF performance. With an IF range of DC to 1.6 GHz, the harmonic mixer uses the harmonic number 14 of a 5.0 to 12.0 GHz LO at +16 dBm to translate 110.0 to 170.0 GHz. The harmonic mixer has a typical conversion loss of 45 dB. The mixer can be used as other even harmonic numbers, such as 10, 12, and 16 etc. with various conversion loss performance. In general, the lower the harmonics, the lower the conversion loss. Features:

  • Full Waveguide Band Operation
  • No External Bias Required
  • Even Harmonic Detection
  • Calibrated for 8th Harmonic Detection Applications:
  • Spectrum Analyzers
  • Frequency Meters
  • Phase Locked Loops Electrical Specifications: Parameter Minimum Typical Maximum RF Frequency 110 GHz 170 GHz LO Frequency 5.0 GHz 12.0 GHz IF Frequency DC 1.6 GHz RF Power - 20 dBm +19 dBm LO Power +16 dBm +19 dBm Harmonic Number 14 Conversion Loss 45 dB Specification Temperature +25 °C Operating Temperature 0 °C +50 °C Mechanical Specifications: Item Specification RF Port WR-06 Waveguide with UG-387/U-M Anti-Cocking Flange LO Port SMA (F) IF Port SMA (F) Case Material Brass Finish Gold Plated Weight 5.4 Oz Outline FH-D2-A

SFH-06SFSF-A3-2 Rev. 1.2 www.eravant.com | 3043 Kashiwa Street, Torrance, CA 90505 Phone: 424-757-0168 | Fax: 424-757-0188 | Email: support@eravant.com Page | 2 SAGE Millimeter, Inc. Copyright © 2023 by Eravant D-Band Harmonic Mixer, 14th Harmonic, Spectrum Analyzer Mechanical Outline: (Unless otherwise specified, all dimensions are in inches [millimeters]) 110 115 120 125 130 135 140 145 150 155 160 165 170 Conversion Loss (dB) Frequency (GHz) Typical Conversion Loss vs. Frequency PRF = -20 dBm

SFH-06SFSF-A3-2 Rev. 1.2 www.eravant.com | 3043 Kashiwa Street, Torrance, CA 90505 Phone: 424-757-0168 | Fax: 424-757-0188 | Email: support@eravant.com Page | 3 SAGE Millimeter, Inc. Copyright © 2023 by Eravant D-Band Harmonic Mixer, 14th Harmonic, Spectrum Analyzer Note:

  • The harmonic mixer is for small signal detection. The recommended the RF power range is -10 dBm or below.
  • The Harmonic mixer work in any even harmonics of LO to yield the IF frequency in the range of DC to 1.6 GHz with different conversion loss.
  • Eravant reserves the right to change the information presented without notice. Caution:
  • Exceeding absolute maximum ratings of the mixer will damage the device.
  • Any foreign objects in the waveguide will degrade performance and/or damage the device.
  • The mixer is a static sensitive device. Always follow ESD rules when working with the mixer. wrench, model SCH-08008-S1, is highly recommended.