SDN10-24-100P EMERSON-NETWORKPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
Features
- Power Factor Correction (per EN61000-3-2)
- Auto Select 115/230 Vac, 50/60 Hz Input
- Improved metal mounting clip
- DC OK Signal
- Adjustable Voltage
- Parallel Capability standard on all units
- Industrial grade design - -10°C to 60°C operation without derating. Indefinite short circuit, overvoltage and overtemperature protection. - Powers high inrush loads without shutdown or foldback - Rugged metal case and DIN connector
- Narrow width on rail for space critical applications
- User-friendly front panel - Large, rugged, accessible, multiple connection screw terminations - Easy installation
- 12 Vdc and 48 Vdc single phase models available
- Highly efficient >90% switching technology
- High MTBF and reliability Accessories
- SDN-C Redundant Modules
- Chassis Mount Bracket (SDN-PMBRK2) Certifications and Compliances * All Models UL 508 Listed IND. CONT. EQ. E61379 Listed, Ind. Control Equipment, E61379 - UL 508, CSA C22.2 No. 107.1 UL 60950 E137632 CUL/CSA-C22.2 No. 234-M90 UL Recognized Component, ITE, E137632 - UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition UL 60950 E137632 CUL/CSA-C22.2 No. 234-M90 UL Recognized Component, Haz. Loc., E234790 - ISA 12.12.01, CSA C22.2 No. 213 - Class I, Division 2, Groups A, B, C, D - Low Voltage Directive - IEC/EN60950-1, 2nd Edition
- Sag Immunity: SEMI F47
- RoHS Compliant Models SDN 2.5-24-100P , SDN 4-24-100LP
- Class II per UL 1310, CSA C22.2 No. 223
Related Products
- SVL Series
- SDP™ Series
- SCP Series
- SCL Series
- SDU UPS UL 508 Listed IND. CONT. EQ. E61379 UL 60950 E137632 CUL/CSA-C22.2 No. 234-M90 EMC and Low Volt. Directive E61379 E137632 E234790 * Refer to user manual for installation requirements when used in hazardous locations.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © September 2019 131 SDN-P Specifications (Single Phase), 24 Vdc Output
Description
SDN 2.5-24-100P SDN 4-24-100LP SDN 5-24-100P SDN 10-24-100P Input Nominal Voltage 115/230 Vac, Auto select -AC Range 85-264 Vac 85-132/176-264 Vac -DC Range 1 90 - 375 Vdc 210 - 375 Vdc -Frequency 47 - 63 Hz -Inrush current max. typ. < 25 A typ. < 20 A typ. < 40 A Power Factor Correction Units Fulfill EN61000-3-2 Output Nominal Voltage 24 Vdc (22.5 - 28.5 Vdc adj.)
24 Vdc
(22.5 - 25.7 Vdc adj.) (22.5 - 28.5 Vdc adj.) -Tolerance < ±2% overall (combination Line, load, time and temperature related changes) -Ripple 4 < 50 mVpp Overvoltage Protection < 33 Vdc < 27 Vdc < 33 Vdc Nominal Current 2.5 A (60 W) 3.8 A (92 W) 5 A (120 W) 10 A (240 W) -Current Limit Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current) Holdup Time 5 > 20 ms @ full load Parallel Operation Single or Parallel use is selectable via Front Panel Switch (SDN 2.5, 4 should not be used in parallel as Class II rating would be violated.) General EMC: -Emissions EN61000-6-3, -4; Class B EN55011, EN55022 Radiated and Conducted including Annex A. EN61000-3-2 -Immunity EN61000-6-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class 4, EN61000-4-11; Temperature Storage: -25°C...+85°C Operation. -10°-60°C full power with operation to 70°C possible with a linear derating to half power from 60°C to 70°C (Convection cooling, no forced air required). Operation up to 50% load permissible with sideways or front-side-up mounting orientation. Humidity The relative humidity is < 90% RH, noncondensing; IEC 68-2-2, 68-2-3. MTBF: > 820,000 hours > 640,000 hours > 600,000 hours - Standard Bellcore Issue 6 Method 1 Case 3 @ 40°C Warranty 5 year limited warranty General Protection/Safety Protected against continuous short-circuit, overload, open-circuit. Protection Class I (IEC536), degree of protection IP20 (IEC 529) Safe low voltage: SELV (acc. EN60950) Status Indicators Green LED and DC OK signal (N.O. Solid State Contact rated 200 mA / 60 Vdc) Installation Fusing -Input Internally fused. External 10 A slow acting fusing for the input is recommended to protect input wiring. -Output Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/ loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Mounting Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required). Connections Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for flexible conductors. Output: Two connectors per output, connector size range: 16-10 AWG (1.5 - 6 mm2) for solid conductors. Case Fully enclosed metal housing with fine ventilation grid to keep out small parts. -Free Space 25 mm above and below, 25 mm left and right, 10 mm in front 25 mm above and below, 25 mm left and right, 15 mm in front 70 mm above and below, 25 mm left and right, 15 mm in front Dimensions - WxDxH in (mm) 4.88. x 1.97 x 4.55 (124.0 x 50.0 x 116.0) 4.88 x 2.56 x 4.55 (124.0 x 65.0 x 116.0) 4.88 x 3.26 x 4.55 (124.0 x 83.0 x 116.0) 1. Not UL listed for DC input. 2. Input current ratings are conservatively specified with low input, worst case efficiency and power factor. 3. Losses are heat dissipation in watts at full load, nominal input line. 4. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 5. Full load, 100 Vac Input @ Tamb = +25°C
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © September 2019 132 SDN-P Specifications (Single Phase), 12 Vdc and 48 Vdc Output Description Catalog Number SDN 9-12-100P SDN 5-48-100P Input Nominal Voltage 115/230 Vac auto select -AC Range 85-132/176-264 Vac; 210 - 375 Vdc -DC Range 1 210 - 375 Vdc -Frequency 47 - 63 Hz Nominal Current 2 2.0 A / 1.5 A 4 A / 2.3 A -Inrush current max. Typ. < 20 A typ. < 40 A Efficiency (Losses 3) > 82 % (23.4 W) > 87 % (32.6 W) Power Factor Correction Units fulfill EN61000-3-2 Output Tolerance < ±2 % overall (combination Line, load, time and temperature related changes) -Line Regulation < 0.5% -Load Regulation < 0.5% -Time & Temp. Drift < 1% Ripple 4 < 50 mVpp Overvoltage Protection < 16 Vdc with auto-recovery < 60 Vdc with auto-recovery Nominal Current 9 A (108 W) 5 A (240 W) -Current Limit 110% of nominal - Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current) Holdup Time 5 >20 ms @ full load Parallel Operation Supplies will not be damaged with parallel operation Power Back Immunity 16 Vdc 60 Vdc General EMC: -Emissions EN61000-6-3, EN61204-3, EN55022 Class B, EN61000-3-2, EN61000-3-3 -Immunity EN61000-6-2, EN61204-3, EN55024, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000- 4-11 Temperature Storage: -25 to +85°C, Operation -10 to +60°C full power; with linear derating to half power from 60 to 70°C (Convection cooling, no forced air required). Operation up to 50% load permissible with sideways or front-side-up mounting orientation. Humidity < 90% RH, non-condensing; IEC 68-2-2, 68-2-3 MTBF: >500,000 hrs - Standard Telcordia/Bellcore, Issue Case 3 @ 25°C Warranty 5 year limited warranty General Protection/Safety Protected against continuous short -circuit, continuous overload, continuous open circuit. Protection Class I (IEC536), Degree of Protection IP20 (IEC 529) Safe low voltage: SELV (acc. EN60950) Status Indicators (Visual) Green LED on when Vout > 75% (with ± 5% tolerance) of nominal output voltage Status Indicators (Relay) Normally Open solid state relay - signal active when Vout >70% of nominal output voltage (rated up to 200 mA, 60 Vdc) Installation Fusing -Input Internally fused -Output Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required if Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Mounting Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Unit should handle normal shock and vibration of industrial use and transportation without falling off the rail. Connections Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. Output: Two terminals per output, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. Case Fully enclosed metal housing with fine ventilation grid to keep out small parts. -Free Space 70 mm above and below, 25 mm left and right, 15 mm in front Weight - lbs (kg) 2.4 (1.10) 3.3 (1.50) 1. Not UL listed for DC input. 2. Input current ratings are conservatively specified with low input, worst case efficiency and power factor. 3. Losses are heat dissipation in watts at full load, nominal input line. 4. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 5. Full load, 100 Vac Input @ Tamb = +25°C
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © September 2019 133 24-28 V 115/230 VAC 1.3-0.7A50/60 HZ US LISTED Power Supply SDN 2.5-24-100P SOL A Parallel Single C LU LN 24 VDC /2 .5 A + + NEC Class2 Power Supply OK - - OK SDN-P Series Dimensions W D H Catalog Number Dimensions - inches (mm) H W D
12 Vdc
48 Vdc
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © September 2019 134 SDN-P Series Mounting DIN Rail Mounting Snap on the DIN Rail: 1. Tilt unit slightly backwards 2. Put it onto the DIN Rail 3. Push downwards until stopped 4. Push at the lower front edge to lock 5. Shake the unit slightly to ensure that the retainer has locked Alternative Panel Mount: Using the optional SDN-PMBRK2 accessory, the unit can be screw mounted to a panel. Detachment from DIN Rail: Chassis Mounting Instead of snapping a SolaHD SDN unit on the DIN Rail, you can also attach it using the screw mounting set SDN-PMBRK2. This set consists of two metal brackets, which replace the existing two aluminum profiles. Dimensions - in. (mm) 1.59 (40.4) .18 (4.6).86 (21.8) .40 (10.2) .60 (15.2) 1.30 (33.0) 1.80 (45.7) .35 (8.9) .70 (17.8) .51 (13.0) .43 (10.9) .23 (5.8) .08 (2.0) .23 (5.8) .25 (6.4) .26 (6.6) 2.16 (54.9) .60 (15.2)