SD10 MSYSTEM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 9

Technical content

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 1/9 Single Loop Controller Series BARGRAPH INDICATING ALARM (with 4-digit digital meter, LED bar indicator) Functions & Features

  • Panel designed to match the SC series controllers.
  • Displays a process variable in graphic bargraph of 101 LED segments
  • 3 input channels
  • Clear 4-digit digital meter
  • Provides max. 4 alarm contact outputs
  • LED brightness adjustments
  • IP55 front cover
  • Multi-color indicator (red, orange and green)
  • Scale plate is easily replaceable Typical Applications
  • Panel operation for small-scale instrumentation
  • Various alarm applications 144 (5.67) 72 (2.83) 274 (10.79) mm (inch)

ORDERING INFORMATION

Specify a code from below for each [1] through [10]. (e.g. SD10-RYGAA0A6Y-M2)

  • Use Ordering Information Sheet (No. ESU-6341) for the I/O codes, digital display range, decimal point position and alarm setpoint.
  • Bargraph range (Refer to 'SCALE PLATE') [1] BAR LED COLOR (INPUT 1) R: Red Y: Amber G: Green B: Blue 1: Multi-color (red, orange and green), (See ‘External View.’) [2] BAR LED COLOR (INPUT 2) Same color availability as Input 1 [3] BAR LED COLOR (INPUT 3) Same color availability as Input 1 [4] INPUT 1 Current A: 4 – 20 mA DC (Input resistance 10 Ω) Z: Specify current (See INPUT SPECIFICATIONS) Voltage 6: 1 – 5 V DC (Input resistance 1 MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) [5] INPUT 2 Same range availability as Input 1 [6] INPUT 3 Same range availability as Input 1 [7] DC OUTPUT 1 Y: Without Current A: 4 – 20 mA DC (Load resistance 550 Ω max.) D: 0 – 20 mA DC (Load resistance 550 Ω max.) Voltage 6: 1 – 5 V DC (Load resistance 10 kΩ min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [8] DC OUTPUT 2 Same range availability as DC Output 1 [9] DC OUTPUT 3 Same range availability as DC Output 1 [10] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) SPARE PARTS
  • Scale plate

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 2/9 GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP55; applicable to the front panel for single unit mounted according to the specified panel cutout Connection: M3.5 screw terminals (torque 1.0 N·m) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray), steel Setting: (Front button)

  • Scaled range
  • Alarm setpoint
  • LED brightness
  • Moving average
  • DC output fine adjustment
  • Others (Refer to the instruction manual for details) Isolation: Input 1 to input 2 to input 3 to supply output to DC output 1 to DC output 2 to DC output 3 to alarm output 1 to alarm output 2 to alarm output 3 to power to FG Display zero adjustment (bargraph): -19 to +19 % DC output zero adjustment: -19 to +19 % Display span adjustment (bargraph): 81 to 119 % DC output span adjustment: 81 to 119 % Scale plate: Flame resistant resin (white scale & characters on black base) H & L alarm output delay: 0 sec. (factory setting; fieldselectable between 0 and 15 sec. by 1 sec. increments) Setpoint adjustment HH [H setpoint] to 100 % H [L setpoint] to [HH setpoint] L [LL setpoint] to [H setpoint] LL 0 % to [L setpoint] Alarm deadband (hysteresis): 1 % ■ BARGRAPH 3 Bar-LEDs indicate scaled Input 1, 2 and 3 from 0 to 100 %. LED: 101 segments, 100 mm (3.94") height, 3.0 mm (.12") width Display range: 0 to 100 Number of digits: Max. 4 digits (including decimal point and negative sign) Divisions: 22 – 100 Engineering unit: max. 6 characters Bargraph display scale plate
  • Detachable structure
  • White characters on black base ■ DIGITAL DISPLAYS With the Input indication selector (IND) display Input 1, 2 and 3 scaling values. LED: Red; 4 digits; 10 mm (0.39") height, 24 mm (0.94") width Scaled range: -1999 to 0 to 9999 (Min. 3 significant digits) Minimum scale value: 100 (3 digits, the decimal point position disregarded) Overrange: The indicator blinks when the input is out of the range from -15 to +115 %. The indicator shows '----' when the value after scaling is out of the range. Decimal point position: 10–1, 10–2, 10–3 or none Zero indication: Higher-digit zeros are suppressed ■ LED BRIGHTNESS ADJUSTMENTS 3 levels of brightness available for the bargraph and the digital indicator. (except alarm and mode setting status LED) Read rate: 5/s Moving average sample number: 4 (factory setting; field selectable among 1, 2, 4, 8 or 16) SUPPLY OUTPUT Output voltage:

24 V DC ±10 % with no load

18 V DC min. at 20 mA Current rating: ≤ 22 mA DC ∙Shortcircuit protection Current limited: Approx. 30 mA INPUT SPECIFICATIONS ■ DC Current: 0 – 50 mA DC; input resistor incorporated M-system selects input resistance from the following values Max. signal (DC current at input 100 %) range: Input resistance value 39 mA or more, not more than 50 mA: 5.1 Ω 20 mA or more, less than 39 mA: 10 Ω 16 mA or more, less than 20 mA: 12 Ω 10 mA or more, less than 16 mA: 20 Ω 5 mA or more, less than 10 mA: 39 Ω 1 mA or more, less than 5 mA: 200 Ω Minimum span: 1 mA Offset: Max. 1.5 times span ■ DC Voltage: -10 – +10 V DC Input resistance: ≥ 1 MΩ Minimum span: 0.1 V Offset: Max. 1.5 times span OUTPUT SPECIFICATIONS ■ DC Voltage Choose output range from below. 0 – 1 V DC (Load resistance 2000 Ω min.) 0 – 10 V DC (Load resistance 20 kΩ min.) 0 – 5 V DC (Load resistance 10 kΩ min.) -10 – +10 V DC (Load resistance 20 kΩ min.) -5 – +5 V DC (Load resistance 10 kΩ min.) For details, refer to the Ordering Information Sheet. ■ Alarm Output: Relay contact

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 3/9 Rated load: 240 V AC @ 1 A (cos ø = 1)

30 V DC @ 1 A (resistive load)

Maximum switching voltage: 250 V AC or 30 V DC Maximum switching power: 250 VA or 60 W Minimum load: 5 V DC @ 10 mA Mechanical life: 2 × 107 cycles INSTALLATION Power consumption AC: ≤ 14 VA at 100 V ≤ 17 VA at 200 V ≤ 19 VA at 264 V

  • DC: ≤ 7.3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 5 to 90 %RH (non-condensing) Mounting: Panel flush mounting (high-density mounting in horizontal direction) Weight: 1.8 kg (4.0 lb) PERFORMANCE in percentage of span Accuracy: Input accuracy + output accuracy
  • Input accuracy: ±0.1%
  • Output accuracy: ±0.1 % DC output ±1 % ±1 digit (bargraph) ±0.1 % ±1 digit (digital indicator) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 90%, moving average sample number set to 4) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength:

1500 V AC @ 1 minute (Input 1 or Input 2 or input 3 or

supply output to DC output 1 or DC output 2 or DC output 3 to alarm output 1 or alarm output 2 or alarm output 3 to power to FG)

500 V AC @ 1 minute (Input 1 to Input 2 to input 3 to supply

output)

500 V AC @ 1 minute (DC output 1 to DC output 2 to DC

output 3)

500 V AC @ 1 minute (alarm output 1 to alarm output 2 to

alarm output 3)

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 4/9 SCALE PLATE

  • Type 1: 1.1 Scale Span < 1.3 Number of divisions: 22 to 25.9 Scale: Starts at 0, increments by 0.02 / 0.2 / 2 / 20 / 200. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Short, Medium, Short, Long (4 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 600 400 200 -200 -4000.2 -600 0.4 0.6 0.8 1.0 1.2 1.29 ■ WHAT MUST BE SPECIFIED WHEN ORDERING Please specify the bargraph scale range and engineering unit. The overvall scale plate design including the number of divisions, division line length, character font is determined by M-System. [Example] : Bargraph range 0 to 300 cm Bargraph scale range: 0 – 300 Engineering unit for the bargraph: cm ■ TYPES OF DIVISIONS Five (5) types of divisions are used depending upon the scale span, which determined by the following equation: Scale Span = (Max. range value – Min. range value) x 10n where n = integer (used to limit the calculated scale span to the minimum of 1.1, below 11.0.) The number of divisions is automatically determined by the scale span.
  • Type 2: 1.3 Scale Span < 2.0 Number of divisions: 26 to 39.9 Scale: Starts at 0, increments by 0.03 / 0.3 / 3 / 30 / 300. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Short, Medium, Short, Medium, Short, Long (6 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 0.3 0.6 0.9 1.2 1.5 1.8 0.6 0.3 -0.3 -0.6 -0.8 0.81.99 120 130

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 5/9 0.5 0.4 0.3 0.2 0.1 -0.1 -0.2 -0.3 -0.4 -0.5 100 200 300 400 500 550 10.9 Minimum Divisions Maximum Divisions Bipolar Scale

  • Type 5: 5.5 Scale Span < 11.0 Number of divisions: 27 .5 to 54.9 Scale: Starts at 0, increments by 0.01 / 0.1 / 1 / 10 / 100 / /1000. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Medium, Medium, Medium, Medium, Long (5 divisions repeated) [Example] : Bargraph range 0 to 300 cm (Type 4) Digital indicator range 0.00 to 6.75 m3 (Type 4) Left scale range: 0 – 300 Left scale unit (bargraph): cm Center and right bar scale: None 300 250 cm 200 150 100
  • Type 3: 2.0 Scale Span < 2.6 Number of divisions: 40 to 51.9 Scale: Starts at 0, increments by 0.05 / 0.5 / 5 / 50 / 500. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Short, Medium, Short, Medium, Short, Medium, Short, Medium, Short, Long (10 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 120 100 -50 -100 -120 0 0 0.5 1.5 2.59
  • Type 4: 2.6 Scale Span < 5.5 Number of divisions: 26 to 54.9 Scale: Starts at 0, increments by 0.05 / 0.5 / 5 / 50 / 500. Min. and max. values indicated. 4 digits including negative sign and decimal point. Division lines: Long, Medium, Medium, Medium, Medium, Long (5 divisions repeated) Minimum Divisions Maximum Divisions Bipolar Scale 250 200 150 100 -50 -100 -150 -200 -250 0 0 0.5 1.5 2.5 3.5 4.5 5.49 100 150 200 250 260

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 6/9 EXTERNAL VIEW 1 6 7 3 4 5 1 . Digital meter 2. Digital meter Selector LED (Displays which of the 3 inputs value is indicating) 3. Input 1 bargraph meter 4. Input 2 bargraph meter 5. Input 3 bargraph meter 6. Alarm indicator 7 . Mode setting status LED 8. Input indication selector (IND) 9. Mode selector (M) 10. Manual operation button (UP) 11 . Acceleration button (FAST) (Acclerates the operation by pressing simultaneously with UP or DOWN button) 12. Manual operation button (DOWN) HH Setpoint H Setpoint L Setpoint LL Setpoint PV Indicator

  • Bar Color Pattern orange orange green orange Input < L L < Input < H H < Input green red H L EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 144 (5.67) 164 (6.46) MOUNTING BRACKET 137.5 (5.41) TERMINAL COVER 52–M3.5 SCREW

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 7/9 PANEL CUTOUT unit: mm 138 68 [68+72×(n - 1)] +0.7 Panel thickness 2.3 – 20 138 ■ PANEL CUTOUT unit: mm

  • Single mounting • Clustered mounting n = number of units ■ CAUTION
  • Degree of protection, IP55 is applicable to the front panel of the unit with single mounting according to the specified panel cutout. Ensure that there is no compromise in the unit's protection against water and dust after installation.
  • Install the unit to vertical panel so that its digital meter is at the upper side. Installing by other direction will cause degradation of life span or performance due to rise of the internal temperature.
  • Ensure that there is sufficient space for ventilation inside a panel. Do not install above the devices that generate high temperature such as heaters, transformers or resistors. Observe at the minimum of 30 mm (1.2”) in all directions for maintenance purpose.

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 8/9 SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Bargraph LED CH1 (IND) INPUT 1 (Ai1) INPUT 2 (Ai2) INPUT 3 (Ai3) SUPPLY OUTPUT 29 + 30 –

24 V DC

(M) (UP) (FAST) (DOWN) 3 + 4 – DC OUTPUT 1 (Ao1)* U(+) V(–) 26 FG

2 HHa1

Hc1, HHc1 HHb1 Ha1 HH OUTPUT 1 H OUTPUT 1

28 LLa1

Lc1, LLc1 LLb1 La1 LL OUTPUT 1 L OUTPUT 1 CH2 5 + 6 – DC OUTPUT 2 (Ao2)*

17 HHa2

Hc2, HHc2 HHb2 Ha2

21 LLa2

Lc2, LLc2 LLb2 La2 CH3 7 + 8 –

11 HHa3

Hc3, HHc3 HHb3 Ha3

39 LLa3

Lc3, LLc3 LLb3 La3 HH OUTPUT 2 H OUTPUT 2 LL OUTPUT 2 L OUTPUT 2 DC OUTPUT 3 (Ao3)* HH OUTPUT 3 H OUTPUT 3 LL OUTPUT 3 L OUTPUT 3 Isolation Isolation Isolation Digital Meter IsolationIsolation Output Circuit IsolationIsolation Output Circuit IsolationIsolation Output Circuit POWER Input A/D Converter Input A/D Converter Input A/D Converter Digital Computation CONNECTION (2-Wire transmitter) B C Supply output Input 1, 2 or 3 (Current input only) * Not available for output code /Y 2-Wire transmitter ** Not applicable to smart transmitters

MODEL: SD10 http://www.m-system.co.jp/ SD10 SPECIFICATIONS ES-6341 Rev.3 Page 9/9 Specifications are subject to change without notice.