SCT016S YHDC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

Split core current transformer ModelğSCT016S Characteristic: Compatible to foreign products completely, built-in TVS. Purpose: Applicable for the current measuring monitoring and protection of AC motor, lighting equipment and air compressor. Technical indicators: Hanging installation, leading wire 50cm Material of core: Silicon steel sheet Fire resistance property: UL94-V0 Work voltage:660V Work temperature:-25℃~+60℃ Storage temperature:-30℃~+90℃ Frequency range:50Hz~60Hz Dielectric strength:3.5KV 50Hz 1min Electric parameter: Outline size diagram(in mm): Characteristic curve in different load volt-ampere: Wiring diagram: Rated input(rms) Max. Input Rated output Turns ratio Accuracy Linearity Phase error max:Sampling resistance Weight 150 200 1:3000 ≤0.2 A A mA Ω g www.yhdc.com Email :yhdc@yhdc.com TVS:Transient voltage suppressor,Current output type K k lL TVS (Black) (White) Front view Side view 29.5 Φ16 Opening angle 180° k l K L l ±0.5 ±0.5 ±0.5 ±0.3