cui.com date 01/29/2018 page 1 of 6 SERIES: SDM36-U │ DESCRIPTION: AC-DC POWER SUPPLY MODEL output voltage output current output power ripple and noise1 efficiency level (Vdc) max (A) max (W) max (mVp-p) SDM36-5-U 5 5 25 80 VI SDM36-7.5-U 7.5 4 30 80 VI SDM36-9-U 9 4 36 90 VI SDM36-12-U 12 3 36 120 VI SDM36-15-U 15 2.4 36 150 VI SDM36-18-U 18 2 36 180 VI SDM36-24-U 24 1.5 36 240 VI Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, output terminated with 0.1 μF multilayer ceramic and 10 μF low ESR electrolytic capacitors.
FEATURES
- up to 36 W continuous power
- meets DoE Level VI efficiency
- universal input voltage range
- compact size
- no load power consumption < 0.10 W
- over voltage and short circuit protections
- UL/cUL, TUV, and PSE safety approvals
- LED indicator
- custom designs available PART NUMBER KEY Base Number Reserved for Custom Configurations SDM36 - XX - UX - XXX - CXX DC Plug Type: XXX = See output plug options on page 5 for more details Output Voltage Input Cable: “Blank” = No Cable C = North America input cable (standard) CM = North America input cable (medical) 2 = Europe input cable AC Inlet Type: IEC320/C14 For more information, please visit the product page | For information on related products, view Dc Power Jacks
cui.com date 01/29/2018 │ page 2 of 6CUI Inc │ SERIES: SDM36-U │ DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description min typ max units voltage 90 264 Vac frequency 47 63 Hz current 1 A inrush current at 230 Vac, full load, 25°C, cold start 70 A leakage current 0.3 mA no load power consumption at 230 Vac 0.10 W OUTPUT parameter conditions/description min typ max units regulation 5 Vdc model all other models PROTECTIONS parameter conditions/description min typ max units over voltage protection output shut down 200 % over current protection output shut down, auto recovery 200 % short circuit protection output shut down, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output at 10 mA for 1 minute input to frame ground at 10 mA for 1 minute 4,000 2,000 Vac Vac isolation resistance input to output at 500 Vdc input to frame ground at 500 Vdc MΩ MΩ safety approvals Medical: UL/cUL, TUV ITE: PSE EMI/EMC FCC Part 15B Class B, CE MTBF as per Telcordia SR-332, 25°C 300,000 hours RoHS 2011/65/EU ENVIRONMENTAL parameter conditions/description min typ max units operating temperature 0 40 °C storage temperature -20 80 °C operating humidity non-condensing 20 80 % storage humidity non-condensing 10 90 % For more information, please visit the product page | For information on related products, view Dc Power Jacks
cui.com date 01/29/2018 │ page 3 of 6CUI Inc │ SERIES: SDM36-U │ DESCRIPTION: AC-DC POWER SUPPLY DC CORD MECHANICAL parameter conditions/description min typ max units dimensions 100 x 50 x 33 mm inlet plug IEC320/C14 weight without ac cord 170 g MECHANICAL DRAWING MODEL NO. CABLE CORD LENGTH SDM36-5-U UL2468, 16 AWG 1,500 mm ±30 SDM36-7.5-U UL2468, 18 AWG 1,500 mm ±30 SDM36-9-U UL2468, 18 AWG 1,500 mm ±30 SDM36-12-U UL2468, 18 AWG 1,500 mm ±30 SDM36-15-U UL2468, 18 AWG 1,500 mm ±30 SDM36-18-U UL2468, 20 AWG 1,500 mm ±30 SDM36-24-U UL2468, 20 AWG 1,500 mm ±30 Table 1 units: mm tolerance:±1.0 mm units: mm For more information, please visit the product page | For information on related products, view Dc Power Jacks
cui.com date 01/29/2018 │ page 4 of 6CUI Inc │ SERIES: SDM36-U │ DESCRIPTION: AC-DC POWER SUPPLY AC CORDS NORTH AMERICA (STANDARD) NORTH AMERICA (MEDICAL) units: mm EUROPE For more information, please visit the product page | For information on related products, view Dc Power Jacks
cui.com date 01/29/2018 │ page 5 of 6CUI Inc │ SERIES: SDM36-U │ DESCRIPTION: AC-DC POWER SUPPLY A CB A B C C A B Right Angle (R)Straight C A B Right Angle (R)Straight P5(-) P1(+) Standard EIAJ Locking USB Stripped & Tinned C A B 5.4±0.4 DC PLUG TYPE PART NUMBER KEY X X X Plug Code: X = Choose a code from the options below Plug Angle: “blank” = Straight R = Right Angle Plug Polarity: P = Center Positive N = Center Negative Plug Polarity Code Dimensions (mm) Plug Angle Center Pos. Center Neg. Option Type A B C Straight Right
- ● 5 Standard 5.5 2.1 9.5 ● ●
- ● 6 Standard 5.5 2.5 9.5 ● ●
- ● 7 Standard 3.5 1.35 9.5 ● ●
- ● 8 Standard 3.8 1.35 9.5 ● ●
- ● 9 Standard 3.8 1.05 9.5 ● ●
- ● 10 Locking 5.5 2.1 9.5 ● N/A
- ● 11 Locking 5.5 2.5 9.5 ● N/A N/A N/A ST Stripped & Tinned N/A N/A N/A N/A MUB USB Micro USB Type B ● N/A Note: 1. Contact CUI for additional plug options For more information, please visit the product page | For information on related products, view Dc Power Jacks
date 01/29/2018 │ page 6 of 6CUI Inc │ SERIES: SDM36-U │ DESCRIPTION: AC-DC POWER SUPPLY This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 01/29/2018 The revision history provided is for informational purposes only and is believed to be accurate.
REVISION HISTORY
For more information, please visit the product page | For information on related products, view Dc Power Jacks