cui.com date 06/27/2022 page 1 of 6 SERIES: SDM300G-U │ DESCRIPTION: AC-DC POWER SUPPLY MODEL output voltage output current output power ripple and noise1 efficiency level (Vdc) max (A) max (W) max (mVp-p) SDM300G-12-U 12 24.0 288 120 VI SDM300G-15-U 15 20.0 300 150 VI SDM300G-19-U 19 15.79 300 190 VI SDM300G-24-U 24 12.5 300 240 VI SDM300G-48-U 48 6.25 300 480 VI Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 μF multilayer ceramic and 47 μF low ESR electrolytic capacitors.
FEATURES
- GaN technology
- compact size
- 300 W power
- universal input (90~264 Vac)
- single regulated outputs
- over voltage, over current, over temperature and short circuit protections
- UL/cUL (60601), TUV
- level VI efficiency
- power factor correction
- custom designs available PART NUMBER KEY Base Number Reserved for Custom Configurations SDM300G - XX - U X - P219- CXX Output Voltage AC Inlet Type: IEC320/C14 Input Cable: “Blank” = No Cable C = North America input cable 2 = Europe input cable 3 = United Kingdom input cable 4 = Australia input cable 5 = China input cable 6 = South Korea input cable 7 = Brazil input cable 8 = South Africa input cable 9 = Japan input cable Additional Resources: Product Page | 3D Model
cui.com date 06/27/2022 │ page 2 of 6CUI Inc │ SERIES: SDM300G-U │ DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description min typ max units voltage 100 240 Vac frequency 50 60 Hz current 1.5 3.5 A inrush current at 240 Vac, full load, 25°C, cold start 150 A leakage current 0.1 mA no load power consumption at 115 & 230 Vac 0.5 W power factor at 115 & 230 Vac, full load 0.9 OUTPUT parameter conditions/description min typ max units regulation ±5 % PROTECTIONS parameter conditions/description min typ max units over voltage protection latch 150 % over current protection auto recovery 180 % short circuit protection auto recovery over temperature protection output shut down SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output at 10 mA for 1 minute input to ground at 10 mA for 1 minute 4,000 1,770 Vac Vac isolation resistance input to output at 500 Vdc input to ground at 500 Vdc MΩ MΩ safety approvals UL/cUL 60601, TUV, UKCA, CB EMI/EMC CE, FCC MTBF as per Telcordia SR-332, 25°C 300,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature 60°C max at 50% load, see derating curve -20 40 °C storage temperature -20 80 °C operating humidity non-condensing 20 80 % storage humidity non-condensing 10 90 % Additional Resources: Product Page | 3D Model
cui.com date 06/27/2022 │ page 3 of 6CUI Inc │ SERIES: SDM300G-U │ DESCRIPTION: AC-DC POWER SUPPLY MECHANICAL parameter conditions/description min typ max units dimensions 183.0 (L) x 85.0 (W) x 35.0 (H) mm dc output plug 6 pin housing weight 12, 15, 19 Vdc output models 24, 48 Vdc output models 1100 1000 g g MECHANICAL DRAWING units: mm tolerance: ±1.0 mm Front-View Top-View Side-View DERATING CURVES Additional Resources: Product Page | 3D Model
cui.com date 06/27/2022 │ page 4 of 6CUI Inc │ SERIES: SDM300G-U │ DESCRIPTION: AC-DC POWER SUPPLY DC CORD units: mm MODEL NO. CABLE CORD LENGTH SDM300G-12-U Black, UL2464, 16 AWG 1,000 mm ±50 SDM300G-15-U Black, UL2464, 16 AWG 1,000 mm ±50 SDM300G-19-U Black, UL2464, 16 AWG 1,000 mm ±50 SDM300G-24-U Black, UL2464, 16 AWG 1,200 mm ±50 SDM300G-48-U Black, UL2464, 18 AWG 1,200 mm ±50 Table 1 Output cable plug pin assignment Table 2 PIN ASSIGNMENT PIN OUTPUT VOLTAGE 12V/15V/19V 24V/48V P1 +Vout +Vout P2 +Vout NC P3 +Vout +Vout P4 -Vout -Vout P5 -Vout NC P6 -Vout -Vout Additional Resources: Product Page | 3D Model
cui.com date 06/27/2022 │ page 5 of 6CUI Inc │ SERIES: SDM300G-U │ DESCRIPTION: AC-DC POWER SUPPLY Table 2 AC Input Cord Length North America 1,830 mm ±30 Europe 1,830 mm ±30 United Kingdom 1,830 mm ±30 Australia 1,830 mm ±30 China 1,830 mm ±30 South Korea 1,830 mm ±50 Brazil 1,830 mm ±30 South Africa 1,830 mm ±50 Japan 1,830 mm ±30 AC CORD NORTH AMERICA EUROPE AUSTRALIA UNITED KINGDOM CHINA units: mm cord length SOUTH KOREA SOUTH AFRICA BRAZIL JAPAN Additional Resources: Product Page | 3D Model
date 06/27/2022 │ page 6 of 6CUI Inc │ SERIES: SDM300G-U │ DESCRIPTION: AC-DC POWER SUPPLY CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 06/27/2022 The revision history provided is for informational purposes only and is believed to be accurate.
REVISION HISTORY