Features
- Terminal height 17 mm
- Chips soldered directly to isolated substrate Typical Applications*
- Input Bridge Rectifier for AC/DC motor control
- Power supply Absolute Maximum Ratings Symbol Conditions Values Unit Chip IT(AV) sinus 180° Tc =8 5° C 240 A Tc = 100 °C 200 A ITSM 10 ms Tj =2 5° C 2250 A Tj = 130 °C 1900 A i2t 10 ms Tj =2 5° C 25300 A 2s Tj = 130 °C 18000 A 2s VRSM 1700 V VRRM 1600 V VDRM 1600 V (di/dt)cr Tj = 130 °C 100 A/µs (dv/dt)cr Tj = 130 °C 1000 V/µs Tj -40 ... 130 °C Module Tstg -40 ... 125 °C Visol AC sinus 50Hz 1m i n 4000 V 1s 4800 V Characteristics Symbol Conditions min. typ. max. Unit Chip VT Tj =2 5° C , IT = 300 A 1.9 V VT(TO) Tj = 130 °C 0.85 V rT Tj = 130 °C 4m Ω IDD;IRD Tj = 130 °C, VDD = VDRM; VRD = VRRM 24 mA tgd Tj =2 5° C , IG =1A , d iG/dt = 1 A/µs 1µ s tgr VD = 0.67 * VDRM 2µ s tq Tj = 130 °C 150 µs IH Tj =2 5° C 150 250 mA IL Tj =2 5° C , RG =3 3 Ω 300 600 mA VGT Tj =2 5° C , d . c . 3V IGT Tj =2 5° C , d . c . 150 mA VGD Tj = 130 °C, d.c. 0.25 V IGD Tj = 130 °C, d.c. 6m A Rth(j-c) per thyristor K/W per module K/W Rth(j-c) sin. 180° per thyristor 0.32 K/W per module 0.32 K/W Rth(j-c) per thyristor K/W per module K/W Module Rth(c-s) per chip K/W per module 0.04 K/W Ms to heat sink (M5) 3 5 Nm Mt to terminals (M6) 2.5 5 Nm a 5 * 9,81 m/s 2 w3 5 0 g
2 Rev. 29 – 05.03.2010 © by SEMIKRON Fig. 4L: Power dissipation per module vs. direct current Fig. 4R: Power dissipation per module vs. case temperature Fig. 5: Recovered charge vs. current decrease Fig. 6: Transient thermal impedance vs. time Fig. 7: On-state characteristics Fig. 8: Surge overload current vs. time
© by SEMIKRON Rev. 29 – 05.03.2010 3
4 Rev. 29 – 05.03.2010 © by SEMIKRON This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX * The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and syste ms is subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our personal. Fig. 9: Gate trigger characteristics spring configuration SEMiX 13