SDR-960 MEANWELL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE Note.7 FREQUENCY RANGE EFFICIENCY (Typ.)INPUT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER TEMPERATURE SAFETY STANDARDS WORKING TEMP. Note.5 CURRENT SHARING WORKING HUMIDITY STORAGE TEMP., HUMIDITY DC OK REALY CONTACT RATINGS (max.) TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVERLOAD OVER VOLTAGE AC CURRENT (Typ.) 1000ms, 100ms/230VAC at full load 14ms / 230VAC at full load 180 ~ 264VAC 254 ~ 370VDC 47 ~ 63Hz 94% 6A/230VAC 56 ~ 65V 94% COLD START 50A / 230VAC <3.5mA / 240VAC 29 ~ 33V after 30 seconds if the peak load condition is removed Constant current limiting within 130 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage, re-power on to recover 90℃±5℃ (TSW) detect on heatsink of power switch Protection type : Shut down o/p voltage, recovers automatically after temperature goes down UL508, approvedTUV EN60950-1 Compliance to EN55022 (CISPR22), EN61204-3 Conduction class B, Radiation class A, EN61000-3-2,-3 -30 ~ +70℃ (Refer to "Derating Curve") Please refer to function manual 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load 20 ~ 95% RH non-condensing ±0.03%/℃ (0 ~ 50℃) Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 69.8K hrs min. MIL-HDBK-217F (25℃) 2.47Kg ; 6pcs/15.8Kg/1.55CUFT SDR-960-48 48V 20A 0 ~ 20A 960W 250mVp-p 48 ~ 55V ±1.0% ±0.5% ±1.0% SDR-960-24 24V 40A 0 ~ 40A 960W 180mVp-p 24 ~ 28V ±1.0% ±0.5% ±1.0% ■ Features : SDR-960 series WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH ENVIRONMENT SAFETY & FUNCTION EMC (Note 4) PROTECTION RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. 3 seconds peak power max. and the average output power should not exceed the rate power. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. 8. Consult MEAN WELL for deployment of Radiation class B. 960W Single Output Industrial DIN RAIL with PFC Function ‧AC input 180~264VAC only ‧130% p ‧110mm slim design ‧High efficiency 94% and low power dissipation ‧Protections: Short circuit / Overload / Over voltage / Over temperature ‧Cooling by free air convection ‧Built-in constant current limiting circuit ‧Can be installed on DIN rail TS-35/7.5 or 15 ‧UL508(industrial control equipment)approved ‧EN61000-6-2(EN50082-2) industrial immunity level ‧Current sharing up to 3840W(3+1) ‧Built-in DC OK relay contact ‧100% full load burn-in test ‧3 years warranty eak load capability Built-in active PFC function compliance to EN61000-3-2 POWER FACTOR (Typ.) PF≧0.95/230VAC at full load EMC IMMUNITY EMC EMISSION Note.8 PEAK CURRENT PEAK POWER Note.6 26A52A 1248W (3sec.) Protection type : Shut down o/p voltage, with auto-recovery or re-power on to recover Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A Normally w more than 3 and then shut down o/p voltage with auto-recoveryorks within 105 ~ 130% rated output power for seconds File Name:SDR-960-SPEC 2012-11-07

File Name:SDR-960-SPEC 2012-11-07 Mechanical Specification Case No.214A Unit:mm Block Diagram DC OK Relay Contact Contact Close PSU turns on / DC OK. PSU turns off / DC Fail. 30V/1A resistive load. Contact Open Contact Ratings (max.) DETECTION PWM & PFC CIRCUIT O.L.P. O.T.P. U.V.P. EMI FILTER RECTIFIERS POWER SWITCHING FILTER RECTIFIERS +V DC OK CURRENT SHARE I/P FG CONTROL O.V.P. CURRENT SHARE O.C.P. PFC CIRCUIT PFC CONTROL 1 2 3 4 Terminal Pin No. Assignment (TB1) Terminal Pin No. Assignment (TB2) Pin No. Pin No. 1 1,2,3 2 4,5,6 Assignment Assignment FG AC/L AC/N DC OUTPUT +V DC OUTPUT -V ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 SDR-960 series960W Single Output Industrial DIN RAIL with PFC Function 150 110 DC OK TB1 CN205 1234 +V ADJ TB2 125.2 PFC fosc : 65KHz PWM fosc : 60KHz Control Pin (CN205) : DINKLE ECH250R-04P or equivalent Pin No. 3,4 Assignment P-(Current Share) P+(Current Share) DC OK Relay Contact Mating Housing 0.081~0.517mm DINKLE ESC250V-04P or equivalent (Including in the single package) (28~20AWG) Wire Diameter

AMBIENT TEMPERATURE (℃) LOAD (%) -30 0 10 20 30 40 50 60 70 100 130 (VERTICAL) Output derating VS input voltageDerating Curve File Name:SDR-960-SPEC 2012-11-07 INPUT VOLTAGE (V) 60Hz LOAD (%) 100 180 190 200 210 220 230 240 250 264 Function Manual 1. Current sharing (1) Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel). (2) Difference of output voltages among parallel units should be less than 0.2V. (3) The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9. (4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. (5) The power supplies should be paralleled using short and large diameter wiring and then connected to the load. (6) When in parallel operation, the minimum output load should be greater than 5% of total output load. (Min. load >5% rated current per unit x number of unit) (7) In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition. The other PSUs (slaves) may go into standby mode and their output LEDs & relays will not turn on. (8) Some minor noise may be heard at light load condition under parallel operation. This is a normal phenomenon and the performance of the PSU will not be influenced. LOAD -V +V P- P- P- P- CN205 CN205 CN205 CN205 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 P+ P+ P+ P+ DC OK DC OK DC OK DC OK DC OK DC OK DC OK DC OK TB2TB2TB2TB2 +V+V+V+V -V-V-V-V PSUPSUPSUPSU P-(pin1) P+(pin2) Peak Loading 1248W 1248W ( 1 ) ( 2 ) 960W 480W 50 sec. 15 sec.3 sec. 3 sec. ContinuousFor 3 sec. (typ.) SDR-960 series960W Single Output Industrial DIN RAIL with PFC Function P+ and P- lines should be twisted in pairs